IEC 60335-2-60:2023
Household and similar electrical appliances - Safety - Part 2-60: Particular requirements for whirlpool baths and whirlpool spas
Product Details
- persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
- children playing with the appliance.
Attention is drawn to the fact that
- for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
- in many countries additional requirements are specified by the national health authorities, the national water supply authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to
- equipment for water circulation in swimming and motion exercise pools;
- cleaning appliances for swimming pools;
- appliances intended for medical purposes (IEC 60601 series);
- field-engineered, non-self-contained permanently installed whirlpool baths or whirlpool spas custom designed to fit a specific location, being assembled or constructed at the final installation location;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
This fifth edition cancels and replaces the fourth edition published in 2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with IEC 60335-1:2020;
b) conversion of some notes to normative text (Clause 1, 7.12.1);
c) addition of hyperthermia instructions and installation instructions related to the wiring rules (7.12, 7.12.1);
d) modifications related to IEC 60364-7-702 and transportable whirlpool spas (Clause 1, 5.101, 6.1, 6.2, 7.12.1, 7.15, 13.1, 13.2, 16.1, 16.2, 22.33, 22.107, 25.1);
e) introduction of surface temperature limits (Clause 11);
f) addition of water temperature limit at the suction/return openings (11.8, 11.101);
g) modification to the tests of 19.2 and 19.3 specifying the types of devices that are rendered inoperative.
h) addition of requirement for thermal cut-outs to be trip free (24.101).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.