Customer Class File Number
Weidmueller Interface GmbH & Co. KG
Klingenbergstrasse 26
Detmold
North Rhine-Westphalia
Germany
32758
5318-81
POWER SUPPLIES - For Hazardous Locations - Certified to U.S. Standards
200039


Class I, Division 2, Groups A, B, C, and D, T4

Component type power supply for use in industrial control equipment

ModelsInput Voltage (VAC)Input Frequency (Hz)Input Current (A)Output Voltage (VDC)Output Current (A)
PRO INSTA 16W 24V 0.7A100~24050‑600.25‑0.45240.7
PRO INSTA 30W 24V 1.3A100~24050‑600.5‑1.0241.3
PRO INSTA 30W 12V 2.6A100~24050‑600.5‑1.0122.6
PRO INSTA 30W 5V 6A100~24050‑600.5‑1.056
PRO INSTA 60W 24V 2.5A100~24050‑600.7‑1.5242.5
PRO INSTA 60W 12V 5A100~24050‑600.7‑1.5125
PRO INSTA 90W 24V 3.8A100~24050‑601.2‑2.4243.8
PRO INSTA 96W 24V 4A100~24050‑601.2‑2.5244
PRO INSTA 96W 48V 2A100~24050‑601.2‑2.5482

Conditions of Acceptability:

1. The above models are certified only as components of other certified equipment, where the suitability of the combination of the final equipment must be determined by CSA.

2. The above model has been found suitable for operation at an ambient of -25 to 70C (>55C, Derating: 2.5%/K);

3. The above models are comply with Class 2 output, excepted models PRO INSTA 96W 24V 4A, and PRO INSTA 96W 48V 2A.

4. The above model is intended for use in a controlled environment (Pollution Degree 2).

5. The above models should be mounted in a vertical location.

6. Installation in accordance with the CEC Part I or NEC as applicable.

7. The above models must be used in a suitable degree of protection enclosure to meet requirements in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction. 

Class I, Division 2, Groups A, B, C, D T4

DC buffer module

Models
PRO DC BUFFER 24V 20A

InputOutputBuffer OutputBuffer TimeTemperature
VDCAVDCA
24V26A24V20A

22V/Vin-1V, 20A;

Power boost 25A (≤45°C)
20A,0.2S-25°C…+70°C (?+60°C Derating:2.5%/K)

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations and the enclosure can only be opened by use of a tool, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. The ambient temperature of -20°C to +70°C applies to the enclosure internal air surrounding the equipment.
  3. The final enclosure must bear the following warning: “DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS” and “DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  4. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO DC BUFFER 24V 40A

InputOutputBuffer OutputBuffer TimeTemperature
VDCAVDCA
24V46A24V40A

22V/Vin-1V, 40A;

Power boost 45A (≤45°C)
40A,0.2S-25°C…+70°C (?+60°C Derating:2.5%/K)

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations and the enclosure can only be opened by use of a tool, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. The ambient temperature of -20°C to +70°C applies to the enclosure internal air surrounding the equipment.
  3. The final enclosure must bear the following warning: “DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS” and “DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  4. Installation shall be in accordance with the CEC Part I or NEC as applicable.

To the requirements of
C22.2 NO. 213-17, CAN/CSA-C22.2 No. 61010-1-12, UL 61010-1 (Third Edition), UL 121201 (Ninth Edition), CAN/CSA-C22.2 61010-2-201:18, Rev

Class I, Division 2, Groups A, B, C, D T4

Power supply

Models
PRO TOPDC 24V/24V 5A

InputOutputTemperature
VHzAVDCA
24 VDC-5.7245

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOPDC 24V/24V 5A EX

InputOutputTemperature
VHzAVDCA
24 VDC-5.7245

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOPDC 24V/24V 10A
PRO TOPDC 24V/24V 10A U+

InputOutputTemperature
VHzAVDCA
24 VDC-112410

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOPDC 24V/24V 10A EX

InputOutputTemperature
VHzAVDCA
24 VDC-112410

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOPDC 24V/24V 20A

InputOutputTemperature
VHzAVDCA
24 VDC-222420

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOPDC 24V/24V 20A EX

InputOutputTemperature
VHzAVDCA
24 VDC-222420

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOPDC 24V/48V 10A

InputOutputTemperature
VHzAVDCA
24 VDC-224810

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOP2 120W 24V 5A UW

InputOutputTemperature
VHzAVDCA
100~240 VAC50-602.0-1.0245

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

 

Y 230/400~500VAC,

2W+PE

50-600.7-0.5

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOP2 120W 24V 5A UW EX

InputOutputTemperature
VHzAVDCA
100~240 VAC50-602.0-1.0245

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

 

Y 230/400~500VAC,

2W+PE

50-600.7-0.5

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOP2 240W 24V 10A UW

InputOutputTemperature
VHzAVDCA
100~240 VAC50-603-1.32410

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

 

Y 230/400~500VAC,

2W+PE

50-601.4-0.8

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOP2 240W 24V 10A UW EX

InputOutputTemperature
VHzAVDCA
100~240 VAC50-603-1.32410

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

 

Y 230/400~500VAC,

2W+PE

50-601.4-0.8

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

Models
PRO TOP2 240W 48V 5A UW

InputOutputTemperature
VHzAVDCA
100~240 VAC50-603-1.3485

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

 

Y 230/400~500VAC,

2W+PE

50-601.4-0.8

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.