Customer Class File Number
ERICO International Corporation
34600 Solon Rd
Solon
Ohio
United States
44139
5851-01
WIRES - Appliance
090005_0_000

To the requirements of
CSA C22.2 NO. 210-15

Flexible Insulated Busbar Type Eriflex Flexiibar

Model(s)AWM ClassAWM GroupTemperature (°C)Voltage (V)Insulation Type/ Minimum Average Thickness (mm)Notes
Flexible Insulated Busbar Type Eriflex FlexiibarIA/B105 Dry, 75 Wet1000 PVC /1.071, 2, 3, 4

Flexible Insulated Busbar Type Eriflex Flexiibar Advanced

Model(s)AWM ClassAWM GroupTemperature (°C)Voltage (V)Insulation Type/ Minimum Average Thickness (mm)Notes
Flexible Insulated Busbar Type Eriflex Flexiibar AdvancedIA/B60/80/90/105Dry/115Dry30/150/300/6001000TPE/1.521, 2, 4, 8, 9, 10

*Number of laminates times width of laminate (mm) times thickness of laminates (mm).

Insulated Braided Conductor (Ibs, Ibsb/Ibsbr)

Model(s)AWM ClassAWM GroupTemperature (°C)Voltage (V)Insulation Type/ Minimum Average Thickness (mm)Notes
Insulated Braided Conductor (Ibs, Ibsb/Ibsbr)IA/B105 Dry, 75 Wet1000PVC (1.07mm)3, 4, 5, 6, 7

*Number of laminates times width of laminate (mm) times thickness of laminates (mm).

Insulated Braided Conductor (Ibs, Ibsb/Ibsbr Advanced)

Model(s)AWM ClassAWM GroupTemperature (°C)Voltage (V)Insulation Type/ Minimum Average Thickness (mm)Notes
Insulated Braided Conductor (Ibs, Ibsb/Ibsbr Advanced)IA/B60/80/90/105 Dry, 115 Dry30/150/300/6001000TPE/1.524, 5, 6, 7, 8, 9,10

*Number of laminates times width of laminate (mm) times thickness of laminates (mm).

To the requirements of
CSA C22.2 NO. 210-15 (R2020) (Fourth Edition)

Flexible Insulated Busbar (FLEXIBAR), with a PVC insulation, black colour only.

Model(s)ClassGroupTemperatureVoltage (V)Flame Classification
Part (A): AWMIA/B105CDry/75CWet1000FT1

Insulated Braided Conductor Flat or Round (IBS), with a PVC insulation, black colour only.

Model(s)ClassGroupTemperatureVoltage (V)Flame Classification
Part (B): AWMIA/B105CDry/75CWet1000FT1

Insulated Braided Conductor for Circuit Breakers (IBSB/IBSBR), with a PVC insulation, black colour only.

Model(s)ClassGroupTemperatureVoltage (V)Flame Classification
Part (C): AWMIA/B105CDry/75CWet1000FT1

Flexible Insulated Busbar (FLEXIBAR Advanced), with TPE insulation, all colours except clear and translucent.

Model(s)ClassGroupTemperatureVoltage (V)Flame Classification
Part (D): AWMIA/B60/80/90/105/115CDry30/150/300/600/1000FT1, FT2, VW‑1

Insulated Braided Conductor Flat or Round (IBS Advanced), with TPE insulation, black colour only.

Model(s)ClassGroupTemperatureVoltage (V)Flame Classification
Part (E): AWMIA/B60/80/90/105/115CDry30/150/300/600/1000FT1, FT2, VW‑1

Insulated Braided Conductor for Circuit Breakers (IBSB/IBSBR Advanced), with TPE insulation, black colour only.

Model(s)ClassGroupTemperatureVoltage (V)Flame Classification
Part (F): AWMIA/B60/80/90/105/115CDry30/150/300/600/1000FT1, FT2, VW‑1


Notes:  For specific details see certification report.

  1. The insulated busbars supplied in lengths of up to 4 meters.
  2. Conductor composition consists of 2-12 laminates (tinned or bare copper or nickel coated) with each strip having a thickness of 0.5mm/0.8mm/1.0mm and a width of 9mm-120mm.
  3. PVC insulated (black colour only).
  4. Flame classification: FT1.
  5. The Insulated Braided Conductors supplied in lengths from 230mm to 5000mm.
  6. Conductors consist of braided strands 0.15mm in diameter (tinned or bare copper or nickel coated) with cross sections of 25mm2 to 240mm2
  7. Flat or Round construction.
  8. Flame classification FT2.
  9. Flame classification VW-1.
  10. All colours except clear and translucent.