Customer Class File Number
SEA-USA Inc.
10850 NW 21 St., Unit 160
Miami
Florida
United States
33172
6711-01
DOOR OPERATING UNITS - Door Operating Units
251278

TO THE REQUIRMENETS OF CSA 22.2 No.247-14

  • Permanently Connected, Grounded Outdoor Use, Residential or Commercial/Industrial, Motorized Operated Vehicular Sliding Gate Operator, Models Family: Lepus, Taurus, Sea Gear; rated as following:

Models Family

Electrical Ratings

Door Operator Classes per UL325

Operating Controller

Operated Door

Entrapment protection TYPE#

 

Weight max. (Lbs)

 

Weight min. (Lbs)

 

Length max. (Feet)

 

Length min.

(Feet)

Part A ? Lepus:

 

 

Lepus Rack

120Vac, 1 ph, 50/60Hz, 3.2Amps

I, II and III

See Note 1

2000

650 

37

 12

A,B1,C 

Lepus Rack Plus

120Vac, 1 ph, 50/60Hz, 2.45Amps

I, II, III and IV

See Note 1

2800

 900

37

12 

 A,B1,C 

Lepus Box

120Vac, 3.2Amps

I, II and III

See Note 1

1200

 400

40

 14

A,B1,C  

Lepus Box Plus

120Vac, 1 ph, 50/60Hz, 2.45Amps

I, II, III and IV

See Note 1

2000

 

650 

40

 14

A,B1,C  

Part B ? Taurus:

 

 

Taurus Chain

120Vac, 1 ph, 50/60Hz, 1.8A

I, II and III

See Note 1

800

250 

25

 8

A,B1   

Taurus Rack

120Vac, 1 ph, 50/60Hz, 1.8A

I, II and III

See Note 1

800

 250

25

 8

A,B1   

Taurus Box 900

120Vac, 1 ph, 50/60Hz, 1.8A

I, II, III and IV

See Note 1

900

300 

25

 8

 A,B1  

Part C:

 

 

Sea Gear

120Vac, 50/60Hz, 1ph, 5.6Amps

I, II, III and IV

See Note 1

7000

 500

70

 23

 A,B1  

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it?s to be intended always as primary entrapment protection.


Notes:
1) The above listed models, 120Vac: Lepus, Taurus and Sea Gear are intended for use with controllers, model: Gate 1 DG.

 

  • Permanently Connected, Grounded, Outdoor Use, Residential or Commercial/Industrial, Motorized Operated Vehicular Swing Gate Operator, Models Family: Libra and Lyra, Field , Joint, rated as following:

Models Family

Electrical Ratings

Door Operator Classes per Section 31 of UL 325

Operating Controller

Operated Door

Entrapment protection TYPE#

Weight max. (kg)

 

Weight min. (kg)

 

Length max. (m)

 

Length min.(m)

Part A ? Libra Family

Libra Mini Tank

120Vac, 1 ph, 50/60Hz, 3.0 A

I, II and III

See Note 1

400

80

3.0

2.0

A  or C  and  B1 or B2

Libra Half Tank

120Vac, 1 ph, 50/60Hz, 3.0 A

I, II and III

See Note 1

700

80

7.0

2.0

A  or C  and  B1 or B2

Libra Full Tank

120Vac, 1 ph, 50/60Hz, 3.0 A

I, II, III and IV

See Note 1

1.000

80

7.0

2.0

A  or C  and  B1 or B2

Libra Super Full Tank

120Vac, 1 ph, 50/60Hz, 5.6Amps

I, II, III and IV

See Note 1

1.800

80

9.0

2.0

A  or C  and  B1 or B2

Part B ? Lyra Family

Lyra

120Vac, 1 ph, 50/60Hz, 2.45A

I, II and III

See Note 1

800

80

4.0

2.0

A  or C  and  B1 or B2

Lyra Compact

120Vac, 1 ph, 50/60Hz, 2.45A

I, II and III

See Note 1

800

80

4.0

2.0

A  or C  and  B1 or B2

Lyra Super Compact

120Vac, 1 ph, 50/60Hz, 2.45A

I, II and III

See Note 1

1.200

80

5.0

2.0

A  or C  and  B1 or B2

Lyra regular

230Vac, 1 ph, 50Hz, 1.2A

I, II, III and IV

See Note 1

1.200

80

5.0

2.0

A  or C  and  B1 or B2

Lyra Maxi

230Vac, 1 ph, 50Hz, 1.4A

I, II, III and IV

See Note 1

1.200

80

5.0

2.0

A  or C  and  B1 or B2

Part C - Field

24 Vdc, 5.0  A

I, II, III

See note 2

600

80

3.5

2.0

A  or C  and  B1 or B2

PART D- Joint Family

Joint Hydro

120 Vac, 1 ph, 50/60Hz,  2.5 A

I, II, III and IV

See note 1

500

80

4.0

2.0

A  or C  and  B1 or B2

# Minimum n.2 independent system shall be provided; Entrapment protection system Type A or C shall be always provided in combination with an entrapment protection type B1 or B2.

Note: Type A entrapment protection it?s to be intended always as primary entrapment protection.


Notes:

  1. The above listed models Family, 120Vac: Libra, Lyra and Field are intended for use with controllers, models: Gate 1 DG, Gate 2 DG.

  2. The above listed models Family, 24Vdc: Field for use with controllers, models: User 1 DG and User 2 DG Model Family: Joint Hydro are complete operator system with integral controls

  • Control units for use with doors and gates openers, permanently connected, grounded, outdoor use type 3R enclosure, rated as following:

Model

Ratings Input

Output

Openers reference report

Part A

 

 

CSA Report 2367093

CSA Report 2520910

 

  User 1 DG Maxi

120Vac, 1 ph, 50/60Hz, 1.5A

24Vdc, 10A

Part B

 

 

  User 1 DG

120Vac, 1 ph, 50/60Hz, 1.5A

24Vdc, 5A

Part C

 

 

  User 2 DG (Hydro)

120Vac, 1 ph, 50/60Hz, 2A

24Vdc, 2 x 3A  (2 motors)

Part D

 

 

  User2  DG All-in

120Vac, 1 ph, 50/60Hz, 2A

24Vdc, 2 x 3A  (2 motors)

Part E

 

 

  Gate 1 DG

120Vac, 1 ph, 50/60Hz, 2.8 A

120Vac, 1 ph, 2.5 A

Part F

 

 

  Gate 2 DG

120Vac, 1 ph, 50/60Hz, 5A

120Vac, 1 ph, 2 x 2.5A ( 2 motors)

Note: Those control unit shall be use only with products listed under M.C.251278 , CSA report 2367093 and 2520910. Refer to the openers certification report for details on controller and opener allow combination.

 

 

/mk