Customer Class File Number
Weidmueller Interface GmbH & Co. KG
Klingenbergstrasse 26
Detmold
North Rhine-Westphalia
Germany
32758
5318-81
POWER SUPPLIES - For Hazardous Locations - Certified to U.S. Standards
200039

  • Class I, Division 2, Groups A, B, C, and D, T4;

    Component type power supply for use in industrial control equipment

Model

Input

Output

Vac

Hz

A

Vdc

A

PRO INSTA 16W 24V 0.7A

100~240

50-60

0.25-0.45

24

0.7

PRO INSTA 30W 24V 1.3A

100~240

50-60

0.5-1.0

24

1.3

PRO INSTA 30W 12V 2.6A

100~240

50-60

0.5-1.0

12

2.6

PRO INSTA 30W 5V 6A

100~240

50-60

0.5-1.0

5

6

PRO INSTA 60W 24V 2.5A

100~240

50-60

0.7-1.5

24

2.5

PRO INSTA 60W 12V 5A

100~240

50-60

0.7-1.5

12

5

PRO INSTA 90W 24V 3.8A

100~240

50-60

1.2-2.4

24

3.8

PRO INSTA 96W 24V 4A

100~240

50-60

1.2-2.5

24

4

PRO INSTA 96W 48V 2A

100~240

50-60

1.2-2.5

48

2

Conditions of Acceptability:

1. The above models are certified only as components of other certified equipment, where the suitability of the combination of the final equipment must be determined by CSA.

2. The above model has been found suitable for operation at an ambient of -25 to 70C (>55C, Derating: 2.5%/K);

3. The above models are comply with Class 2 output, excepted models PRO INSTA 96W 24V 4A, and PRO INSTA 96W 48V 2A.

4. The above model is intended for use in a controlled environment (Pollution Degree 2).

5. The above models should be mounted in a vertical location.

6. Installation in accordance with the CEC Part I or NEC as applicable.

7. The above models must be used in a suitable degree of protection enclosure to meet requirements in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction. 

 

Class I, Division 2, Groups A, B, C, D T4

Power supply, model name and ratings as follows:

Model

Input

Output

Temperature

V

Hz

A

VDC

A

PRO TOPDC 24V/24V 5A

24 VDC

-

5.7

24

5

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

PRO TOPDC 24V/24V 5A EX

24 VDC

-

5.7

24

5

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

PRO TOPDC 24V/24V 10A

24 VDC

-

11

24

10

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

PRO TOPDC 24V/24V 10A EX

24 VDC

-

11

24

10

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

PRO TOPDC 24V/24V 20A

24VDC

-

22

24

20

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

PRO TOPDC 24V/24V 20A EX

24 VDC

-

22

24

20

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

PRO TOPDC 24V/48V 10A

24 VDC

-

22

48

10

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

PRO TOP2 120W 24V 5A UW

100~240 VAC

50-60

2.0-1.0

24

5

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Y 230/400~500VAC,

2W+PE

50-60

0.7-0.5

PRO TOP2 120W 24V 5A UW EX

100~240 VAC

50-60

2.0-1.0

24

5

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Y 230/400-500VAC, 2W+PE

50-60

0.7-0.5

PRO TOP2 240W 24V 10A UW

100~240 VAC

50-60

3-1.3

24

10

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Y 230/400~500VAC,

2W+PE

50-60

1.4-0.8

PRO TOP2 240W 24V 10A UW EX

100~240 VAC

50-60

3-1.3

24

10

-40°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Y 230/400~500VAC,

2W+PE

50-60

1.4-0.8

PRO TOP2 240W 48V 5A UW

100~240 VAC

50-60

3-1.3

48

5

-25°C…+60°C,

+60°C…+70

(Derating:2.5%/K)

Y 230/400~500VAC,

2W+PE

50-60

1.4-0.8

 

Conditions of Acceptability:

 

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. When in use, do not adjust the switch and Potentiometer unless the area is known to be non-hazardous.
  3. Installation shall be in accordance with the CEC Part I or NEC as applicable.

Class I, Division 2, Groups A, B, C, D T4

DC buffer module, module name and ratings as follows:

Model

Input

Output

Buffer output

Buffer time

Temperature

VDC

A

VDC

A

PRO DC BUFFER 24V 20A

24V

26A

24V

20A

22V/Vin-1V, 20A;

Power boost 25A (≤45°C)

20A,0.2S

-25°C…+70°C (>+60°C Derating:2.5%/K)

PRO DC BUFFER 24V 40A

24V

46A

24V

40A

22V/Vin-1V, 40A,

Power boost 45A (≤45°C)

40A,0.2S

-25°C…+70°C(>+60°C Derating:2.5%/K)

 

Conditions of Acceptability:

  1. The equipment shall be installed in a suitable degree of protection enclosure to meet requirement in Class I, Division 2 locations and the enclosure can only be opened by use of a tool, where final assembly is subject to acceptance by the local authority having jurisdiction.
  2. The ambient temperature of -20°C to +70°C applies to the enclosure internal air surrounding the equipment.
  3. The final enclosure must bear the following warning: “DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS” and “DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  4. Installation shall be in accordance with the CEC Part I or NEC as applicable.
Cert Rec - 200039-531881