Certification Record | CSA Group.
Customer | Class | File Number |
---|---|---|
Tekima S.r.l.
Via Carlo Signaroli, 3
Borgosatollo
Brescia
Italy
25010
|
5851-01
WIRES - Appliance
|
265572
|
TO THE REQUIREMENTS OF CSA STANDARD C22.2 NO 210-11:
AWM Class |
AWM Group |
Temp Rating (Deg C) |
Voltage Rating (V) |
Jacket Type/Min Avg. Thick (mm) |
Inner Covering Type/Min Avg. Thick (mm) |
Size Range (AWG) |
Insul. Type/Min Avg. Thick (mm) |
Notes |
- Single Conductor
I | A/B | 80 | 300 | - | - | 30-16 | PVC/0.30 | 1, 3, 4 |
I | A/B | 105 | 300 | - | - | 30-10 8-2 |
PVC/0.38 /0.76 |
1, 3, 4 |
I | A/B | 105 | 600 | - | - | 30-10 8 6-2 1-4/0 |
PVC/0.76 /1.14 /1.52 /2.03 |
1, 3, 4 |
I | A/B | 105 | 300 | - | - | 32-16 | SR-PVC/ 0.22 |
1, 3, 4 |
- Multiple Conductor/Round
I/II | A/B | 80 | 300 | PVC/0.76 | PVC/0.35 | 32-16 | PVC/0.38 | 1, 2, 3, 4, 5, 6 |
I/II | A/B | 80 | 300 | PVC/0.76 | PVC/0.35 | 32-12 10 8-6 4-2 1-4/0 |
PE/0.33 /0.45 /0.68 /0.89 /1.07 |
1, 2, 3, 4, 5, 6 |
I/II | A/B | 80 | 1000 | PVC/0.76 | PVC/0.35 | 32-12 10 8-6 4-2 1-4/0 |
PE/0.38 /0.51 /0.76 /1.02 /1.14 |
1, 2, 3, 4, 5, 6 |
I/II | A/B | 80 | 300 | PVC/0.76 | PVC/0.35 | 32-16 | SR-PVC/ 0.22 |
1, 2, 3, 4, 5, 6 |
I/II | A/B | 80 | 300 | PVC/0.76 | PVC/0.35 | 32-12 | PP/0.20 | 1, 2, 3, 4, 5, 6 |
I/II | A/B | 80 | 1000 | PVC/0.76 | PVC/0.35 | 30-10 8 6-2 1-3/0 |
PVC/0.51 /0.76 /1.14 /1.52 |
1, 2, 3, 4, 5, 6 |
I/II | A/B | 90 | 600 | PVC/0.76 | PVC/0.35 | 30-10 8 6-2 1-3/0 |
PVC/0.51 /0.76 /1.14 /1.52 |
1, 2, 3, 4, 5, 6 |
I/II | A/B | 105 | 600 | PVC/1.14 | PVC/0.35 | 30-10 8 6-2 1-4/0 |
PVC/0.51 /0.76 /1.14 /1.52 |
1, 2, 3, 4, 5, 6 |
I/II | A/B | 105 | 1000 | PVC/0.76 | PVC/0.35 | 28-10 | PVC/0.51 | 1, 2, 3, 4, 5, 6 |
I/II | A/B | 80 | 300 | PUR/0.38 | PVC/0.35 PUR/0.35 |
32-16 | PVC/0.38 | 1, 2, 3, 4, 5, 7 |
I/II | A/B | 80 | 300 | PUR/0.38 | PVC/0.35 PUR/0.35 |
32-12 10 8-6 4-2 1-4/0 |
PE/0.33 /0.45 /0.68 /0.89 /1.07 |
1, 2, 3, 4, 5, 7 |
I/II | A/B | 80 | 1000 | PVR/1.14 | PVC/0.35 PUR/0.35 |
32-12 10 8-6 4-2 1-4/0 |
PE/0.38 /0.51 /0.76 /1.02 /1.07 |
1, 2, 3, 4, 5, 7 |
I/II | A/B | 80 | 300 | PUR/0.38 | PVC/0.35 PUR/0.35 |
32-16 | SR-PVC /0.22 |
1, 2, 3, 4, 5, 7 |
I/II | A/B | 80 | 300 | PUR/0.38 | PVC/0.35 PUR/0.35 |
32-12 | PP/0.20 | 1, 2, 3, 4, 5, 7 |
I/II | A/B | 80 | 300 | PUR/0.38 | PVC/0.35 PUR/0.35 |
32-20 19-16 15-10 8-6 4-2 |
TPE/0.20 /0.25 /0.30 /0.41 /0.56 |
1, 2, 3, 4, 5, 7 |
I/II | A/B | 80 | 600 | PUR/1.14 | PVC/0.35 PUR/0.35 |
32-12 10 8-6 4-2 1-4/0 |
TPE/0.25 /0.38 /0.51 /0.76 /1.02 |
1, 2, 3, 4, 5, 7 |
I/II | A/B | 80 | 1000 | PUR/1.14 | PVC/0.35 PUR/0.35 |
32-20 19-16 15-10 8-6 4-2 1-1/0 |
TPE/0.30 /0.36 /0.41 /0.56 /0.71 /0.84 |
1, 2, 3, 4, 5, 7 |
I/II | A/B | 80 | 1000 | PUR/1.14 | PVC/0.35 PUR/0.35 |
30-10 8 6-2 1-3/0 |
PVC/0.51 /0.76 /1.14 /1.52 |
1, 2, 3, 4, 5, 7 |
I/II | A/B | 80 | 1000 | PUR/1.14 | PUR/0.80 | 28-20 19-16 15-10 9-6 5-2 1-4/0 |
PP/0.30 /0.36 /0.41 /0.56 /0.71 /0.84 |
1, 2, 3, 4, 5, 6 |
Notes:
- Insulation in all colours except clear and translucent.
- Jacket in all colours except clear and translucent.
- Flame rating FT1.
- Flame rating FT2.
- Optional shield.
- Optional covering.
- Optional PVC or PUR covering.
/lb
Contact an
Expert
We’re always here to help. Let’s talk.
We’re here to answer your questions and help you get started right away. Call or send us a message anytime.