Class Number Description
7030-01
PIPE AND PIPE FITTINGS - Floor Drains, Trench Drains, Sanitary Floor Sinks and Cleanouts

 

COVERAGE:

 

Floor drains, adjustable floor drains, and area drains that are used inside of, or adjacent to, building structures.

 

Sanitary floor sinks, that is designed and installed for the purpose of draining indirect waste to

a sanitary drainage system.

 

Cleanouts, including floor and wall types, used in concealed piping in and adjacent to residential, commercial, industrial, institutional, and other buildings open to the public.

 

Trench drains, utility channels, and grate systems that are used inside of, or adjacent to, building structures that are typically non- residential.

 

REQUIREMENTS:

ASME A112.36.2/CSA B79.2

Cleanouts

ASME A112.6.3/CSA B79.3

Floor drains

ASME A112.6.7/CSA B79.7

Sanitary floor sinks

ASME A112.6.8/CSA B79.8

Trench drains

 

MARKING:

All markings required by CSA must be permanent, legible, and visible after the installation of the product. The markings are to be located as required in the standard. The contents consist of:

  • CSA Mark;
  • Submittor's identification;
  • Additional markings may be required by the applicable Standard(s) for specific models or usages.

 

Acceptable means of applying permanent markings shall include etching, mechanical stamping, stamping with a permanent (non-water-soluble) ink, and moulding in.

 

Adhesive labels that comply with CSA C22.2 No. 0.15 or UL 969 shall also be considered permanent when placed on a surface that is not normally submerged in water. The exposure conditions specified in Clause 7.1 of UL 969 shall apply.

 

The manufacturer is responsible for ensuring that their products meet any additional (non-certification related) applicable marking requirements.

 

Products shall be installed in accordance with the Local Code of the Authority Having Jurisdiction.