Customer Class File Number
Chromalox Inc.
103 Gamma Dr Ext
Pittsburgh
Pennsylvania
United States
15238
2871-02
HEATERS - Miscellaneous
040859_0_000

  • Cartridge elements Types CIR, CRP and CSIR, 300W/sq in max, 1/4 in to 5/8 in od, 240V and less, 1/2 in and 3/4 in od, 480V and less, 140W/sq in max.

Notes:

  1. Suffix numbers are added to the type designation denoting diameter and length.
  2. Suffix "S" is added to the type designation to denote swaged-on alloy sleeve.
  • Screw plug immersion heaters 120 or 240V, Types RI, 1000W max, 36W/sq-in max; RI0, 600W max, 22W/sq-in max; RINO, 600W max, 25W/sq-in max; RIN, 1000W max; 40W/sq-in max; RIS, 750W max, 35W/sq in max; RIH, 1000W max, 35W/sq in max.

Note: Suffix numbers are added to the type designation denoting diameter and wattage.

  • Ring elements, single and three-heat, 240V max, Types A, E, L, S, HSW, 2400W max, 26W/sq-in max, Type HSP, 450W max.

Note: Prefix R may be added to Types A, E, L, S and HSW to denote rivets or threaded studs for mounting means. Note: The above heaters are Certified only for use in equipment where the suitability of the combination is determined by the Canadian Standards Association.

  • Strip element, 288V max, Types S, PT, SNH, WS, 1500W max; SE, TH, 4500W max; SN, 600W max; NH, 800W max, 300W max; ST, 1000W max; Type OT, 1500W max.
  • Finstrip elements, 288V max, Types SEF, PTF, SSEF, 4150W max, 300V max, Type OTF, 4150W max.
  • Koilfin elements, Type KSEF, 240V max, 5000W max.
  • Defrost heaters, tubular, metal-sheathed, 240V and less, Series 871000 and 872500, for dry location, 2400W and less, 4.71W per linear in and less; Series 87, for wet location, 4000W and less, 350W per linear ft and less (incoloy); 2400W and less, 100W per linear ft and less (aluminum); 2000W and less, 80W per linear ft and less (copper).
  • Immersion heaters, tubular, metal-sheathed, 600V and less, Series 427-, 12kW and less, 212W/sq-in. - Compressor crankcase heater, Series 322-87, rated 240V ac max, 65W max, 30W per sq-in max.
  • Oven elements, tubular metal sheathed type, Series 029-87, 202-87, 415-87,416-87, 417-87, 418-87, 250V and less, max watts density 65W/sq-in for 0.260 in dia sheath, 60W/sq-in for 0.315 in dia sheath, 50W/sq-in for 0.430 in dia sheath.
  • Immersion heater Series 436-302190 followed by three digits, 480V max,75W/in sq max.
  • Flanged tubular elements, Series 78F, 600V and less, 50A max with max watt density of 180W per sq-in. Heaters, metal-sheathed, tubular, Series 67G, 208-406V, 3900-5300W.
  • Electric heater elements, immersion type, Model Series B, D, F, G, R, T, for use up to 300V and up to 30A.
  • Electric heater elements, immersion type, Cat No 85P-1267, 115V, 1400W max; Cat No 85P-1271-1, 115V, 750W; Cat No 85P-1271-2, 240V, 750W.
  • Range surface elements, 240V max, 60Hz, Models P4, AS4, S4, 70A, 660W max; P6, AS6, S6, 70B, 1650W max; P8, AS8, S8, 70C, 2600W max.
  • Bake, boil and griddle heater elements, Series 66, T-T, followed by suffix letters and/or numbers, 600V ac max, 60W/sq-in max.

Notes:

  1. The above heaters are Certified only for use in equipment where the acceptability of the combination is determined by the Canadian Standards Association.
  2. The above "Watts per linear in or ft" respectively refer to the heated portion of the element.
  3. The defrost heater series designations have three prefix numbers (manufacturers reference to drawing number system).
  4. Series "87" has suffix numbers (manufacturers reference to drawing number system).
  5. The immersion heater element catalogue number consists of the series number 157-87 followed by 7 suffix digits, 427-, 157- followed by 9 suffix digits.
  6. The oven element catalogue number consists of the 5 digit series designation followed by 7 suffix digits.
  7. On oven elements, the required marking is die stamped on the sheath or supporting brackets.
  8. Series 319, 393, and 118 heaters are followed by 9 digits.
  9. The model designation of the crankcase heater may include additional seven random digits suffix.
  10. Model Series B, D, F, G, R, T, may be followed by additional suffix numbers and letters.
  11. Series 78F elements may have suffix numbers to indicate electrical rating and customer part number.
  12. The Certification of range surface elements Models P4, S4, AS4, 70A, P6, AS6, S6, 70B, P8, AS8, S8 and 70C includes their use in combination with Certified Molex Corp. range receptacle block Part No P-50-16-0281. The final acceptability of the heater element-terminal block combination in a product is to be determined by the Canadian Standards Association.
  • Screw plug immersion heaters, Series EMT, MT, TM*, TMW, TMW-1, TMW-2, DWH-MR, DWH, ARCEMT, ARCMT, AREMT, ARMT, ARTM, ARTMW, 600V and less (except where 0.246 in dia heaters are used the limit is 250V and less) 212W/sq in max.
  • Flange type immersion heaters, Series TTSF, HI, WI, TTUH, TM*, 600V and less (except where 0.246 in dia heaters are used, the limit is 250V and less), 212W/sq in max. * May be either a screw plug or flange type heater.
  • Flanged immersion heaters, Series 436-302354 or 436-303871, 480V max, 120W per sq in max.- Flanged immerson heaters, Series TMP, TMIP, TMIIP, TMISP, TMMP, TMSP, TMSSP, TMSSSP and TMTP, followed by suffix letters and numbers, rated 600V and less, with watt density limit 90 per sq. in.

Notes:

  1. The screw plug immersion heaters, Series EMT and MT, followed by one or two digit to identify the unit series. Series EMT, MT and TM, followed by a max of four digits to identify the rating, may be provided with the suffixes I, II, IS, M,O, OIS, OS, OSS, S, SS, T, W, WI, WS, WSS, E4, C30, C31, C32, C33, C36, C37, V, W or XX and may include Prefix AR or ARC. Series may include model Suffix A, 3 or 3A. Series EMT and MT with prefix AR may include suffixes T1, T2, T3, T4, T5 or T8, Series EMT and MT with prefix ARC may include suffixes T1, T2 or T3.   Series TM with prefix AR may include suffixes TL or TH.
  2. The screw plug immersion heaters, Series TMW-1 and TMW-2, followed by a max of four digits to identify rating, may be provided with the suffixes I, S, SS, V, W or XX.
  3. The flanged type immersion heaters, Series TM, may be provided with the suffixes I, II, IS, M, O, S, SS, SSS, T, B or F, followed by 2, 3, 4, 6, 9, 12, 15, 18, 24, 27A, 27, 36A, 36, 45, 54, 60, 72 or 90 to identify the element quantity followed by a max of three digits to identify the rating, may be provided with suffixes 5, 15, 25, 3, 4, 6, 9, 15, 25, F1, H, L, M, R1, E4, T1, T2, T3, C30, C31, C32, C33, C36, C37, A, S, V, W or XX.
  4. The screw plug immersion heaters, Series DWH and DWH-MR followed by a max of 2 digits to identify the rating, may be provided with suffixes I or S. Series DWH-MR may be provided with suffixes PS.
  5. The flange type immersion heaters, Series TTUH, followed by a max of four digits to identify the rating, provided with suffixes CO when thermostat is included, may be provided with suffix A.
  • Seamless strip heaters, Series NS, NSA, NSL, SSNH, NNSHM, SSE, SSEB, 600V and less 212W/sq in max.

Note: The above heaters are Certified only for use in equipment where the acceptability of the combination is determined by the Canadian Standards Association.

  • Cartridge heaters, Series C-2, C-3, C-4, C-5, C-6, C-7 and C-8, 240V max, 50W/sq in max; C-08, 480V max, 42W/sq in max.

Notes:

  1. Suffix numbers may be added to all cartridge heater series for customer identification not affecting CSA Certification.
  2. Suffixes J1, J2, J3, K1, K2 or K3 may be added to cartridge heater Series CIR (3/8, 3/4 dia) C-2, C-3, C-4 and C-5 to denote the addition of Type J or Type K thermocouple and its location.
  3. A Suffix S may be added to all cartridge heater series to denote the addition of a swaged-on stainless steel sleeve.
  4. Suffixes 2C to 12C may be added to denote the addition of fittings.
  • Double end cartridge heaters, Type CDE, 240V max, 23W/sq in max.
  • Space heater, Edison screw base, Type SCB, 120V max, 15W/sq in max.
  • Single end immersion heater, metal sheathed, Series 436-620065 followed by three digits, 240V max, 75W/in squared max.

Note: The above heaters are Certified only for use in equipment where the suitability of the combination is determined by the Canadian Standards Association.

  • Cartridge immersion heater with screw plug mounting and built in thermostat, Model RIST 4XXX, rated 240 V ac, 60 Hz, 1000 W max, 150 W/sq-in, 5/8 in OD.

Notes:

  1. The above heaters are certified only for use in equipment where the acceptability of the combination is determined by the Canadian Standards Association.
  2. Suffix XXX indicates wattage rating.
  • Corrosion resistant immersion heaters, Models TPR and TPF, 480V max, 60Hz, 22W per sq in max.

Notes:

  1. The model number is followed by two suffix numbers denoting watts, followed by one or two suffix numbers denoting volts.
  2. The above heaters are Certified only for use in equipment where the suitability of the combination is determined by the Canadian Standards Association or Local Inspection Authorities.
  • General purpose tubular metal sheathed type, Series 319 (straight tubular heaters) 393 (bent tubular heaters) 600V and less, max watt density 65W/sq-in for 0.246 in and 0.260 in dia sheathed, 60W/sq-in for 0.315 in dia and 0.375 in dia, 50W/sq-in for 0.420, 0.430, 0.475 and 1/2 in dia.
  • Finned metal sheathed tubular heaters, Series 118 (followed by 9 digits) 600V and less 13,300W and less, max 70W/sq-in*. The watt densities are limited in application to max allowable temperature for sheath material.
  • Immersion heaters tubular metal-sheathed, Series 157, 157-87, 600V and less, 6000W and less, max 160W/sq-in.

Notes:

  1. The above elements are Certified only for use in equipment where the acceptability of the combination is determined by the Canadian Standards Association.
  2. The element (straight, bent and finned) catalogue number consists of the 3 digit series designation followed by 9 suffix digits.
  3. On elements, the required marking is die-stamped on the sheath or supporting bracket.
  4. The above "Watts per linear in or ft" respectively refer to the heated portion of the element.
  5. The immersion heater element catalogue number consists of the Series No 157-87 followed by 7 suffix digits and 157 followed by 9 suffix digits.
  6. *The Series 118 heater elements are rated 70W/sq-in max, except elements provided with stainless steel 304 sheath are rated 80W/sq-in max.
  • Air circulation heaters, Models GCHIS-C, GCHS-C, GCHSS-C, 480V max, 6000W max, 75W/in{ max, GCHIT-C, GCHISTI-C, GCHSTI-C, GCHSSTI-C, 240V max, 1200W max, 20W/in{ max.
  • Circulation heater, Models NWH, NWHI, NWHIS, HWHS, HWHSS followed by suffix numbers 151, 201, 251 or 301, 120V ac, 2.5kW max, 208 or 240V, 3.0kW max; NWH, NWHI, NWHII, NWHIS, NWHM, NWHO, NWHOIS, NWHOS, NWHOSS, NWHS, NWHSS, NWHSSS, NWHT followed by suffixes 2A, 3, 6, 9, 12, 15, 18, 24, 27, 36A, 36, 45, 54, 60, 72 or 90, 120, 208, 240, 380, 415, 440, 460, 480, 550, 575 or 600V ac, 500kW max; NWH-2, NWHI-2, NWHO-2, NWHS-2, 120, 208, 240, 380, 415, 440, 460 or 480V ac, 5.0kW max; NWHMT-3, NWHMTI-3, NWHIMTII-3, NWHISMTI-3, NWHMMTM-3, NWHMTO-3, NWHMTOIS-3, NWHMTOS-3, NWHMTOSS-3, NWHMTS-3, NWHSMTS-3, NWHSSMTSS-3, NWHTMTT-3, 120, 208, 240, 380, 415, 440, 460, 480, 550, 575 or 600V ac, 25kW max.- Circulating heater, Model NWHOF-904003C36AAHVXX rated 575V ac, 400kW, 3-3 ph.
  • Circulation Heaters, Models GCHI, GCHIS, GCHS, GCHSS, may be followed by suffix letter R and/or B, followed by suffixes to denote rating, construction and optional features, rated 600V ac max, 400kW max, 25W/in sq. max.
  • Circulation Heaters, Models GCHMTI, GCHMTIS, GCHMTS, GCHMTSS, may be followed by letter R, followed by suffixes to denote rating, construction and optional features, rated 600V ac max, 9kW max, 25W/in sq. max.
  • Circulation Heaters, Model GCHAI, followed by suffixes to denote rating and construction, rated 480V ac max, 1.5kW max, 20W/in sq. max.
  • Flanged immersion heater, Model TMOB904003E4036AAVXX rated 575V ac, 400kW, 3-3 ph.
  • Immersion type heaters for heating water base or oil base liquids, Model Series TL and KTL followed by up to 13 suffix numbers and letters; 600V ac max, 39kW/50W/in max.

Notes:

  1. Suffixes may be added to the model designations to denote rating and construction.
  2. Heaters are Certified only for use in equipment where the Acceptability of the combination is determined by the Canadian Standards Association or local inspection authorities.
  • Component heater assemblies, Model Series ADH, 600V max, 270kW max, 60Hz, 1 or 3 ph; Model Series ADHT, 600V max, 300kW max, 60Hz, 1 or 3 ph; Model Series CDH, 600V max, 100kW max, 60Hz, 1 or 3 ph; Model Series TDH, 600V max, 60kW max, 60Hz, 1 or 3 ph. All model numbers with or without suffix letters and numbers.

Note: Heaters are Certified only for use in equipment where the acceptability of the combination is determined by the Canadian Standards Association or local inspection authorities.

  • DRA-XX-YY - rated 208V-600V, 7.5KW to 30.0 KW, 60Hz, Cord or Permanently-connected.

Note:  XX = Rep. Wattage, YY = Rep. Voltage, Phze, Hz.

/jt