Customer Class File Number
SEA-USA Inc.
10850 NW 21 St., Unit 160
Miami
Florida
United States
33172
6711-01
DOOR OPERATING UNITS - Door Operating Units
251278

Last Updated:

June 21, 2019 (Replaces: June 12, 2019)

To the requirements of
CSA C22.2 NO. 247:14

Permanently Connected, Grounded Outdoor Use, Residential or Commercial/Industrial, Motorized Operated Vehicular Sliding Gate Operator

Lepus

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Rated Weight (lbs)Length (Ft.)
Lepus Rack1201 ph50/603.2Maximum: 2000/Minimum: 650Maximum: 37/Minimum: 12

Door Operator Classes per UL325: I, II and III 

Operating Controller: See note 1

Entrapment protection: A, B1, C

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it's to be intended always as primary entrapment protection.

Notes:
1) The above listed models, 120Vac: Lepus, Taurus and Sea Gear are intended for use with controllers, model: Gate 1 DG.

Lepus

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Length (Ft.)Rated Weight (lbs)
Lepus Rack Plus1201 ph50/602.45Maximum: 37/Minimum: 12Maximum: 2800/Minimum: 900

Door Operator Classes per UL325: I, II, III and IV 

Operating Controller: See note 1

Entrapment protection: A, B1, C

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it's to be intended always as primary entrapment protection.

Notes:
1) The above listed models, 120Vac: Lepus, Taurus and Sea Gear are intended for use with controllers, model: Gate 1 DG.

Lepus

ModelsVoltage (VAC)Current (A)Rated Weight (lbs)Length (Ft.)
Lepus Box1203.2Maximum: 1200/Minimum: 400Maximum: 40/Minimum: 14

Door Operator Classes per UL325: I, II and III  

Operating Controller: See note 1

Entrapment protection: A, B1, C

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it's to be intended always as primary entrapment protection.

Notes:
1) The above listed models, 120Vac: Lepus, Taurus and Sea Gear are intended for use with controllers, model: Gate 1 DG.

Lepus

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Rated Weight (lbs)Length (Ft.)
Lepus Box Plus1201 ph50/602.45Maximum: 2000/Minimum: 650Maximum: 40/Minimum: 14

Door Operator Classes per UL325: I, II, III and IV 

Operating Controller: See note 1

Entrapment protection: A, B1, C

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it's to be intended always as primary entrapment protection.

Notes:
1) The above listed models, 120Vac: Lepus, Taurus and Sea Gear are intended for use with controllers, model: Gate 1 DG.

Taurus

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Rated Weight (lbs)Length (Ft.)
Taurus Chain1201 ph50/601.8Maximum: 800/Minimum: 250Maximum: 25/Minimum: 8
Taurus Rack1201 ph50/601.8Maximum: 800/Minimum: 250Maximum: 25/Minimum: 8

Door Operator Classes per UL325: I, II and III

Operating Controller: See note 1

Entrapment protection: A, B1

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it's to be intended always as primary entrapment protection.

Notes:
1) The above listed models, 120Vac: Lepus, Taurus and Sea Gear are intended for use with controllers, model: Gate 1 DG.

Taurus

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Length (Ft.)Rated Weight (lbs)
Taurus Box 9001201 ph50/601.8Maximum: 25/Minimum: 8Maximum: 900/Minimum: 300

Door Operator Classes per UL325: I, II, III and IV 

Operating Controller: See note 1

Entrapment protection: A, B1

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it's to be intended always as primary entrapment protection.

Notes:
1) The above listed models, 120Vac: Lepus, Taurus and Sea Gear are intended for use with controllers, model: Gate 1 DG.

Sea Gear

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Rated Weight (lbs)Length (Ft.)
Sea Gear1201 ph50/605.6Maximum: 7000/Minimum: 500Maximum: 70/Minimum: 23

Door Operator Classes per UL325: I, II, III and IV 

Operating Controller: See note 1

Entrapment protection: A, B1

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it's to be intended always as primary entrapment protection.

Notes:
1) The above listed models, 120Vac: Lepus, Taurus and Sea Gear are intended for use with controllers, model: Gate 1 DG.

Permanently Connected, Grounded, Outdoor Use, Residential or Commercial/Industrial, Motorized Operated Vehicular Swing Gate Operator

Libra Family

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Rated WeightLength (m)
Libra Mini Tank1201 ph50/603Maximum: 400 KG/Minimum: 80 KGMaximum: 3/Minimum: 2
Libra Half Tank1201 ph50/603Maximum: 700 KG/Minimum: 80 KGMaximum: 7/Minimum: 2

Door Operator Classes per Section 31 of UL 325: I, II and III 

Operating Controller: See Note 1 

Entrapment protection type: A  or C  and  B1 or B2 

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it?s to be intended always as primary entrapment protection.

Notes:

  1. The above listed models Family, 120Vac: Libra, Lyra and Field are intended for use with controllers, models: Gate 1 DG, Gate 2 DG.
  2. The above listed models Family, 24Vdc: Field for use with controllers, models: User 1 DG and User 2 DG Model Family: Joint Hydro are complete operator system with integral controls

Libra Family

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Rated WeightLength (m)
Libra Full Tank1201 ph50/603Maximum: 1000 KG/Minimum: 80 KGMaximum: 7/Minimum: 2
Libra Super Full Tank1201 ph50/605.6Maximum: 1800 KG/Minimum: 80 KGMaximum: 9/Minimum: 2

Door Operator Classes per Section 31 of UL 325: I, II, III and IV 

Operating Controller: See Note 1 

Entrapment protection type: A  or C  and  B1 or B2 

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it?s to be intended always as primary entrapment protection.

Notes:

  1. The above listed models Family, 120Vac: Libra, Lyra and Field are intended for use with controllers, models: Gate 1 DG, Gate 2 DG.
  2. The above listed models Family, 24Vdc: Field for use with controllers, models: User 1 DG and User 2 DG Model Family: Joint Hydro are complete operator system with integral controls

Lyra Family

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Rated WeightLength (m)
Lyra1201 ph50/602.45Maximum: 800 KG/Minimum: 80 KGMaximum: 4/Minimum: 2
Lyra Compact1201 ph50/602.45Maximum: 800 KG/Minimum: 80 KGMaximum: 4/Minimum: 2
Lyra Super Compact1201 ph50/602.45Maximum: 1200 KG/Minimum: 80 KGMaximum: 5/Minimum: 2

Door Operator Classes per Section 31 of UL 325: I, II and III 

Operating Controller: See Note 1 

Entrapment protection type: A  or C  and  B1 or B2 

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it?s to be intended always as primary entrapment protection.

Notes:

  1. The above listed models Family, 120Vac: Libra, Lyra and Field are intended for use with controllers, models: Gate 1 DG, Gate 2 DG.
  2. The above listed models Family, 24Vdc: Field for use with controllers, models: User 1 DG and User 2 DG Model Family: Joint Hydro are complete operator system with integral controls

Lyra Family

ModelsPhaseVoltage (VAC)Frequency (Hz)Current (A)Rated WeightLength (m)
Lyra regular1 ph230501.2Maximum: 1200 KG/Minimum: 80 KGMaximum: 5/Minimum: 2
Lyra Maxi1 ph230501.4Maximum: 1200 KG/Minimum: 80 KGMaximum: 5/Minimum: 2

Door Operator Classes per Section 31 of UL 325: I, II, III and IV 

Operating Controller: See Note 1 

Entrapment protection type: A  or C  and  B1 or B2 

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it?s to be intended always as primary entrapment protection.

Notes:

  1. The above listed models Family, 120Vac: Libra, Lyra and Field are intended for use with controllers, models: Gate 1 DG, Gate 2 DG.
  2. The above listed models Family, 24Vdc: Field for use with controllers, models: User 1 DG and User 2 DG Model Family: Joint Hydro are complete operator system with integral controls

Field

ModelsVoltage (VDC)Current (A)Rated WeightLength (m)
Field245Maximum: 600 KG/Minimum: 80 KGMaximum: 3.5/Minimum: 2

Door Operator Classes per Section 31 of UL 325: I, II and III

Operating Controller: See Note 2

Entrapment protection type: A  or C  and  B1 or B2 

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it?s to be intended always as primary entrapment protection.

Notes:

  1. The above listed models Family, 120Vac: Libra, Lyra and Field are intended for use with controllers, models: Gate 1 DG, Gate 2 DG.
  2. The above listed models Family, 24Vdc: Field for use with controllers, models: User 1 DG and User 2 DG Model Family: Joint Hydro are complete operator system with integral controls

Joint Family

ModelsVoltage (VAC)PhaseFrequency (Hz)Current (A)Rated WeightLength (m)
Joint Hydro1201 ph50/602.5Maximum: 500 KG/Minimum: 80 KGMaximum: 4/Minimum: 2

Door Operator Classes per Section 31 of UL 325: I, II, III and IV 

Operating Controller: See Note 1

Entrapment protection type: A  or C  and  B1 or B2 

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it?s to be intended always as primary entrapment protection.

Notes:

  1. The above listed models Family, 120Vac: Libra, Lyra and Field are intended for use with controllers, models: Gate 1 DG, Gate 2 DG.
  2. The above listed models Family, 24Vdc: Field for use with controllers, models: User 1 DG and User 2 DG Model Family: Joint Hydro are complete operator system with integral controls

Control units for use with doors and gates openers, permanently connected, grounded, outdoor use type 3R enclosure

ModelsInput Voltage (VAC)PhaseInput Frequency (Hz)Input Current (A)Output Voltage (VDC)Output Current (A)
Part A: User 1 DG Maxi1201 ph50/60 1.52410
Part B: User 1 DG1201 ph50/60 1.5245

Openers reference report: 

CSA Report 2367093

CSA Report 2520910

Note: Those control unit shall be use only with products listed under M.C.251278 , CSA report 2367093 and 2520910. Refer to the openers certification report for details on controller and opener allow combination.

ModelsInput Voltage (VAC)PhaseInput Frequency (Hz)Output Voltage (VDC)Input Current (A)Output Current (A)
Part C: User 2 DG (Hydro)1201 ph50/60 2422 x 3A (2 motors)
Part D: User2 DG All-in1201 ph50/60 2422 x 3A (2 motors)

Openers reference report: 

CSA Report 2367093

CSA Report 2520910

Note: Those control unit shall be use only with products listed under M.C.251278 , CSA report 2367093 and 2520910. Refer to the openers certification report for details on controller and opener allow combination.

ModelsInput Voltage (VAC)Input Frequency (Hz)Output Voltage (VAC)PhaseInput Current (A)Output Current (A)
Part E: Gate 1 DG12050/60 120Output: 1 ph
Input: 1 ph2.82.5
Part F: Gate 2 DG12050/60 120Output: 1 ph
Input: 1 ph52 x 2.5A ( 2 motors)

Openers reference report: 

CSA Report 2367093

CSA Report 2520910

Note: Those control unit shall be use only with products listed under M.C.251278 , CSA report 2367093 and 2520910. Refer to the openers certification report for details on controller and opener allow combination.

/mk