Codes & Standards - Purchase
ISO 3856-7:1984
Paints and varnishes -- Determination of "soluble" metal content -- Part 7: Determination of mercury content of the pigment portion of the paint and of the liquid portion of water-dilutable paints -- Flameless atomic absorption spectrometric method
SKU: iso_009433_103344
Published by ISO
Publication Year 1984
1 Edition
8 pages
Product Details
The principle consists in oxidation of the of hte mercury compounds contained in the test solution obtained from the pigment portion of the paint or combustion with oxygen in an enclosed system of the evaporation residue of the test solution obtained from the liquid portion of water-dilutable paints. Reduction of the mercury(II) compounds to elementary mercury. Determination of the mercury, as the monoatomic vapour, by cold vapour (flameless) atomic absorption spectrometry at a wavelength in the region of 253,7 nm. The method is applicable to coating materials having soluble mercury contents in the range of about 0,005 % (m/m) to 0,05 % (m/m).