MANUFACTURED WIRING SYSTEMS - Manufactured wiring systems for dry non-hazardous locations
091749_0_000

TO THE REQUIREMENTS OF CSA STD 203.1:

Manufactured Wiring Systems:

Part A:

"100 Series" 

  • rated 20A, 125V ac; consisting of Cat Nos. 101125SCSccllld, 102125JCSccllld, 102125JCSTccllld, 103125SWIcc, 104125SWCSccllld, 105125BPcc, 107125TAPcc, 109125TAPccllld, 100125Flcc, 100125PTRTcc, 100125RTRTcc, 100125RRcc, 10031RTRTcc, 10041RTRTcc, 10031RRcc, 10041RRcc 
  • rated 20A, 277V ac or 347V ac; consisting of Cat Nos. 101347SCSccllld, 102347JCSccllld, 102347JCSTccllld, 103347SWIcc, 104347SWCSccllld, 105347BP, 107347TAPcc, 100347Flcc, 100347PTRTcc, 100347RTRTcc, 100347RRcc 
  • rated 20A, 125V ac; consisting of Cat Nos. 11031MTccllld, 11141MTccllld 
  • rated 20A, 125/250V ac; consisting of Cat Nos. 11242MTccllld , 10042RTRTcc, 10042RRcc.

"w2" Series 

  • rated 20A, 125/250V ac; consisting of Cat Nos. w2FTccllld, w2MFccllld, w2MTccllld, w2Pcc, w2Rcc

"w4" Series 

  • rated 20A, 125/250V ac; consisting of Cat Nos. w4FTccllld, w4MFccllld, w4MTccllld, w4Pcc, w4Rcc

"w6" Series

  • rated 20A, 125/250V ac; consisting of Cat Nos. w6FTccllld, w6MFccllld, w6MTccllld, w6STccllld, w6TAPcc, w6Rcc, w6Scc, w6Pcc

"w7" Series 

  • rated 20A, 277/480V ac or 347/600V ac; consisting of Cat Nos. w7FTccllld, w7MFccllld, w7MTccllld, w7Rcc, w7Pcc

Part B: 

  • Enclosures for interconnection of wiring systems: Types "Bxxyyzz" and "Exxyyzz" (where xx, yy and zz are replaced by suffix numbers).

Part C: 

  • "ULTRALX", interconnecting electrical accessory: Types "Utnnggffllld" and "Utnnggffnnggffllld", rated at 20A, 600V ac (consisting of one or two Certified armoured cable fittings on opposite ends of armoured cable).

Notes: 

  1. Installation in  accordance with the Canadian Electrical Code, Part I.
  2. Mating connectors rated 480V ac and 600V ac are not for interrupting current.
  3. The following catalogue numbers are suitable for ballast disconnect in Fluorescent Luminaires: (rated 125V 20A) 100125FIcc, 100125PTRTcc, 100125RTRTcc, 100125RRcc; (rated 277V, 347V 20A) 100347FIcc, 100347PTRTcc, 100347RTRTcc, 100347RRcc; (rated 125/250V 20A) w6Pcc, w6Rcc.
  • Manufactured Wiring System, ?EZ-Wiring? D-Series?, 3-wire (single circuit) and 4-wire (two circuit) systems, with electrical ratings and electrical accessory catalogue designations as noted below:

a)      rated 15A, 125/250V ac; consisting of Cat Nos. sD-21wxyz-flllduuab
b)      rated 20A, 125/250V ac; consisting of Cat Nos. sD-22wxyz-flllduuab
c)      rated 20A, 277/480V ac; consisting of Cat Nos. sD-42wxyz-flllduuab
d)      rated 20A, 347/600V ac; consisting of Cat Nos. sD-62wxyz-flllduuab

where,        s = construction standard (1 = Dual-listed (CEC & NEC) construction with AC90/MC Cable, 2 = CEC construction, with AC90 Cable)
                  
w = number of lines (1 or 2)
                   x = number of neutrals (1 or 0)
                   y = number of grounds (1 or 2)
                   z = number of switch legs/returns/others (0, 1 or 2)
                   f = function (C = Starter Cable, D = Drop Cable, E = Extender Cable, F = Fixture Tap)
                   lll (Cables only) = cable length in dm (ie: 040 = 4.0m)
                   d (Cables only) = cable type designation (ie: A = Armoured cable)
                   uu (Cables only) = wire upsize factor (ie: 10 = upsized Neutral, 11 = upsized all, Blank = no upsizing)
                   a (Fixture Tap only) = wire upsize factor (ie: 1 = 16AWG, 2 = 14AWG, 3 =12AWG)
                   b (Fixture Tap only) = push-in connector option (ie: 1 = installed, Blank = none)

e)      Enclosures for interconnection of electrical accessories: Types ?sD-Bxxyyzz? (where xx, yy and zz are replaced by suffix numbers denoting box size and type) followed by ?vcwxyz-fllld?:

where:        s = construction standard (2 = CEC construction, with AC90 Cable)
                   v = voltage (2 = 125/250V ac, 4 = 277/480V ac, 6 = 347/600V ac)
                   c = current (1 = 15A, 2 = 20A)
                   w = number of lines
                   x = number of neutrals
                   y = number of grounds
                   z = number of switch legs/returns/others
                   f = function (C = Starter Cable, T = Tap, S = Switch Tap)
                   lll (Cables only) = cable length in dm (040 = 4.0m)
                   d (Cables only) = cable type designation (A = armoured cable)
                   uu (Cables only) = wire upsize factor (10 = upsized Neutral, 11 = upsized all, Blank = no upsizing)

Notes:

  1. Installation is in accordance with Canadian Electrical Code, Part I.
  2. Acceptable means for Ballast Disconnect Means for Fluorescent Luminaires.
  3. Manufactured Wiring System electrical accessory special-use connectors are suitable for interrupting current.
  4. Manufactured Wiring System electrical accessories rated above 347V ac have special-use connectors which are ?NOT FOR INTERRUPTING CURRENT?.
  • Manufactured Wiring System, ?EZ-Wiring? H-Series?, with electrical ratings and electrical accessory catalogue designations as noted below: 
a)      rated 20A, 125/250Vac; consisting of Cat No SH-2C-LNGO-FlllDWttXYZ
b)      rated 20A, 277/480Vac*; consisting of Cat No SH-4C-LNGO-FlllDWttXYZ
c)      rated 20A, 347/600Vac*; consisting of Cat No SH-6C-LNGO-FlllDWttXYZ

*Electrical Accessories rated above 347Vac are eligible to bear the CSA Mark only (class 6242 05).

where,           S = construction standard (1=Dual-listed (CEC & NEC) construction with AC90/MC Cable ,
2=CEC construction with AC90 Cable)
C = current system (2=20A, D=20A DALI/Controls)
L = number of lines (1, 2, 3 or 4)
N = number of neutrals (0, 1, 2 or 3)
G = number of grounds (1 or 2)
O = number of switch legs/returns/low-voltage control circuits (0, 1 or 2)
F = function (C=Starter Cable, D=Drop Cable, E=Extender Cable, F=Fixture Tap, P=Plug, R=Receptacle, W=Fixture Whip)
lll = (Cables only) cable length in dm (ie: 040=4.0m)
D = (Cables only) cable type designation (ie: A=armoured cable)
W = (Cables, Plugs and Receptacles only) wire upsize factor (N=upsized Neutral,
Blank=None, 0=#10AWG, 2=#12AWG), (Fixture Tap , Fixture Whip) wire gauge 4=#14AWG, 6=#16AWG, 8=#18AWG,
tt = Tail Length in cm (ie: 20=20cm)
XYZ = Options (Fixture Tap & Fixture Whip only) push-in connector option (ie: TXP=installed, Blank=none)

d)      Enclosures for interconnection of electrical accessories: Types ?sH-vc-wxyz-Bxxyyzz? and ?Exxyyzz? (where xx, yy, and zz are replaced by suffix numbers denoting box size and type) followed by ?flllduu?.

where:       s = construction standard (2 = CEC construction, with AC90 Cable)
                 
v = voltage (2 = 125/250V ac, 4 = 277/480V ac*, 6 = 347/600V ac*)
                 
c = current (1 = 15A, 2 = 20A)
                 
w = number of lines
                 
x = number of neutrals
                 
y = number of grounds
                 
z = number of switch legs/returns/others
                 
f = function (C = Starter Cable, T = Tap, S = Switch Tap)
                 
lll (Cables only) = cable length in dm (040 = 4.0m)
                 
d (Cables only) = cable type designation (A = armoured cable)
                 
uu (Cables only) = wire upsize factor (10 = upsized Neutral, 11 = upsized all,
                 
Blank= no upsizing)

e)     Power Strip for use with manufactured wiring system ?EZ-Wiring H ? Series?, up to 8 wire components, rated 20 A max, 125/250 V. Consisting of Cat. Nos. tH-vc-lngo-PS-xyzllla

Where:        t = standard (1 = UL/CSA (MC/AC-90 cable), 2 = CSA (AC-90 cable)
                    vc = system (22 = 125/250V,  20 A, 21 = 125/250V, 15 A)
                    lngo = application  (power distribution up to 8w max)
                                l = number of lines (1 to 4)
                                n = number of neutrals (1 to 3)
                                g = number of grounds  (1 to 2)
                    x = switching option (0 = unswitched, 1 = switch per circuit, 2 = illuminated switch per circuit)
                    y = # 5-20R/CCT (1, 2 or 3)
                    z = end receptacle option (0 = none, 1 = EZ-Wiring receptacle included)
                    lll = cable length in dm (040 = 4.0m)
                    a = cable type designation (A = standard armoured cable, H = halogen free armoured cable)

Notes:

  1. Installation in accordance with the Canadian Electrical, Part I (CEC Part I).

  2. Acceptable means for Ballast Disconnect Means for Fluorescent Luminaires.

  3. Manufactured Wiring System electrical accessory special-use connectors are suitable for interrupting current.

  4. Manufactured Wiring System electrical accessories rated above 347V ac have special-use connectors which are ?NOT FOR INTERRUPTING CURRENT?.