Customer Class File Number
Superior Radiant Products Ltd.
563 Barton Street
Stoney Creek
Ontario
Canada
L8E 5S1
2902-09
COMMERCIAL HEATERS (GAS) - Infrared, Unvented and Vented
112168_0_000


INFRA‑RED HEATERS

SUPERIOR RADIANT PRODUCTS

Model(s)
GA301, GA301T, GA301H

*ALTITUDE:  N = 0 to 2,000 feet; H = 2,000 to 4,500 feet above sea level.

​​​​​​

SUPERIOR RADIANT PRODUCTS

Model(s)Altitude Input Rating (BTU/HR)Type
(UA, UAB, UAW, UX, LA, LX, UXR, LXR, LXS, LXSR, WTH)-40N & H40,000Vented (Forced Draft) Unvented, Suspended
(UA, UAB, UAW, UX, LA, LX, UXR, LXR, LXS, LXSR, WTH, 750)-60N & H60,000Vented (Forced Draft) Unvented, Suspended
(UA, UAB, UAW, UX, LA, LX, UXR, LXR, LXS, LXSR, WTH, NGF)-80N & H80,000Vented (Forced Draft) Unvented, Suspended
(UA, UAB, UAW, UX, LA, LX, UXR, LXR, LXS, LXSR, WTH, 750)-100N & H100,000Vented (Forced Draft) Unvented, Suspended
(UA, UAB, UAW, UX, UXR, WTH)-125N & H125,000Vented (Forced Draft) Unvented, Suspended
(UA, UAB, UAW, UX, UXR, WTH)-150N & H150,000Vented (Forced Draft) Unvented, Suspended
(UA, UAB, UAW, UX, UXR, WTH)-175N & H175,000Vented (Forced Draft) Unvented, Suspended
(UA, UAB, UAW, UX, UXR, WTH)-205N & H205,000Vented (Forced Draft) Unvented, Suspended
(UA, UAB, UAW, UX, UXR, WTH)-220N & H220,000Vented (Forced Draft) Unvented, Suspended

For Use With Propane Gas

 

The models listed for use with Natural Gas are also for use with Propane Gas with the same ratings, clearances and trade name, at the same altitude.

*ALTITUDE: N = 0 to 2,000 feet; H = 2,000 to 4,500 feet above sea level.

Superior Radiant Products and IR Energy

Model(s)Altitude Input Rating (BTU/HR)Type
(MA, MX, LMA, LMX, UABM MXR, LMXR, LMXS, LMXSR, TA, TX, TXR, LTA, LTX, LTXS, LTXSR, WTS  )-40N & H30,000 ‑40,000Vented (Forced Draft) Unvented, Suspended
(MA, MX, LMA, LMX, UABM MXR, LMXR, LMXS, LMXSR, TA, TX, TXR, LTA, LTX, LTXS, LTXSR, WTS  )-60N & H45,000 ‑60,000Vented (Forced Draft) Unvented, Suspended
(MA, MX, LMA, LMX, UABM MXR, LMXR, LMXS, LMXSR, TA, TXR, TX, LTA, LTX, LTXS, LTXSR, WTS  )-80N & H60,000 ‑80,000Vented (Forced Draft) Unvented, Suspended
(MA, MX, LMA, LMX, UABM, MXR, LMXR, LMXS, LMXSR, TA, TX, TXR, LTA, LTX, LTXS, LTXSR, WTS  )-100N & H75,000 ‑100,000Vented (Forced Draft) Unvented, Suspended
(MA, MX, MXR, UABM, TA, TX, TXR, WTS)-125N & H95,000 ‑125,000Vented (Forced Draft) Unvented, Suspended
(MA, MX, MXR, UABM, TA, TX, TXR, WTS)-150N & H115,000 ‑150,000Vented (Forced Draft) Unvented, Suspended
(MA, MX, MXR, UABM, TA, TX, TXR, WTS)-175N & H130,000 ‑175,000Vented (Forced Draft) Unvented, Suspended
(MA, MX, MXR, UABM, TA, TX, TXR, WTS)-205N & H160,000 ‑205,000Vented (Forced Draft) Unvented, Suspended
(MA, MX, MXR, UABM, TA, TX, TXR)-220N & H165,000 ‑220,000Vented (Forced Draft) Unvented, Suspended
THE-80N*N & H55,000 ‑80,000Vented (Forced Draft) Unvented, Suspended
THE-140N*N & H85,000 ‑135,000Vented (Forced Draft) Unvented, Suspended
THE-200N*N & H140,000 ‑195,000Vented (Forced Draft) Unvented, Suspended
ETSV-80*N & H50,000‑80,000Vented (Forced Draft) Unvented, Suspended
ETSV-80#N & H49,000‑79,000Vented (Forced Draft) Unvented, Suspended
ETSV-40N & H23,000‑38,500Vented (Forced Draft) Unvented, Suspended

* Note: Natural Gas only model.

# Note: Propane Gas only model

*ALTITUDE: N = 0 to 2,000 feet; H = 2,000 to 4,500 feet above sea level.

​​​​​​​

SUPERIOR RADIANT PRODUCTS

Model(s)Altitude Input Rating (BTU/HR)Type
S3, SE3N & H34,000Un‑vented, Suspended
S6, SE6N & H66,000Un‑vented, Suspended
S9, SE9N & H99,000Un‑vented, Suspended
S12, SE12N & H132,000Un‑vented, Suspended
S16, SE16N & H160,000Un‑vented, Suspended
S3, SE3N & H30,000Un‑vented, Suspended
S6, SE6N & H60,000Un‑vented, Suspended
S9, SE9N & H90,000Un‑vented, Suspended
S12, SE12N & H120,000Un‑vented, Suspended

*ALTITUDE:  n = 0 to 2,000 feet; H = 2,000 to 4,500 feet above sea level.

SUPERIOR RADIANT PRODUCTS

Model(s)Altitude Input Rating (BTU/HR)Type
GA301, GA301TN46,000‑53,000Un‑vented, Patio
GA301HN46,000‑53,000Un‑vented, Suspended Patio
GA301M, GA301MPN53,000Un‑vented, Patio

*ALTITUDE:  N = 0 to 2,000 feet; H = 2,000 to 4,500 feet above sea level.

​​​​​​

SUPERIOR RADIANT PRODUCTS

Model(s)Altitude Max Input Rating (BTU/HR)Min Input Rating (BTU/HR)Type
WTO 100N100,00075,000Un‑vented, Suspended
WTO 100N100,00075,000Un‑vented, Suspended

*ALTITUDE: N = 0 to 2,000 feet; H = 2,000 to 4,500 feet above sea level.

SUPERIOR RADIANT PRODUCTS

Model(s)Altitude Input Rating (BTU/HR)Type
HAB/M20N15,000‑20,000Un‑vented, Patio
HAB/M40N32,000‑40,000Un‑vented, Patio
HAB/M50N42,000‑50,000Un‑vented, Patio

*ALTITUDE: N = 0 to 2,000 feet; H = 2,000 to 4,500 feet above sea level.

​​​​​​

Vented Overhead Tube Type Infrared Heaters

SUPERIOR RADIANT PRODUCTS

Model(s)Altitude Electrical RatingMax Input RatingMin Input Rating
PREMIER VSTB, C, D250,00060,000

 

​​​

Gas‑Fired Infra‑Red Heater

PREMIER

Model(s)Altitude Input Rating (BTU/HR)Type
PREMIER VS-VH-20N & H12,000 thru 20,000Vented, Induced, Draft, Suspended
PREMIER VS-VH-40N & H24,000 thru 40,000Vented, Induced, Draft, Suspended
PREMIER VS-VH-60N & H36,000 thru 60,000Vented, Induced, Draft, Suspended
PREMIER VS-VH-80N & H48,000 thru 80,000Vented, Induced, Draft, Suspended
PREMIER VS-VH-120N & H60,000 thru 120,000Vented, Induced, Draft, Suspended

For Use With Propane Gas

The model Premier VS listed for use with Natural Gas are also for use with Propane Gas with the same ratings, clearances and trade name, at the same altitudes.

*ALTITUDE:  N = 0 to 2,000 feet; H = 2,000 to 4,500 feet above sea level.

​​​​​​

To the requirements of
CSA/AM ANSI Z83.19-2017/CSA 2.35-2017, CSA/ANSI Z83.26:20 • CSA 2.37:20


2902‑09 ‑ COMMERCIAL HEATERS (GAS) ‑ Infrared, Unvented and Vented
2902‑89 ‑ COMMERCIAL HEATERS (GAS) ‑ Infrared, Unvented and Vented ‑ Certified to U.S. Standards
For use with Natural Gas

SUPERIOR RADIANT PRODUCTS

Model(s)TypeAltitude (*)Fuel Input (BTU/HR)
GA301, GA301TUn‑ventedN46,000‑53,000
GA301HUnvented, SuspendedN46,000‑53,000
GA301M, GA301MP, GA301MTUnventedN53,000

To the requirements of
ANSI Z83.20-2016/CSA 2.34-2016, CAN1-2.20-M85(R2006), CAN1-2.21(R2003)-M85, ANSI Z21.86-2016 • CSA 2.32-2016, IAS Requirement 7-89-1999


 

MODELS:

 

(UA, UX, UAB, UAW, UABM, MA, MX, UXR, MXR, TA, TX, TXR, WTH, WTS, AUX, ASUX)-(40, 60, 80, 100, 125, 150, 175, 205, 220)

AUXS – (60, 80)

(ATX, ASTX) - (40, 60, 80, 100, 125)

ATXS – (60, 80)

(LA, LX, LMA, LMX, LXR, LXS, LXSR, LMXR, LMXS, LMXSR, LTA, LTX, LTXR, LTXS, LTXSR, ALTA, ASLTA, ALTX, ASLTX, ALX, ASLX) - (40, 60, 80, 100)

*750-(60, 100)              Series-Gas Fired Infra-Red Heaters & Residential Radiant Tube Heaters

UAG, TAG (40, 60)      Series-Gas Fired Infra-Red Heaters & Residential Radiant Tube Heaters

RE (30, 45)                   Series-Gas Fired Infra-Red Heaters & Residential Radiant Tube Heaters

GR (30, 45)                  Series-Gas Fired Infra-Red Heaters & Residential Radiant Tube Heaters

GRT (45)                      Series-Gas Fired Infra-Red Heaters & Residential Radiant Tube Heaters

A(G,M)-(80,115,150,200)

THE - 200N, 140N, 80N

ETSV-80, 60, 40

TVX - (60, 80, 100, 125, 150, 175, 205, 220)

 

 

*Note: The corresponding tube temperatures are below 750oF.