Cookies on CSA Group

We use cookies to enhance your browsing experience, serve personalized content, and analyze our traffic. Cookies are small files of information stored on your device that help us remember your preferences and improve your experience. By clicking ‘Accept All’, you consent to our use of cookies. You are able to reject all non-essential cookies or manage your preferences by . To learn more about our Online Digital and Cookie Notice, click here.

logo close
Cookie Preference Center

Please manage your cookie choices by switching the consent toggles on or off under the Purposes below.

You may change your preference at any time as described in our Cookie Policy

  • Cookie Settings
  • List of Cookies
close
    Skip to content
    CSA Group logo, links to home CSA Store Main Page
    • Cart ()
    • Login / Register
    • English
      • French
    • USD
      • CAD
    • Language
      • English
      • French
    • Currency
      • CAD
      • USD
    • CSA OnDemand™
    CSA Group logo, links to home CSA Store Main Page
    • Cart ()
    • Login / Register
    • English
      • French
    • USD
      • CAD
      • CSA OnDemand™
    10 results found

    Products

    Landing Pages

    • Browse Catalogue
      • Browse By Subject Area
        • Electrical
        • Fuels & Transportation
        • Petroleum & Natural Gas
        • Environment & Natural Resources
        • Construction & Infrastructure
        • Mechanical & Industrial Equipment
        • Nuclear
        • Health Care and Well-being
        • Worker & Public Safety
        • Management Systems
        • Agriculture and Agrifood
      • Browse By Publisher
        • ASME
        • ASTM
        • CSA Group
        • ESA
        • IEC
        • ISO
        • NRC
        • ORNAC
        • TSSA
      • Browse By ICS Code
      • CSA Learning
      • Subscription Collection
    • Services
    • Home
    • chevron_right
    • ORNAC 17th edition - 2025 & MDR (CSA Z314:23) Collection
    Collection - Subscribe

    ORNAC 17th edition - 2025 & MDR (CSA Z314:23) Collection

    Guidelines for Perioperative Practice in Canada

    SKU: 2704999 2 Documents Included

    Product Details

    • Preface/Scope
    • Items Included

    ORNAC 17th edition - 2025


    ORNAC’s Guidelines for Perioperative Practice in Canada serve as a reference and guide for perioperative nurses, health care facilities caring for surgical patients, professional associations, and other organizations involved in surgical services. These guidelines represent recommended practices based on the best-available evidence to help perioperative nurses deliver optimal patient care in the perioperative setting. Considering the diverse practice areas and roles across the country, the ORNAC Guidelines are an important tool in the clinical decision-making process.


    -----------------------------------------------------------------------------------------------------------------------------------------------


    CSA Z314:23, Canadian medical device reprocessing


    Preface


    This is the second edition of CSA Z314, Canadian medical device reprocessing in all health care settings. It supersedes the previous edition published in 2018 under the title Canadian medical device reprocessing.


    This Standard addresses the safe and effective reprocessing of medical devices and supplies.


    Changes to this edition include the following:


    a) Revised the Scope (Clause 1) to extend coverage of heath care settings to include professional offices, independent doctors’ offices, community health care centres, private practices, and additional health care settings as applicable, as well as exclusion of sterilization by injecting ethylene oxide (EO) or mixtures containing EO directly into packages or a flexible chamber.


    b) Revised the general requirements (Clause 4) for minimum level of reprocessing for semi-critical medical devices and handling of reusable medical devices, including risk assessment.


    c) Updated requirements for quality management systems (Clause 5), including key performance indicators, water quality, as well as leadership, planning, provision of resources, and operation improvements.


    d) Updated requirements for personnel (Clause 6) covering competency training and continuing education, including occupational health and safety and infection prevention and control training.


    e) Updated requirements for manufacturer’s instructions for use (Clause 7), covering new technologies, evaluation, and purchase of reusable medical devices, as well as reprocessing of sterile barrier systems and consumables.


    f) New and expanded requirements for evaluation and purchase of reusable medical devices (Clause 8).


    g) New and expanded requirements for loaned reusable medical devices (Clause 9), including modifications and alterations, licensing requirements, documentation and records, as well as safe handling and transportation.


    h) Updated requirements for work areas and design (Clause 10), covering hand hygiene facilities, decontamination sinks, eyewash stations and deluge showers, and clean and sterile storage area, including shelving and environmental controls.


    i) New and expanded requirements for decontamination of reusable medical devices (Clause 11), covering handling (point of use cleaning, sorting, sharps, and fluid management), retrieval and transport to the decontamination area, sorting and disassembly, preparation, cleaning, rinsing and drying, decontamination after manual cleaning, and disinfection of semi-critical medical devices, including requirements for liquid chemical disinfection and respiratory devices.


    j) New and expanded requirements for flexible endoscopes (Clause 12), including point of use cleaning, reprocessing, transportation, leak testing, cleaning and rinsing, disinfection of sinks manual high-level disinfection, automated repossessing, storage sterilization, as well as special requirements for endoscopic accessory devices, damaged endoscopes, etc.


    k) New and expanded requirements for ultrasound transducer probes (Clause 13), including reprocessing area, traceability, point of use cleaning, transportation, electric leak testing manual cleaning, rinsing, inspection including requirements for ultrasound probe sterilization, automated reprocess drying and storage preventative maintenance, and record keeping


    l) New and expanded requirements for preparation of medical devices for reprocessing (Clause 14), covering modifications and alterations, requirements for medical devices with lumens, instrument care and handling, verification of cleanliness and functionality, and lubrication, including additional requirements for basin sets, textile packs and trays, and low-temperature sterilization methods.


    m) New and expanded requirements for selection and use of sterile barrier systems (Clause 15), covering evaluation, purchase and inspection, packaging systems, qualifications, product design, assembly, labelling, pouches, wrappers, and rigid sterilization containers systems.


    n) New and expanded requirements for sterilization methods (Clause 16), covering preferred methods, critical and semi-critical medical devices, sterilizer loading, operation and unloading, liquid chemical, steam sterilizers and ethylene oxide aeration, storage of chemical sterilant and supplies, sterility assurance, routine monitoring, immediate-use steam sterilization, and table-top sterilizers.


    o) New and expanded requirements for storage transportation and distribution of single use and reusable medical devices (Clause 17), including general requirements (SOP, storage, shipping containers, cardboard boxes, and window and door access storage), physical and functional storage requirements, traffic and environmental conditions, equipment, water controls, Tier 3 storage area, case carts, and emergencies.


    p) New and expanded requirements for table-top sterilizers (Clause 18), including submicron water filter maintenance, repair or refurbishing of reusable medical devices, and utilities (steam generation, feed water, and piping networks).


    q) New and expanded requirements for selection of gowns and drapes (Clause 19), covering evaluation and purchase (barrier classification flammability and biocompatibility), selection (including surgical gowns, isolation gowns, and surgical drapes), and containment and handling of soiled gowns at the point of use.


    r) New clause and expanded requirements for environmental cleaning (Clause 20), covering general requirements, SOPs, dress code, OHS, personnel, cleaning (including cleaning of MDRA, equipment), transportation vehicles and cart covers, and cleaning of laundry areas.


    s) New and expanded requirements for laundering, preparation of reusable gowns, drapes, and wrappers (Clause 21), covering SOPs, purchasing decisions, personnel, work areas and equipment, water quality and temperature, prevention of stains and damage to reusable textiles, maintenance, handling, transportation receiving, storage of reusable soiled and cleaned textiles, and laundering.


    t) Annexes have been updated.


    CSA acknowledges that the development of this Standard was made possible, in part, by the financial support of the governments of Alberta, British Columbia, Manitoba, New Brunswick, Newfoundland and Labrador, Northwest Territories, Nova Scotia, Nunavut, Ontario, Prince Edward Island, Québec, Saskatchewan, and Yukon, as administered by the Canadian Agency for Drugs and Technologies in Health (CADTH).


    This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.


    This Standard was prepared by the Technical Committee on Medical Device Reprocessing, under the jurisdiction of the Strategic Steering Committee on Health and Well-Being and has been formally approved by the Technical Committee.


    This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group.


    Scope


    1.1 Standard addresses


    This Standard is intended to address the safe, effective, and reliable reprocessing of reusable medical devices at each phase of the reprocessing workflow, including


    a) establishing a QMS for the MDRA, including


    i) key performance indicators;


    ii) policies and procedures;


    iii) documentation;


    iv) roles and responsibilities;


    v) management review;


    vi) planning, resources, and operations;


    vii) environmental conditions and infrastructure; and


    viii) recalls and alerts;


    b) personnel requirements, including


    i) qualifications;


    ii) occupational health and safety; and


    iii) infection prevention and control;


    c) manufacturer’s instructions for use (MIFUs);


    d) evaluation and purchase of reprocessing equipment and reusable medical devices;


    e) loaned, reusable medical devices;


    f) work areas and design;


    g) environmental conditions;


    h) utilities (e.g., power supply, water, and steam quality);


    i) the reprocessing workflow, including


    i) decontamination;


    ii) preparation of medical devices for reprocessing;


    iii) sterile barrier systems;


    iv) sterilization methods;


    v) storage, transportation, and distribution; and


    vi) equipment maintenance and quality assurance;


    j) sterile storage;


    k) selection and use of gowns and drapes; and


    l) laundering, maintenance, and preparation of reusable gowns, drapes, and wrappers.


    1.2 Health care settings standard applies to


    This Standard applies to health care settings or providers where medical device reprocessing (MDR) occurs including, but not limited to,


    a) all acute care hospitals;


    b) trauma centres;


    c) emergency care facilities;


    d) medical clinics with or without overnight stay or observation;


    e) endoscopy centres;


    f) laser eye clinics;


    g) outpatient surgical services;


    h) cosmetic surgical offices;


    i) dental general and surgical facilities;


    j) other office surgical facilities;


    k) general physician offices (with and without treatment spaces);


    l) stand-alone laboratory facilities;


    m) diagnostic imaging centres;


    n) nursing homes;


    o) long-term care facilities;


    p) assisted-living facilities;


    q) mental health facilities;


    r) forensic facilities;


    s) rehabilitation facilities;


    t) health care professional offices (e.g., occupational therapy, physiotherapy, ostomy);


    u) chronic care facilities;


    v) group homes;


    w) hospice care facilities;


    x) stand-alone dialysis clinics;


    y) ambulatory clinics;


    z) walk-in health clinics and independent doctor’s offices;


    aa) pediatric clinics;


    bb) public health clinics;


    cc) adult daycare centres;


    dd) third-party reprocessors;


    ee) educational settings;


    ff) community health centres;


    gg) private practices for health care professionals (e.g., foot care or any home based reprocessing); and


    hh) additional health care settings as applicable.


    1.3 Standard does not apply


    This Standard does not address


    a) reprocessing of single-use/disposable medical devices;


    Notes:


    1) Information concerning safety, technology, cost/benefit, and legal issues involving the reuse of such medical devices is found in such publications as CADTH (2015).


    2) See also Health Canada Update: Notice to Stakeholders — Health Canada’s Regulatory Approach to Commercial Reprocessing of Medical Devices Originally Labelled for Single Use, available at


    b) sterilization by injecting ethylene oxide (EO) or mixtures containing EO directly into packages or a flexible chamber; and


    c) medical devices that have been used with patients (clients) who are known or suspected to have Creutzfeldt–Jakob Disease (CJD) or prion-related diseases.


    Note: See PHAC’s Infection Control Guidelines: Classic Creutzfeldt — Jakob disease in Canada. Quick Reference Guide.


    1.4 Terminology


    In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.


    Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.


    Notes to tables and figures are considered part of the table or figure and may be written as requirements.


    Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

    Download a list of included items
    items 1 - 1 of 1 result(s)
    View 20 | View 100

    ORNAC 17th edition - 2025

    Guidelines for Perioperative Practice in Canada

    Active
    EnglishFrench

    CSA Z314:23

    Canadian medical device reprocessing in all health care settings

    Active
    EnglishFrench

    Subscribe

    Annual subscription keeps you up-to-date with the latest editions of standards and includes all supported languages and archive versions. 

    * Price is for up to 10 users. Select the number of users required on the cart page. Subscription must include a minimum of 10 standards or a collection to proceed to checkout.

    Includes annual access to:

           • Newest and previous editions in PDF format 
           • Revisions, updates and amendments 
           • All supported languages 

    Learn More

    PDF

    • help FAQs
    • call Contact Us
    • mailEmail Product

    GST REG No R119441681
    QST REG No R1006017360

    Compare Formats

    Determine the subscription format that is right for you.

    Select the subscription format that is right for you. Table with 13 rows and 3 columns, identifies features available and not available for the two different subscription formats - CSA Advantage TM and CSA OnDemand TM
    Features CSA AdvantageTM CSA OnDemandTM
    Offline access CSA AdvantageTM. feature available. Offline access CSA OnDemandTM. feature available. Offline access
    Full-text search CSA AdvantageTM. feature available. Full-text search CSA OnDemandTM. feature available. Full-text search
    Create highlights and personal notes CSA AdvantageTM. feature available. Create highlights and personal notes CSA OnDemandTM. feature available. Create highlights and personal notes
    Newest editions added automatically CSA AdvantageTM. feature available. Newest editions added automatically CSA OnDemandTM. feature available. Newest editions added automatically
    Includes all supported languages and archive versions CSA AdvantageTM. feature not available. Includes all supported languages and archive versions CSA OnDemandTM. feature available. Includes all supported languages and archive versions
    My Files - create customized files by adding multiple clauses, tables or figures from the standard into your own personal File for quick reference CSA AdvantageTM. feature available. My Files - create customized files by adding multiple clauses, tables or figures from the standard into your own personal File for quick reference CSA OnDemandTM. feature not available. My Files - create customized files by adding multiple clauses, tables or figures from the standard into your own personal File for quick reference
    Toggle between your files and the full standard to maintain context CSA AdvantageTM. feature available. Toggle between your files and the full standard to maintain context CSA OnDemandTM. feature not available. Toggle between your files and the full standard to maintain context
    Instantly preview cross referenced material within the book CSA AdvantageTM. feature available. Instantly preview cross referenced material within the book CSA OnDemandTM. feature not available. Instantly preview cross referenced material within the book
    Export personal notes to Excel CSA AdvantageTM. feature available. Export personal notes to Excel CSA OnDemandTM. feature not available. Export personal notes to Excel
    Transfer notes and highlights when updates are available CSA AdvantageTM. feature available. Transfer notes and highlights when updates are available CSA OnDemandTM. feature not available. Transfer notes and highlights when updates are available
    Adobe Reader PDF and browser compatible for iOS and Android CSA AdvantageTM. feature not available. Adobe Reader PDF and browser compatible for iOS and Android CSA OnDemandTM. feature available. Adobe Reader PDF and browser compatible for iOS and Android
    Web, Android, iOS Compatible CSA AdvantageTM. feature available. Web, Android, iOS Compatible CSA OnDemandTM. feature not available. Web, Android, iOS Compatible
    • About CSA Store
    • Subscription
    • Services
    • Catalogue
    • Return Policy
    • Fulfillment Details
    • eBook Support
    • Product Updates
    • CSA Group
    • CSA Communities
    • CSA Update Service
    • FAQ
    • Contact Us
    Get CSA Newsletter

    Follow Us On Social Media

    • General Terms and Conditions
    • Privacy Policy
    • Accessibility

    © 2025 Canadian Standards Association. All rights reserved

    Free Login/Registration Required

    View Access for this document is only available for viewers in Canada.

    A free user account is required to view this document.

    Login or Register