Customer Class File Number
Mini Motor s.p.a.
Via E. Fermi 5
Bagnolo in Piano (RE)
Reggio Emilia
Italy
42011
4211-01
MOTORS AND GENERATORS - Motors and Generators
226757

         August 06, 2004)

TO THE REQUIREMENTS OF CSA STD. C22.2 NO. 100-M95

?   Squirrel-cage induction motors, permanently connected, tefc, horizontal or vertical, foot and/or flange mounted,  480 V or less, single or 3-ph, ambient 40 ?C,  50/60 Hz, Ins. Cl. N (200), or H (180) or F (155),  2, 4,  poles, flange B5 or B14, external diameter 80 or 95mm.

   Motor model is composed by the following: SERIES + OPTIONAL REDUCTOR + OPTION + MOTOR TYPE

Single phase 2 poles 100V 50/60Hz

Series

Motor type

P (W) (50/60)

I (A) (50/60)

Rpm (50/60)

Optional Reductor

BC2000

M

64 / 72

0,62 / 0,74

2500 / 3000

 

BCE2000

 

AM

40

28 / 34

0,60 / 0,72

2600 / 3100

--

AC

E , S

ME

--

AM

66

70 / 84

0,78 / 0,94

2600 / 3100

--

AC

E , S

ME

 

AM

100P

96 / 115

0,94 / 1,13

2600 / 3100

--

AC

E, S

MC

E

ME

--

AM

160P2

120 / 144

1,25 / 1,50

2600 / 3100

--

AC

E , S

MC

E

ME

--

AM

180M2

150 / 180

1,56 / 1,88

2700 / 3240

--

PA

E

ME

--

AM

240M3

225 / 270

2,37 / 2,84

2700 / 3240

--

MC

E

PA

E

PC

E

ME

--

AM

330M4

328 / 393

3,45 / 4,15

2700 / 3240

--

PA

E

PC

E

ME

--

Options :                 K = Brake (24 Vdc or 230 Vac)
                                 
R  = Tacho Hall
                                 
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

Single phase 2 poles 240V 50/60Hz

Series

Motor type

P (W) (50/60)

I (A) (50/60)

Rpm (50/60)

Optional Reductor

BC2000

M

64 / 72

0,26 / 0,31

2500 / 3000

--

BCE2000

--

AM

40

28 / 34

0,25 / 0,30

2600 / 3100

--

AC

E , S

ME

--

AM

66

70 / 84

0,33 / 0,39

2600 / 3100

--

AC

E , S

ME

--

AM

 

100P

96 / 115

0,39 / 0,47

2600 / 3100

--

AC

E, S

MC

E

ME

--

AM

 

160P2

120 / 144

0,52 / 0,62

2600 / 3100

--

AC

E , S

MC

E

ME

--

AM

180M2

150 / 180

0,65 / 0,78

2700 / 3240

--

PA

E

ME

--

AM

240M3

225 / 270

0,99 / 1,18

2700 / 3240

--

MC

E

PA

E

PC

E

ME

--

AM

 

330M4

328 / 393

1,44 / 1,72

2700 / 3240

--

PA

E

PC

E

ME

--

Options :                 K = Brake (24 Vdc or 230 Vac)
                                 
R  = Tacho Hall
                                 
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

Single phase 4 poles 100V 50/60Hz

Series

Motor type

P (W) (50/60)

I (A) (50/60)

Rpm (50/60)

Optional Reductor

AM

35

38 / 46

0,55 / 0,66

1200 / 1440

--

AC

E , S

ME

--

AM

44

43 / 52

0,60 / 0,71

1200 / 1440

--

AC

E , S

ME

--

AM

 

80P

67 / 80

0,76 / 0,91

1200 / 1440

--

AC

E, S

MC

E

ME

--

 

AM

110P2

78 / 94

0,94 / 1,13

1200 / 1440

--

AC

E , S

MC

E

ME

--

AM

130M2

96 / 115

1,04 / 1,24

1250 / 1500

--

PA

E

ME

--

AM

165M3

115 / 138

1,22 / 1,46

1250 / 1500

--

MC

E

PA

E

PC

E

ME

--

AM

220M4

160 / 192

1,61 / 1,93

1250 / 1500

--

PA

E

PC

E

ME

--

Options :                 K = Brake (24 Vdc or 230 Vac)
                                 
R  = Tacho Hall
                                 
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

Single phase 4 poles 240V 50/60Hz

AM

35

38 / 46

0,23 / 0,28

1200 / 1440

--

AC

E , S

ME

--

AM

44

43 / 52

0,25 / 0,30

1200 / 1440

--

AC

E , S

ME

--

AM

80P

67 / 80

0,32 / 0,38

1200 / 1440

--

AC

E , S

MC

E

ME

--

AM

110P2

78 / 94

0,39 / 0,47

1200 / 1440

--

AC

E, S

MC

E

ME

--

AM

130M2

96 / 115

0,43 / 0,51

1250 / 1500

--

PA

E

ME

--

AM

165M3

115 / 138

0,51 / 0,61

1250 / 1500

--

MC

E

PA

E

PC

E

ME

--

AM

220M4

160 / 192

0,67 / 0,81

1250 / 1500

--

PA

E

PC

E

ME

-

Options :                 K = Brake (24 Vdc or 230 Vac)
                                 
R  = Tacho Hall
                                 
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

Three-phase 2 poles 100/173 ;  50/60Hz

Series

Motor type

P (W) (50/60)

I (A) (50/60)

Rpm (50/60)

Optional Reductor

BC2000

T

66 / 79

0,60-0,34 (50)

0,72-0,41 (60)

2500 / 3000

 

BCE2000

 

AM

72T

54 / 65

0,51-0,29 (50)

0,61-0,35 (60)

2600 / 3100

--

AC

E , S

ME

--

AM

244PT

120 / 144

1,20-0,69 (50)

1,44-0,82 (60)

2600 / 3100

--

AC

E, S

MC

E

ME

 

AM

320P2T

152 / 182

1,42-0,82 (50)

1,71-0,99 (60)

2600 / 3100

--

AC

E , S

MC

E

ME

--

AM

260M2T

140 / 168

1,15-0,66 (50)

1,38-0,80  (60)

2700 / 3240

--

PA

E

ME

--

AM

440M3T

278 / 334

2,07-1,20 (50)

2,48-1,43 (60)

2700 / 3240

--

MC

E

PA

E

PC

E

ME

--

AM

 

530M4T

390 / 468

3,22-1,86 (50)

3,86-2,23 (60)

2700 / 3240

--

PA

E

PC

E

ME

--

Options :                 K = Brake (24 Vdc or 230 Vac)
                                 
R  = Tacho Hall
                                 
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

Three-phase 2 poles 277/480 50/60Hz

Series

Motor type

P (W) (50/60)

I (A) (50/60)

Rpm (50/60)

Optional Reductor

BC2000

T

66 / 79

0,22-0,13 (50)

0,27-0,16 (60)

2500 / 3000

 

BCE2000

 

AM

72T

54 / 65

0,18-0,11 (50)

0,22-0,13 (60)

2600 / 3100

--

AC

E , S

ME

--

AM

244PT

120 / 144

0,43-0,25 (50)

0,52-0,30 (60)

2600 / 3100

--

AC

E, S

MC

E

ME

--

AM

320P2T

152 / 182

0,51-0,30 (50)

0,62-0,36 (60)

2600 / 3100

--

AC

E , S

MC

E

ME

--

AM

260M2T

140 / 158

0,42-0,24 (50)

0,50-0.29 (60)

2700 / 3240

--

PA

E

ME

--

AM

440M3T

278 / 334

0,75-0,43 (50)

0,90-0,52 (60)

2700 / 3240

--

MC

E

PA

E

PC

E

ME

--

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AM

530M4T

390 / 468

1,16-0,67 (50)

1,39-0,81 (60)

2700 / 3240

--

PA

E

PC

E

ME

--

Options :                 K = Brake (24 Vdc or 230 Vac)
                                 
R  = Tacho Hall
                                 
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

Three-phase 4 poles 100/173 50/60Hz

Series

Motor type

P (W) (50/60)

I (A) (50/60)

Rpm (50/60)

Optional Reductor

AM

66T

46 / 55

0,44-0,25 (50)

0,52-0,30 (60)

1200 / 1440

--

AC

E , S

ME

--

AM

110PT

60 / 72

0,57-0,33 (50)

0,69-0,40 (60)

1200 / 1440

--

AC

E, S

MC

E

ME

--

AM

145P2T

72 / 86

0,74-0,42 (50)

0,88-0,51 (60)

1200 / 1440

--

AC

E , S

MC

E

ME

--

AM

140M2T

100 / 120

0,76-0,44 (50)

0,91-0,53 (60)

1200 / 1400

--

PA

E

ME

--

MC 230P3T 150/180

1,33-0,77 (50)

1,60-0,92 (60)

1250/1500 E

AM

230M3T

150 / 180

1,33-0,77 (50)

1,60-0,92 (60)

1250 / 1500

--

MC

E

PA

E

PC

E

ME

--

AM

 

310M4T

190 / 228

1,79-1,04 (50)

2,15-1,24 (60)

1250 / 1500

--

PA

E

PC

E

ME

--

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

 

Options :              K = Brake (24 Vdc or 230 Vac)
                              
R  = Tacho Hall
                               
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

Three-phase 4 poles 277/480 50/60Hz

Series

Motor type

P (W) (50/60)

I (A) (50/60)

Rpm (50/60)

Optional Reductor

AM

66T

46 / 55

0,16-0,09 (50)

0,19-0,11 (60)

1200 / 1440

--

AC

E , S

ME

--

AM

 

110PT

46 / 55

0,21-0,12 (50)

0,25-0,14 (60)

1200 / 1440

--

AC

E, S

MC

E

ME

--

AM

 

145P2T

72 / 86

0,27-0,15 (50)

0,32-0,18 (60)

1200 / 1440

--

AC

E , S

MC

E

ME

--

AM

140M2T

100 / 120

0,27-0,16 (50)

0,33-0,19 (60)

1200 / 1400

--

PA

E

ME

--

MC 230P3T 150/120 0,48-0,16 (50)

0,58-0,33 (60)

1250/1500 E

 

 

 

 

 

 

 

 

 

 

 

 

AM

230M3T

150 / 180

0,48-0,28 (50)

0,58-0,33 (60)

1250 / 1500

--

MC

E

PA

E

PC

E

ME

--

AM

310M4T

190 / 228

0,64-0,37 (50)

0,78-0,45 (60)

1250 / 1500

--

PA

E

PC

E

ME

--

 

 

 

 

 

 

Options :                 K = Brake (24 Vdc or 230 Vac)
                                 
R  = Tacho Hall
                                 
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

?    Brushless motors, permanently connected, tenv, horizontal or vertical, foot and/or flange mounted,  230 V or less, 3-ph, ambient 40 ?C,  50/60 Hz, Ins. Cl. N (200) or H (180) OR F (155);  4  poles,   external diameter 35 to 100 mm.

AC 4 poles brushless 230V

Motor type

P (W)

I (A)@4000 Rpm Flangiato.

Rpm

series

CONNECTION

optional

BS 35/30

45

0,22

4000

E

RC, RP

K

BS 35/60

80

0,39

4000

E

RC, RP

K

BS 45/35

105

0,51

4000

E

RC, RP

K

BS 45/70

145

0,71

4000

E

RC, RP

K

BS 55/50

190

0,94

4000

E

RC, RP

K

BS 55/100

330

1,65

4000

E

RC, RP

K

BS 80/50

400

2

4000

E

RC, RP

K

BS 80/100

700

3,5

4000

E

RC, RP

K

Options :                 K = Brake (24 Vdc or 230 Vac)
                                 
R  = Tacho Hall
                                 
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

?        DC brush motors, permanently connected, tenv, horizontal or vertical, foot and/or flange mounted,  12 –24V DC ambient 40 ?C,  Ins. Cl. H (180) or F (155)  ;  2 poles, flange B5 or B14, external diameter 80 or 95mm.

DC 2 poles 12/24V

series

Motor type

P (W)

I (A)

Rpm

Optional Reductor

MCC

12MP

60

5

2800

E

ACC

E , S

BC2000

 

BCE2000

 

ME

--

MCC

24MP

60

2,5

2800

E

ACC

E , S

BC2000

 

BCE2000

 

ME

--

MCC

12MP2

120

5

2800

E

ACC

E , S

PCC

E

ME

--

MCC

24MP2

120

10

2800

E

ACC

E , S

PCC

E

ME

--

PAC

12MP3N

115

9,6

2800

E

MCC

E

PCC

E

ME

--

PAC

24MP3N

115

4,8

2800

E

MCC

E

PCC

E

ME

--

PAC

12MP4N

230

19,2

2800

E

MCC

E

PCC

E

ME

--

PAC

24MP4N

230

9,6

2800

E

MCC

E

PCC

E

ME

--

Options :                 K = Brake (24 Vdc or 230 Vac)
                                 
R  = Tacho Hall
                                 
RR = Encoder 512 or 50 Imp. (5 or 24 Vdc)

Notes:

1.    Certified conduit fittings to convert from PG/metric to  NPT tread size shall be supplied with  the motors and shall be used during  the final installation.



/jvdh