Customer Class File Number
Cooper Crouse-Hinds GmbH
Neuer Weg Nord 49
Eberbach
Baden-Württemberg
Germany
69412
3428-03
FIXTURES AND FITTINGS - For Hazardous Locations
240700

(


Ex em ib IIC

Class I, Zone 1, AEx em ib IIC

Class I, Division 2, Groups A, B, C and D.

Class II, Division 2, Groups E, F and G

Permanently installed exit sign

Model(s)Voltage (VAC)Current (mA)Power (VA)EnclosureVoltage (VDC)
Type Ex-Lite Z, Type  Ex-Lite Z E110‑277546IP66
110‑250

Temperature code is T6, T5 or T4 depending on the maximum ambient temperature (40°C or 50°C) and models 

Ex de IIC,
Class II, Division 1, Groups E, F and G

Fluorescent Luminaire

Model(s)Voltage (VAC)Frequency (Hz)TypeIngress Protection CodeTemperature CodeAmbient Temp. Range (°C)Voltage (VDC)
eLLK92 2217/U240, eLLK92 4232/ U240, eLLS08 2217/ U240, eLLS08 4232/ U240, eLLM 92 4232/ U240, eLLM 92 2217/ U240120‑24050‑604XIP66T4‑25 to +55
120‑240
eLLB20 2217/U240, eLLB20 4232/U240120‑24050‑604XIP66T4‑25 to +55
120‑240

Ex d e ib m IIC
Class II, Division 1, Groups E, F and G

Model(s)Voltage (VAC)Frequency (Hz)TypeIngress Protection CodeTemperature CodeAmbient Temp. Range (°C)
eLLK92 NIB 22 17 / U120, eLLK92 NIB 4232/ U120, eLLS 08 NIB 22 17/ U120, eLLS 08 NIB 42 32 / U12012050‑604XIP66T4‑25 to +55
eLLK92 NIB 22 17 / U240, eLLK92 NIB 4232/ U240, eLLS 08 NIB 22 17/ U240, eLLS 08 NIB 42 32 / U24024050‑604XIP66T4‑25 to +55
eLLB20 NIB 2217/U120, eLLB20 NIB 4232/U12012050‑604XIP66T4‑25 to +55
eLLB20 NIB 2217/U240, eLLB20 NIB 4232/U24024050‑604XIP66T4‑25 to +55

Ex d e ib m IIC ;
Class II, Division 1, Groups E, F and G

Model(s)Voltage (VAC)Frequency (Hz)TypeIngress Protection CodeTemperature CodeAmbient Temp. Range (°C)Voltage (VDC)
eLLK92 2217/U240, eLLK92 4232/ U240, eLLS08 2217/ U240, eLLS08 4232/ U240, eLLM 92 4232/ U240, eLLM 92 2217/ U240120‑24050‑604XIP66T4‑25 to +55
120‑240
eLLB20 2217/U240, eLLB20 4232/U240120‑24050‑604XIP66T4‑25 to +55
120‑240

Ex d e ib m IIC ;
Class II, Division 1, Groups E, F and G

Model(s)Voltage (VAC)Frequency (Hz)TypeIngress Protection CodeTemperature CodeAmbient Temp. Range (°C)
eLLK92 NIB 22 17 / U120, eLLK92 NIB 4232/ U120, eLLS 08 NIB 22 17/ U120, eLLS 08 NIB 42 32 / U12012050‑604XIP66T4‑25 to +55
eLLK92 NIB 22 17 / U240, eLLK92 NIB 4232/ U240, eLLS 08 NIB 22 17/ U240, eLLS 08 NIB 42 32 / U24024050‑604XIP66T4‑25 to +55
eLLB20 NIB 2217/U120, eLLB20 NIB 4232/U12012050‑604XIP66T4‑25 to +55
eLLB20 NIB 2217/U240, eLLB20 NIB 4232/U24024050‑604XIP66T4‑25 to +55

Ex nA II T4;
Class II, Division 1, Groups E, F and G

Model(s)Voltage (VAC)Frequency (Hz)Lamp Wattage (W)TypeIngress Protection CodeTemperature CodeAmbient Temp. Range (°C)
nLLK 98 4232 / UNV120‑27750‑60324XIP65T4‑20 to +40
(optional) 25 to +55
nLLK 98 2217 / UNV120‑27750‑60174XIP65T4‑20 to +40
(optional ) ‑25 to +55
nLLK 98 2217 / 34734760174XIP65T4‑20 to +40
(optional) ‑25 to +55
nLLK 98 4232 / 34734760324XIP65T4‑20 to +40
(optional) 25 to +55

Ex de mb IIC T4 Gb ;

Class II, Division 1, Groups E, F and G.

Ex tb IIIC T80???C Db

Model(s)TypeIngress Protection CodeAmbient Temp. Range (°C)Voltage (VAC)Frequency (Hz)Voltage (VDC)
eLLK 92 LED 400, eLLK 92 LED 8004XIP66‑25 to +45110‑25450‑60
110‑250

 Luminaires are equipped with ballast type:

-           EVG09 218 for model eLLK 92 LED 400 

-           EVG09 236 for model eLLK 92 LED 800

Ex de mb ib IIC T4 Gb ;

Class II, Division 1, Groups E, F and G.

Ex tb IIIC T80???C Db

Model(s)TypeIngress Protection CodeVoltage (VAC)Frequency (Hz)Ambient Temp. Range (°C)
eLLK 92 LED 400 NIB, eLLK 92 LED 800 NIB4XIP66220‑25450‑60‑25 to +45
110‑127

Luminaires are equipped with ballast type:

-           VE/EVG05 218(-1) for model eLLK 92 LED 400 NIB

-           EVG09 236 for model eLLK 92 LED 800 NIB

Ex nA nC de IIC T4 Gc ;

Class II, Division 2, Groups E, F and G.

Ex tc IIIC T80???C Dc

Model(s)Lamp Wattage (W)TypeIngress Protection CodeVoltage (VAC)Frequency (Hz)Ambient Temp. Range (°C)
nLLK 13 2214 / UNV144XIP66120‑22750‑60‑25 to +50
nLLK 13 4228 / UNV284XIP66120‑22750‑60‑25 to +50
nLLK 13 5235 / UNV354XIP66120‑22750‑60‑25 to +40

 Luminaires are equipped with ballast type:

-           EVG09 T5 HE for model nLLK 13 xxxx /UNV

Ex e ib mb IIC T* Gb
Class I, Zone 1, AEx e ib mb IIC T* Gb
Ex tb IIIC T80°C Db
Zone 21, AEx tb IIIC T80°C Db

Permanently installed exit sign

Model(s)Voltage (VAC)Current (mA)Power (W)EnclosureVoltage (VDC)
Type Ex-Lite Z, Type Ex-Lite ZR110‑227353.6IP66
455 110‑250

Temperature code is T6, T5 or T4 depending on the maximum ambient temperature and models.

Electrical parameters and Temperature code:

Type

Voltage
[V]

AC / DC

Frequency
[Hz]

Ambient temperature

Temperature class /
surface temperature

Ex-Lite  Z/ZR

110 - 277

AC

50 / 60

-20 °C ≤ Ta ≤ 40 °C 

T6 / T80 °C 

-20 °C ≤ Ta ≤ 50 °C 

T5 / T80 °C 

110 - 250

DC

---

-20°C  ≤ Ta ≤ 40°C 

T6 / T80°C 

-20°C  ≤ Ta ≤ 50°C 

T5 / T80°C 

Ex e ib mb IIC T* Gb
Class I, Zone 1, AEx e ib mb IIC T* Gb
Ex tb IIIC T80°C Db
Zone 21, AEx tb IIIC T80°C Db

Model(s)Voltage (VAC)Current (mA)Power (W)EnclosureVoltage (VDC)
Type Ex-Lite ZE, Type ZER110‑227353.6IP66
455 110‑250

Temperature code is T6, T5 or T4 depending on the maximum ambient temperature and models.

Electrical parameters and Temperature code:

Type

Voltage
[V]

AC / DC

Frequency
[Hz]

Ambient temperature

Temperature class /
surface temperature

Ex-Lite ZE/ZER 

110 - 277

AC

50 / 60

-20 °C ≤ Ta ≤ 40 °C 

T5 / T80 °C 

-20 °C ≤ Ta ≤ 50 °C 

T4 / T80 °C 

110 - 250

DC

---

-20°C  ≤ Ta ≤ 40°C 

T5 / T80°C 

-20°C  ≤ Ta ≤ 50°C 

T4 / T80°C 

/rlm