Customer Class File Number
Versa Products Company, Inc.
22 Spring Valley Rd
Paramus
New Jersey
United States
07652
3228-01
VALVES - For Hazardous Locations
045277_0_000

">

Series E4-xx98-xxXT-xxxx, E4-xx98-xxXU-xxxx and E4-xx98-xxXV-xxxx Solenoid Operated Valves; supply input rated 24 Vdc, 0.50 Watts or 24Vdc, 0.85 Watts or 24 Vdc, 1.8 Watts or 48 Vdc, 4.0 Watts or 120 Vac, 50/60 Hz, 1.8 W, or 120 Vac, 50/60 Hz, 4.0 Watts or 230 Vac, 50/60 Hz, 4.0 W; see Pressure Table for MWP (LV Coil (0.85W) – dc), see Pressure Table for MWP (LX Coil (1.8W) or Standard (4W)  – ac and dc); Tamb: –40 Deg. C to +90 Deg. C, Temperature Coded based on ambient range and construction options; Type 4X and 6P; IP66;

Series E4-xx98-xx-XDBT-xxxx Solenoid Operated Valves; supply input rated 24 Vdc, 0.50 Watts or 24Vdc, 0.85 Watts or 24 Vdc, 1.8 Watts or 48 Vdc, 4.0 Watts or 120 Vac, 50/60 Hz, 1.8 W, or 120 Vac, 50/60 Hz, 4.0 Watts or 230 Vac, 50/60 Hz, 4.0 W; see Pressure Table for MWP (LV Coil (0.85W) – dc), see Pressure Table for MWP (LX Coil (1.8W) or Standard (4W)  – ac and dc); Tamb: –40 Deg. C to +90 Deg. C, Temperature Coded based on ambient range and construction options; Type 4X and 6P; IP66;

Series E4-xx98-xxXS-xxxx, E4-xx98-xxXT-xxxx, E4-xx98-xxXU-xxxx and E4-xx98-xxXV-xxxx Solenoid Operated Valves; supply input rated 24 Vdc, 0.50 Watts or 24Vdc, 0.85 Watts or 24 Vdc, 1.8 Watts or 48 Vdc, 4.0 Watts or 120 Vac, 50/60 Hz, 1.8 W, or 120 Vac, 50/60 Hz, 4.0 Watts or 230 Vac, 50/60 Hz, 4.0 W; see Pressure Table for MWP (LV Coil (0.85W) – dc), see Pressure Table for MWP (LX Coil (1.8W) or Standard (4W)  – ac and dc); Tamb: –40 Deg. C to +90 Deg. C, Temperature Coded based on ambient range and construction options; Type 4X and 6P; IP66;

Series E4-xx98-xx-XDBS-xxxx and E4-xx98-xx-XDBT-xxxx Solenoid Operated Valves; supply input rated 24 Vdc, 0.50 Watts or 24Vdc, 0.85 Watts or 24 Vdc, 1.8 Watts or 48 Vdc, 4.0 Watts or 120 Vac, 50/60 Hz, 1.8 W, or 120 Vac, 50/60 Hz, 4.0 Watts or 230 Vac, 50/60 Hz, 4.0 W; see Pressure Table for MWP (LV Coil (0.85W) – dc), see Pressure Table for MWP (LX Coil (1.8W) or Standard (4W)  – ac and dc); Tamb: –40 Deg. C to +90 Deg. C, Temperature Coded based on ambient range and construction options; Type 4X and 6P; IP66;

Ratings and Coverage:  Gas Valves

  1. Valves with Type LZ Coil (0.50W) - dc, MWP of up to 120 psi depending on orifice size (Seal: FKM, BUNA, LT BUNA, EP, FVMQ
  2.  Valves with Type LV Coil (0.85W) – dc, see Pressure Table for MWP (Seal: FKM, BUNA, LT BUNA, EP, FVMQ)
  3. Valves with Type LV Coil (0.85W) – dc, MWP of up to 500 psi depending on orifice size and wattage; (Seal: FKM, BUNA, LT BUNA, FVMQ)
  4.  Valves with Type LX Coil (1.8W) or Standard (4W)  – ac and dc, see Pressure Table for MWP (Seal: FKM, BUNA, LT BUNA, EP, FVMQ)
  5. Valve body is made of stainless steel of different configuration ported for E4 operators having the same construction on the operator cavity.  The operators may be used with aluminum manifold or brass body having the same construction on the operator cavity.
  6. Valves with “-PLR” suffix (Seal LT Buna, Compound NB800-104) may be used at -55°C to +65°C ambient temperature range.alves with “-PLR” suffix (Seal LT Buna, Compound NB800-104) may be used at -55°C to +65°C ambient temperature range.

Ratings and Coverage:  Hydraulic Valves

  1.  Valves with Type LV Coil (0.85W) – dc, see Pressure Table for MWP.
  2.  Valves with Type LX Coil (1.8W) or Standard (4W) coil – ac or dc, see Pressure Table for MWP.
  3. Valves LV, LX and Standard (4W) are for use with #1 Oil at -15 Deg. C to +48 Deg. C ambient; or Hydraulic Oil (AWG 46) at -15 Deg. C to +95 Deg. C ambient.
  4. Valve body is made of stainless steel of different configuration ported for E4 operators having the same construction on the operator cavity.  The operators may be used with aluminum manifold having the same construction on the operator cavity.

Nomenclature

Model E4-ab98-cdXe-ffff where

a = Function; 2 (2-way), 3 (3-way), 7 (7-way diverter), 8 (8 –way Multi-purpose)
b = 1 (normally closed); 2 (normally open)
c = Bottom Seat Orifice; 0, 1, 2, 3, 4, 5, 6, 7, 8
d = Top Seat Orifice; 0, 1, 2, 3, 4, 5, 6
e = Conduit Thread, S, T, U, V
f = Voltage Code; A006 to A480, D005 to D300, E006 to E480

Model E4-ab98-cdXDBe-ffff where

a = Function; 2 (2-way), 3 (3-way), 7 (7-way diverter), 8 (8 –way Multi-purpose)
b = 1 (normally closed); 2 (normally open)
c = Bottom Seat Orifice; 0, 1, 2, 3, 4, 5, 6, 7, 8
d = Top Seat Orifice; 0, 1, 2, 3, 4, 5, 6
e = Conduit Thread, S, T,
f = Voltage Code; A006 to A480, D005 to D300, E006 to E480

Maximum Working Pressure Table

 

Solenoid Power

 

Seat

Std.

LX

LV

LZ

Size

(4.0 Watts)

(1.8 Watts)

(0.85 Watts)

(0.5 Watts)

Function

Code

Bottom

Top

AC/DC

AC/DC

DC

DC only

2-Way Normally Closed

21

2

0

500

400

250

120

3

0

400

300

150

60

4

0

200

200

80

N/A

6

0

100

100

N/A

N/A

8

0

60

50

N/A

N/A

 

 

 

 

 

 

 

 

2-Way Normally Open

22

0

2

400

300

175

N/A

0

3

200

150

100

N/A

0

4

125

100

N/A

N/A

0

6

75

50

N/A

N/A

 

 

 

 

 

 

 

 

3-Way Normally Closed

31

2

2

200

200

150

120

3

3

175

175

125

60

3

4

175

175

100

N/A

4

4

150

125

75

N/A

6

4

100

75

50

N/A

6

6

75

50

25

N/A

8

4

30

N/A

N/A

N/A

 

 

 

 

 

 

 

 

3-Way Normally Open

32

2

2

150

150

125

N/A

3

3

125

75

100

N/A

4

4

100

60

60

N/A

6

4

75

50

N/A

N/A

6

6

50

25

N/A

N/A

 

 

 

 

 

 

 

 

7-Way (Diverter)

72

2

2

300

250

110

N/A

3

3

250

200

100

N/A

4

4

175

150

80

N/A

6

4

80

120

N/A

N/A

 

 

 

 

 

 

 

 

8-Way (Multi-purpose)

82

2

2

150

150

125

N/A

3

3

100

75

100

N/A

4

4

75

60

40

N/A

6

4

50

30

N/A

N/A

6

6

30

20

N/A

N/A

Temperature codes and ambient ranges

The ambient temperature range and temperature code depend on the coil power and coil material. The tables

below show the various ambient temperature ranges for each coil material and power rating.

Ambient Ranges for X(TAB) models with F-class coils

Configuration

Temperature Code

Power

O-ring Material

T6

T5

T4

T3

1.80 W &

0.85 W &

0.50 W

EPDM

-40°C to +42°C

-40°C to +57°C

-40°C to +60°C

-40°C to +60°C

LT Buna

-40°C to +42°C

-40°C to +52°C

-40°C to +52°C

-40°C to +52°C

Buna

-20°C to +42°C

-20°C to +57°C

-20°C to +60°C

-20°C to +60°C

FKM

-20°C to +42°C

-20°C to +57°C

-20°C to +87°C

-20°C to +97°C

4 W

EPDM

-40°C to +31°C

-40°C to +46°C

-40°C to +60°C

-40°C to +60°C

LT Buna

-40°C to +31°C

-40°C to +46°C

-40°C to +52°C

-40°C to +52°C

Buna

-20°C to +31°C

-20°C to +46°C

-20°C to +60°C

-20°C to +60°C

FKM

-20°C to +31°C

-20°C to +46°C

-20°C to +60°C

-20°C to +60°C

 

 

Ambient Ranges for X(TAB) models with H-class coils

Configuration

Temperature Code

Power

O-ring Material

T6

T5

T4

T3

1.80 W &

0.85 W &

0.50 W

EPDM

-55°C to +42°C

-55°C to +57°C

-55°C to +60°C

-55°C to +60°C

LT Buna

-40°C to +42°C

-40°C to +52°C

-40°C to +52°C

-40°C to +52°C

Buna

-20°C to +42°C

-20°C to +57°C

-20°C to +60°C

-20°C to +60°C

FKM

-20°C to +42°C

-20°C to +57°C

-20°C to +87°C

-20°C to +105°C

4 W

EPDM

-55°C to +31°C

-55°C to +46°C

-55°C to +60°C

-55°C to +60°C

LT Buna

-40°C to +31°C

-40°C to +46°C

-40°C to +52°C

-40°C to +52°C

Buna

-20°C to +31°C

-20°C to +46°C

-20°C to +60°C

-20°C to +60°C

FKM

-20°C to +31°C

-20°C to +46°C

-20°C to +76°C

-20°C to +105°C

 

Ambient Ranges for XDB(TAB) models with F-class coils

Configuration

Temperature Code

Power

O-ring Material

T6

T5

T4

T3

1.80 W &

0.85 W &

0.50 W

EPDM

-40°C to +55°C

-40°C to +70°C

-40°C to +80°C

-40°C to +90°C

LT Buna

-40°C to +55°C

-40°C to +60°C

-40°C to +60°C

-40°C to +60°C

Buna

-20°C to +55°C

-20°C to +70°C

-20°C to +80°C

-20°C to +90°C

FKM

-20°C to +55°C

-20°C to +70°C

-20°C to +90°C

-20°C to +90°C

4 W

EPDM

-40°C to +42°C

-40°C to +57°C

-40°C to +60°C

-40°C to +60°C

LT Buna

-40°C to +42°C

-40°C to +46°C

-40°C to +52°C

-40°C to +52°C

Buna

-20°C to +42°C

-20°C to +56°C

-20°C to +56°C

-20°C to +56°C

FKM

-20°C to +42°C

-20°C to +57°C

-20°C to +80°C

-20°C to +80°C

 

Ambient Ranges for XDB(TAB) models with H-class coils

Configuration

Temperature Code

Power

O-ring Material

T6

T5

T4

T3

1.80 W &

0.85 W &

0.50 W

EPDM

-55°C to +55°C

-55°C to +70°C

-55°C to +80°C

-55°C to +90°C

LT Buna

-40°C to +55°C

-40°C to +60°C

-40°C to +60°C

-40°C to +60°C

Buna

-20°C to +55°C

-20°C to +70°C

-20°C to +80°C

-20°C to +90°C

FKM

-20°C to +55°C

-20°C to +70°C

-20°C to +90°C

-20°C to +90°C

4 W

EPDM

-55°C to +42°C

-55°C to +57°C

-55°C to +60°C

-55°C to +60°C

LT Buna

-40°C to +42°C

-40°C to +56°C

-40°C to +56°C

-40°C to +56°C

Buna

-20°C to +42°C

-20°C to +57°C

-20°C to +60°C

-20°C to +60°C

FKM

-20°C to +42°C

-20°C to +57°C

-20°C to +87°C

-20°C to +90°C

Solenoid Operated General Purpose Valves, Series DSM – abbc – 316 – XDDd – eeee, where a = 2 or 3, bb = 30 or 36, c = 2, d = S or T, eeee = voltage codes, rated 12 or 24 or 48 or 110 or 125 VDC, 2.6 Watts or 28VDC, 2.9W  or 110 or 120 or 220 or 240 VAC, 50 or 60 Hz, 3.1 Watt; 175 psi MWP; Tamb: –52 ºC to +90ºC, Coil Insulation H These valves are 2-way normally open, 3-way normally open, 3-way diverter and 3-way selector, intended to control the flow of gas and hydraulic fluids as indicated below.

Note: When “LLP” suffix is added to valve model number, the power rating of valve is 1.0W and is only applicable to 12V or 24V DC valve model. Ambient temperature of the valve is -40°C to +90°C

Coil Insulation Classification:  180(H) (PPS Material, Ryton)

Maximum Operating Pressure:  175 psi

Note: a) The DSM Series valves are not intended for used as safety shut-off valves for fuel gas and have not been evaluated to the applicable requirements

              of ANSI Z21.21/CSA 6.5

          b) They are installed per Installation Instructions INS-XDD-1.

Nomenclature:

Model DSM - abbc - 316 – XDDd - eeee where

a = Function; 2 (2-way), 3 (3-way, Multi-purpose)

b = Body ports, 30 (1/4” NPT), 31 (Manifold Mount), 36 (G1/4)

c = 1 (normally closed); 2 (normally open)

d = Conduit Thread, S, T

e = Voltage Code:

A120 = 120V, 60Hz;

A240 = 240V, 60Hz;

D012 = 12VDC;

D024 = 24VDC;

D028 = 28VDC;

D048 = 48VDC;

D110 = 110VDC;

D125 = 125VDC;

E110 = 110V, 50Hz;

E220 = 220V, 50Hz

Other Options:

- M = Manual Override (momentary)

- M5R = Manual Override (maintained)

- NA = (Nace Spring)

- 356BN = Latch Option without button

- 356B = Latch Option with button

- 303 = MOV Option

- 303D = Free Wheeling Diode Option

- 303T = Transient Voltage Suppressor

- 44 = Low Temperature Buna Seals

- T40 = Multipurpose Fluorosilicone

- LLP = Low power option to add the Hit-and-Hold Circuit Board to the valve

 

/tm