Customer Class File Number
Delta M Corporation
Bethel Valley Industrial Park
1003 Larsen Dr.
Oak Ridge
Tennessee
United States
37830
2258-02
PROCESS CONTROL EQUIPMENT - For Hazardous Locations
095764_0_000

Class I, Div 1, Groups B, C, and D; Class II, Div 1, Groups E, F nd G; Class III, Div 1; Type 4: 

?     Versa-Switch Series Single Channel Level Switch, Models LS51SC- aaa-bb-ccc.cc-ddd-LE-ee (with integral Probe); or Remote version, Model LS51SC-000-00-000.00-ddd-RE-ee with Remote Probe, Model LS51SC- aaa-bb-ccc.cc -000-RP-ee; input rated 24/110/220 Vac, 50/60 hz, 200/84/43 mA; 24 Vdc, 175 mA; relay contact rating 250V ac, 5A max; Temp Code T4A @ Max ambient 40 Deg C; MWP 3000 psi.

 

Model Code:

LS51SC - Single Level Channel Switch series

aaa= Mounting/Process fitting (any alpha/numeric character, not relevant to certification)

bb= Wetted Process Material (S4=304 stainless steel, SL=304L stainless steel, S6=316L stainless steel, A2=alloy 20, HB=hastelloy B, HC=hastelloy C, IO=inconel 600, MN=monel, SM=special material, or TI=titanium)

ccc.cc= Insertion Length (from 000.50 (12.7mm) to 120.00 (3048mm))

ddd= Electronics input power (24D=24Vdc, 24A=24Vac, 110=110Vac or 220=220Vac)

ee= Special Options (FA= failure alarm, HT= high temperature sensor, LT= live tap, MT, medium temperature sensor, RT= RTD output, SW= stainless steel housing w/window, TO thermocouple output, XW= explosion proof window cover; other allowed markings but not relevant to certification: CA, CB, CO, EN, SH, SHF, SPL, TC, TEE, TG and VI).

Zeros in the part number are just place holders with no options available

?     Versa-Switch Series Single Channel Flow Switch, Models FS51SC-XXX-XX-XXX.XX-XXX-LE-XX (with integral Probe); or Remote version, Model FS51SC-000-00-000.00-XXX-RE-XX with Remote Probe, Model FS51SC-XXX-XX-XXX.XX-000-RP-XX; input rated 24/110/220 Vac, 50/60 hz, 200/84/43 mA; 24 Vdc, 175 mA; relay contact rating 250V ac, 5A max; Temp Code T4A @ Max ambient 40 Deg C; MWP 3000 psi. 

Model Code:

FS5100S - Dual Channel Switch series

aaa= Mounting/Process fitting (any alpha/numeric character, not relevant to certification)

bb= Wetted Process Material (S4=304 stainless steel, SL=304L stainless steel, S6=316L stainless steel, A2=alloy 20, HB=hastelloy B, HC=hastelloy C, IO=inconel 600, MN=monel, SM=special material, or TI=titanium)

ccc.cc= Insertion Length (from 000.50 (12.7mm) to 120.00 (3048mm))

ddd= Electronics input power (24D=24Vdc, 24A=24Vac, 110=110Vac or 220=220Vac)

ee= Special Options (FA= failure alarm, HT= high temperature sensor, LT= live tap, MT, medium temperature sensor, RT= RTD output, SW= stainless steel housing w/window, TO thermocouple output, XW= explosion proof window cover; other allowed markings but not relevant to certification: CA, CB, CO, EN, SH, SHF, SPL, TC, TEE, TG and VI).

Zeros in the part number are just place holders with no options available

?     Versa-Switch Series Dual Channel Switch, Models VS5100-XXX-XX-XXX.XX-XXX-LE-XX (with integral Probe); or Remote version, Model VS5100-000-00-000.00-XXX-RE-XX with Remote Probe, Model VS5100-XXX-XX-XXX.XX-000-RP-XX; input rated 24/110/220 Vac, 50/60 hz, 200/84/43 mA; 24 Vdc, 175 mA; relay contact rating 250V ac, 5A max; Temp Code T4A @ Max ambient 40 Deg C; MWP 3000 psi. 

Model Code:

VS51SC - Single Level Switch series

aaa= Mounting/Process fitting (any alpha/numeric character, not relevant to certification)

bb= Wetted Process Material (S4=304 stainless steel, SL=304L stainless steel, S6=316L stainless steel, A2=alloy 20, HB=hastelloy B, HC=hastelloy C, IO=inconel 600, MN=monel, SM=special material, or TI=titanium)

ccc.cc= Insertion Length (from 000.50 (12.7mm) to 120.00 (3048mm))

ddd= Electronics input power (24D=24Vdc, 24A=24Vac, 110=110Vac or 220=220Vac)

ee= Special Options (FA= failure alarm, HT= high temperature sensor, LT= live tap, MT, medium temperature sensor, RT= RTD output, SW= stainless steel housing w/window, TO thermocouple output, XW= explosion proof window cover; other allowed markings but not relevant to certification: CA, CB, CO, EN, SH, SHF, SPL, TC, TEE, TG and VI).

Zeros in the part number are just place holders with no options available 

Notes:

1.  If the process fluid temperature exceeds 40 ?C, the device can not be used in a process atmosphere that has an ignition temperature of 120 ?C increased by the difference of the fluid temperature and 40?C.

?         Microtuf Series Thermal Differential Point Level Switch, Models LS32CS-aaa-bb-ccc.cc-ddd-LE-ee (with integral Probe); or Remote version, Model LS32CS-000-00-000.00-ddd-RE-ee with Remote Probe, Model LS32CS-aaa-bb-ccc.cc -000-RP-ee; input rated 24/110/220V ac, 50/60Hz, 200/85/42mA; 24V dc, 100mA; relay contact rating 250V ac, 5A max; Temp Code T4A @ Max ambient 40 Deg C; MWP 3000 psi. 

Model Code:

LS32CS - Level Switch series

aaa= Mounting/Process fitting (any alpha/numeric character, not relevant to certification)

bb= Wetted Process Material (S4=304 stainless steel, SL=304L stainless steel, S6=316L stainless steel, A2=alloy 20, HB=hastelloy B, HC=hastelloy C, IO=inconel 600, MN=monel, SM=special material, or TI=titanium)

ccc.cc= Insertion Length (from 000.50 (12.7mm) to 120.00 (3048mm))

ddd= Electronics input power (24D=24Vdc, 24A=24Vac, 110=110Vac or 220=220Vac)

ee= Special Options (HT= high temperature sensor, LT= live tap, MT, medium temperature sensor, RT= RTD output, SW= stainless steel housing w/window, TO thermocouple output, XW= explosion proof window cover; other allowed markings but not relevant to certification: CA, CB, CE, CO, EN, SH, SHF, SPL, TC, TEE, TG and VI).

Zeros in the part number are just place holders with no options available 

?         Microtuf Series Thermal Differential Mass Flow Switch, Models FS42CS-aaa-bb-ccc.cc-ddd-LE-ee (with integral Probe); or Remote version, Model FS42CS-000-00-000.00-ddd-RE-ee with Remote Probe, Model FS42CS- aaa-bb-ccc.cc -000-RP-ee; input rated 24/110/220V ac, 50/60Hz, 200/85/42mA; 24V dc, 100mA; relay contact rating 250V ac, 5A max; Temp Code T4A @ Max ambient 40 Deg C; MWP 3000 psi. 

Model Code:

FS42CS - Flow Switch series

aaa= Mounting/Process fitting (any alpha/numeric character, not relevant to certification)

bb= Wetted Process Material (S4=304 stainless steel, SL=304L stainless steel, S6=316L stainless steel, A2=alloy 20, HB=hastelloy B, HC=hastelloy C, IO=inconel 600, MN=monel, SM=special material, or TI=titanium)

ccc.cc= Insertion Length (from 000.50 (12.7mm) to 120.00 (3048mm))

ddd= Electronics input power (24D=24Vdc, 24A=24Vac, 110=110Vac or 220=220Vac)

ee= Special Options (HT= high temperature sensor, LT= live tap, MT, medium temperature sensor, RT= RTD output, SW= stainless steel housing w/window, TO thermocouple output, XW= explosion proof window cover; other allowed markings but not relevant to certification; CA, CB, CE, CO, EN, SH, SHF, SPL, TC, TEE, TG and VI).

Zeros in the part number are just place holders with no options available 

Notes:

1.      If the process fluid temperature exceeds 40 ?C, the device can not be used in a process atmosphere that has an ignition temperature of 120 ?C increased by the difference of the fluid temperature and 40?C.

 

/rg