Customer Class File Number
Weidmueller Interface GmbH & Co. KG
Klingenbergstrasse 26
Detmold
North Rhine-Westphalia
Germany
32758
5311-03
POWER SUPPLIES - Component Type
200039


Component type DIN Rail power supply*.

ModelsInput Voltage (VAC)Input Current (A)Input Frequency (Hz)Output Voltage (VDC)Output Current Output Power (W max)Input Voltage (VDC)
CP SNT 48W xxV yyA**100‑2401,2‑0.550/6012‑48max 4‑1A48
110‑370

  • **Where "xx"stands for the DC output voltage and can be any value between 12-48 and "yy"stands for the DC output current. 

Note(*): (*)The products have been certified as components where the suitability of the combination with the end use product shall be re-evaluated.

ModelsInput Voltage (VAC)Input Current (A)Input Frequency (Hz)Output Voltage (VDC)Output Current (A)Input Voltage (VDC)
CP SNT 25W 5V 5A100‑2400.7‑0.350/6055
110‑370

  • **Where "xx"stands for the DC output voltage and can be any value between 12-48 and "yy"stands for the DC output current. 

Note(*): (*)The products have been certified as components where the suitability of the combination with the end use product shall be re-evaluated.

To the requirements of
CSA C22.2 NO. 107.1-01

DC Diode module, open type, DIN‑rail mounted.

ModelsInput Voltage (VDC)Input CurrentOutput Voltage (VDC)Output Current Surrounding Air Temperature (°C max)
CP M DM2018‑302.0 A or 1.0 A18‑30 2.0 A or 1.0 A70
CP M DM4018‑302.0 A or 1.0 A18‑30 2.0 A or 1.0 A70

 

Relay Output (Contact), Maximum
VoltageCurrentLoad Type
30 Vdc1 AResistive
30 Vdc1 AResistive

  Notes:

         1. These devices are mounted on horizontal DIN-rail.

         2. The input source for this device is external Limited Voltage power supply.

         3. These devices are suitable for field wiring and for use in Pollution Degree 2 environment.

To the requirements of
CSA C22.2 NO. 107.1:16

Component type power supply for use in industrial control equipment.

ModelsInput Voltage (VAC)Input Frequency (Hz)Input Current (A)Output Voltage (VDC)Output Current (A)
PRO INSTA 16W 24V 0.7A100~24050‑600.25‑0.45240.7
PRO INSTA 30W 12V 2.6A100~24050‑600.5‑1.0122.6
PRO INSTA 30W 5V 6A100~24050‑600.5‑1.056
PRO INSTA 60W 24V 2.5A100~24050‑600.7‑1.5242.5
PRO INSTA 60W 12V 5A100~24050‑600.7‑1.5125
PRO INSTA 90W 24V 3.8A100~24050‑601.2‑2.4243.8
PRO INSTA 96W 48V 2A100~24050‑601.2‑2.5482

Notes:

1. The above models are certified only as components of other certified equipment, where the suitability of the combination is to be determined by CSA;

2. End product must provide a proper electrical and fire enclosure.

3. The above model has been found suitable for operation at an ambient of -25 to 70°C  (>55°C , Derating: 2.5%/K);

4. The above models are comply with Class 2 output, excepted models PRO INSTA 96W 24V 4A, and PRO INSTA 96W 48V 2A.

5. The above model is intended for use in a controlled environment (Pollution Degree 2).

6. The above models should be mounted in a vertical location.

ModelsInput Voltage (VAC)Input Frequency (Hz)Output Voltage (VDC)Input Current (A)Output Current (A)
PRO INSTA 30W 24V 1.3A100~24050‑60240.5‑1.01.3
PRO INSTA 96W 24V 4A100~24050‑60241.2‑2.54

Notes:

1. The above models are certified only as components of other certified equipment, where the suitability of the combination is to be determined by CSA;

2. End product must provide a proper electrical and fire enclosure.

3. The above model has been found suitable for operation at an ambient of -25 to 70°C  (>55°C , Derating: 2.5%/K);

4. The above models are comply with Class 2 output, excepted models PRO INSTA 96W 24V 4A, and PRO INSTA 96W 48V 2A.

5. The above model is intended for use in a controlled environment (Pollution Degree 2).

6. The above models should be mounted in a vertical location.