Cookies on CSA Group

We use Cookies to create a secure and effective website experience for our customers. For more information about Cookies and how you can disable Cookies, visit our privacy policy page. Learn More

logo close
Privacy Preference Centre

Please manage your cookie choices by switching the consent toggles on or off under the Purposes below.

You may change your preference at any time as described in our Cookie Policy

  • Cookie Settings
  • List of Cookies
close
    Skip to content
    CSA Store
    • CSA Group
    • CSA OnDemand™
    • CSA Communities
    • Contact Us
    • Catalogue
      • Browse By Subject Area

        • Electrical
        • Fuels & Transportation
        • Petroleum & Natural Gas
        • Environment & Natural Resources
        • Construction & Infrastructure
        • Mechanical & Industrial Equipment
        • Nuclear
        • Health Care and Well-being
        • Worker & Public Safety
        • Management Systems
      • Browse By Publisher

        • ASME
        • ASTM
        • CSA Group
        • ESA
        • IEC
        • ISO
        • NRC
        • ORNAC
        • TSSA
      • ICS Catalogue

        • Browse by International Classification of Standards (ICS Codes)
    • Subscription
      • Browse By Subject Area

        • Electrical
        • Fuels & Transportation
        • Petroleum & Natural Gas
        • Environment & Natural Resources
        • Construction & Infrastructure
        • Mechanical & Industrial Equipment
        • Nuclear
        • Health Care and Well-being
        • Worker & Public Safety
        • Management Systems
      • CSA Subscriptions

        • Why choose subscriptions?
        • About CSA Advantage™
        • About CSA OnDemand™
        • CSA OnDemand™ Collections
      • ICS Catalogue

        • Browse by International Classification of Standards (ICS Codes)
    • Services
    Cart Icon0
    ×
    Login / Register
    English / CAD

    Language

    en

    fr

    Currency

    CAD

    USD

    • CSA Group
    • CSA OnDemand™
    • CSA Communities
    • Contact Us
    Wishlist

    Catalogue

    • Browse By Subject Area

      • Electrical
      • Fuels & Transportation
      • Petroleum & Natural Gas
      • Environment & Natural Resources
      • Construction & Infrastructure
      • Mechanical & Industrial Equipment
      • Nuclear
      • Health Care and Well-being
      • Worker & Public Safety
      • Management Systems
    • Browse By Publisher

      • ASME
      • ASTM
      • CSA Group
      • ESA
      • IEC
      • ISO
      • NRC
      • ORNAC
      • TSSA
    • ICS Catalogue

      • Browse by International Classification of Standards (ICS Codes)

    Subscription

    • Browse By Subject Area

      • Electrical
      • Fuels & Transportation
      • Petroleum & Natural Gas
      • Environment & Natural Resources
      • Construction & Infrastructure
      • Mechanical & Industrial Equipment
      • Nuclear
      • Health Care and Well-being
      • Worker & Public Safety
      • Management Systems
    • CSA Subscriptions

      • Why choose subscriptions?
      • About CSA Advantage™
      • About CSA OnDemand™
      • CSA OnDemand™ Collections
    • ICS Catalogue

      • Browse by International Classification of Standards (ICS Codes)

    Services

    Menu toggle Icon
    Login / Register
    English / CAD

    Language

    en

    fr

    Currency

    CAD

    USD

    Wishlist Cart (
    )

    Search Section

      • Home
      • CSA Group
      • Electrical
      • Electrical Equipment Safety Standards
      • Industrial Products (Hazloc, Energy and Power Equipment and Machinery) - Canadia
      • CSA C22.2 NO. 60947-4-1:22

      Codes & Standards - Purchase

      CSA C22.2 NO. 60947-4-1:22

      Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters (Binational standard with UL 60947-4-1)

      SKU: 2428428_2428459 Published by CSA Group Publication Year 2022 198 pages

      Product Details

      • Preface/Scope
      • Editions

      Preface


      This is the harmonized CSA Group and UL standard for Low-voltage switchgear and controlgear – Part 4-1: Contactors and motor-starters – Electromechanical contactors and motor-starters. It is the third edition of CSA C22.2 No. 60947-4-1, and the fourth edition of UL 60947-4-1. This edition of CSA C22.2 No. 60947-4-1 supersedes the previous edition published in 2014 as CAN/CSA-C22.2 No. 60947-4-1.


      This harmonized standard is based on IEC publication 60947-4-1, Edition 3.1, Low-voltage switchgear and controlgear – Part 4-1: Contactors and motor-starters – Electromechanical contactors and motor-starters, issued July 2012. IEC 60947-4-1 is copyrighted by the IEC.


      This harmonized standard was prepared by CSA Group and Underwriters Laboratories Inc. (UL). The efforts and support of the Technical Harmonization Committee for Industrial Control Equipment, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged.


      This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.


      This Standard was reviewed by the CSA Integrated Committee on Industrial Control, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee.


      This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group.


      Scope and object


      1.1 Scope


      This part of IEC 60947 applies to the types of equipment listed in 1.1.1 and 1.1.2 whose main contacts are intended to be connected to circuits the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.


      Starters and/or contactors dealt with in this standard are not normally designed to interrupt short-circuit currents. Therefore, suitable short-circuit protection (see 9.3.4) forms part of the installation but not necessarily of the contactor or the starter.


      In this context, this standard gives requirements for:


      – contactors associated with overload and/or short-circuit protective devices;


      – starters associated with separate short-circuit protective devices and/or with separate short-circuit and integrated overload protective devices;


      – contactors or starters combined, under specified conditions, with their own short-circuit protective devices. Such combinations, e.g. combination starters or protected starters are rated as units.


      For circuit-breakers and fuse-combination units used as short-circuit protective devices in combination starters and in protected starters, the requirements of IEC 60947-2 and IEC 60947-3 respectively apply.


      Equipment covered by this standard is as follows.


      1.1DV.1 D2 Modification of 1.1 by adding the following:


      This equipment is intended for installation in accordance with CSA C22.1, Canadian Electrical Code (CE Code, Part I), and the US National Electrical Code (NEC), NFPA 70.


      1.1.1 AC and DC contactors


      AC and DC contactors intended for closing and opening electric circuits and, if combined with suitable relays (see 1.1.2), for protecting these circuits against operating overloads which may occur therein.


      NOTE For contactors combined with suitable relays and which are intended to provide short-circuit protection, the relevant conditions specified for circuit-breakers (IEC 60947-2) additionally apply.


      This standard applies also to the actuators of contactor relays and to the contacts dedicated exclusively to the coil circuit of a contactor.


      Contactors or starters with an electronically controlled electromagnet are also covered by this standard.


      1.1.1DV.1 D2 Modification of 1.1.1 by adding the following:


      This standard also applies to manual controllers and combination motor controllers. See Annex DVC for specific requirements.


      1.1.2 AC motor-starters


      AC motor-starters (including motor management starter) intended to start and accelerate motors to normal speed, to ensure continuous operation of motors, to switch off the supply from the motor and to provide means for the protection of motors and associated circuits against operating overloads.


      For overload relays for starters, including those based on electronic technology with or without extended functions according to Annex H, the requirements of this standard apply.


      1.1.2.1 Direct-on-line (full voltage) a.c. starters


      Direct-on-line starters intended to start and accelerate a motor to normal speed, to provide means for the protection of the motor and its associated circuits against operating overloads, and to switch off the supply from the motor.


      This standard applies also to reversing starters.


      1.1.2.2 Reduced voltage a.c. starters


      Reduced voltage a.c. starters intended to start and accelerate a motor to normal speed by connecting the line voltage across the motor terminals in more than one step or by gradually increasing the voltage applied to the terminals, to provide means for the protection of the motor and its associated circuits against operating overloads, and to switch off the supply from the motor.


      Automatic change-over devices may be used to control the successive switching operations from one step to the others. Such automatic change-over devices are, for example, time-delay contactor relays or specified time all-or-nothing relays, under-current devices and automatic acceleration control devices (see 5.10).


      1.1.2.2.1 Star-delta starters


      Star-delta starters intended to start a three-phase motor in the star connection, to ensure continuous operation in the delta connection, to provide means for the protection of the motor and its associated circuits against operating overloads, and to switch off the supply from the motor.


      The star-delta starters dealt with in this standard are not intended for reversing motors rapidly and, therefore, utilization category AC-4 does not apply.


      NOTE In the star connection, the starting current in the line and the torque of the motor are about one-third of the corresponding values for delta connection. Therefore, star-delta starters are used when the inrush current due to the starting is to be limited, or when the driven machine requires a limited torque for starting. Figure 1 indicates typical curves of starting current, of starting torque of the motor and of torque of the driven machine.


      1.1.2.2.2 Two-step auto-transformer starters


      Two-step auto-transformer starters, intended to start and accelerate an a.c. induction motor from rest with reduced torque to normal speed and to provide means for the protection of the motor and its associated circuits against operating overloads, and to switch off the supply from the motor.


      This standard applies to auto-transformers which are part of the starter or which constitute a unit specially designed to be associated with the starter.


      Auto-transformer starters with more than two steps are not covered by this standard.


      The auto-transformer starters dealt with in this standard are not intended for inching duty or reversing motors rapidly and, therefore, utilization category AC-4 does not apply.


      NOTE In the starting position, the current in the line and the torque of the motor related to the motor starting with rated voltage are reduced approximately as the square of the ratio (starting voltage):(rated voltage). Therefore, auto-transformer starters are used when the inrush current due to the starting is to be limited or when the driven machine requires a limited torque for starting. Figure 2 indicates typical curves of starting current, of starting torque of the motor and of torque of the driven machine.


      1.1.2.3 Rheostatic rotor starters


      Starters intended to start an a.c. induction motor having a wound rotor by cutting out resistors previously inserted in the rotor circuit, to provide means for the protection of the motor against operating overloads and to switch off the supply from the motor.


      This standard applies also to starters for two directions of rotation when reversal of connections is made with the motor stopped (see 5.3.5.5). Operations including inching and plugging necessitate additional requirements and are subject to agreement between manufacturer and user.


      This standard applies to resistors which are part of the starter or constitute a unit specially designed to be associated with the starter.

      1.2 Exclusions


      This standard does not apply to:


      – d.c. starters;


      – star-delta starters, rheostatic rotor starters, two-step auto-transformer starters intended for special applications and designed for continuous operation in the starting position;


      – unbalanced rheostatic rotor starters, i.e. where the resistances do not have the same value in all phases;


      – equipment designed not only for starting, but also for adjustment of speed;


      – liquid starters and those of the liquid-vapour type;


      – semiconductor contactors and starters making use of semiconductor contactors in the main circuit;


      – rheostatic stator starters;


      – contactors or starters designed for special applications;


      – auxiliary contacts of contactors and contacts of contactor relays. These are dealt with in IEC 60947-5-1.


      1.3 Object


      The object of this standard is to state:


      a) the characteristics of contactors and starters and associated equipment;


      b) the conditions applicable to contactors and starters with reference to:


      1) their operation and behaviour,


      2) their dielectric properties,


      3) the degrees of protection provided by their enclosures, where applicable,


      4) their construction;


      c) the tests intended for confirming that these conditions have been met, and the methods to be adopted for these tests;


      d) the information to be given with the equipment or in the manufacturer's literature.

      items 1 - of 2 result(s)
      View 20 | View 100

      CSA C22.2 NO. 60947-4-1:14 (R2019)

      Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters (Bi-national standard, with UL 60947-4-1)

      Withdrawn
      EnglishFrench

      CAN/CSA-C22.2 NO. 60947-4-1-07 (R2012)

      CAN/CSA-C22.2 NO. 60947-4-1-07 (R2012) - Low-Voltage Switchgear and Controlgear - Part 4-1: Contactors and Motor-Starters - Electromechanical Contactors and Motor-Starters (Tri-National standard, with UL 60947-1A and NMX-J-290-ANCE)

      Withdrawn
      copyright imgRequest Copyright Permissions

      Buy

      Language

      Radio input

      Format

      Radio input
      • Free updates to the latest version
      • Access historical versions
      • Access all supported languages
      Learn More
      • FAQs
      • Contact Us
      • Email Product

      GST REG No R119441681
      QST REG No R1006017360

      Compare Formats

      Determine the subscription format that is right for you.

      Select the subscription format that is right for you. Table with 13 rows and 3 columns, identifies features available and not available for the two different subscription formats - CSA Advantage TM and CSA OnDemand TM
      Features CSA AdvantageTM CSA OnDemandTM
      Offline access CSA AdvantageTM. feature available. Offline access CSA OnDemandTM. feature available. Offline access
      Full-text search CSA AdvantageTM. feature available. Full-text search CSA OnDemandTM. feature available. Full-text search
      Create highlights and personal notes CSA AdvantageTM. feature available. Create highlights and personal notes CSA OnDemandTM. feature available. Create highlights and personal notes
      Newest editions added automatically CSA AdvantageTM. feature available. Newest editions added automatically CSA OnDemandTM. feature available. Newest editions added automatically
      Includes all supported languages and archive versions CSA AdvantageTM. feature not available. Includes all supported languages and archive versions CSA OnDemandTM. feature available. Includes all supported languages and archive versions
      My Files - create customized files by adding multiple clauses, tables or figures from the standard into your own personal File for quick reference CSA AdvantageTM. feature available. My Files - create customized files by adding multiple clauses, tables or figures from the standard into your own personal File for quick reference CSA OnDemandTM. feature not available. My Files - create customized files by adding multiple clauses, tables or figures from the standard into your own personal File for quick reference
      Toggle between your files and the full standard to maintain context CSA AdvantageTM. feature available. Toggle between your files and the full standard to maintain context CSA OnDemandTM. feature not available. Toggle between your files and the full standard to maintain context
      Instantly preview cross referenced material within the book CSA AdvantageTM. feature available. Instantly preview cross referenced material within the book CSA OnDemandTM. feature not available. Instantly preview cross referenced material within the book
      Export personal notes to Excel CSA AdvantageTM. feature available. Export personal notes to Excel CSA OnDemandTM. feature not available. Export personal notes to Excel
      Transfer notes and highlights when updates are available CSA AdvantageTM. feature available. Transfer notes and highlights when updates are available CSA OnDemandTM. feature not available. Transfer notes and highlights when updates are available
      Adobe Reader PDF and browser compatible for iOS and Android CSA AdvantageTM. feature not available. Adobe Reader PDF and browser compatible for iOS and Android CSA OnDemandTM. feature available. Adobe Reader PDF and browser compatible for iOS and Android
      Web, Android, iOS Compatible CSA AdvantageTM. feature available. Web, Android, iOS Compatible CSA OnDemandTM. feature not available. Web, Android, iOS Compatible

      Follow Us On Social Media

      Get Our Newsletter

      Get CSA Newsletter

      • About CSA Store
      • Subscription
      • Services
      • Catalogue
      • FAQ
      • Return Policy
      • FULFILLMENT DETAILS
      • EBOOK SUPPORT
      • Product Updates
      • Contact Us
      • CSA GROUP
      • CSA COMMUNITIES
      • CSA Update Service
      • About CSA Store
      • Subscription
      • Services
      • Catalogue
      • FAQ
      • Return Policy
      • FULFILLMENT DETAILS
      • EBOOK SUPPORT
      • Product Updates
      • Contact Us
      • CSA GROUP
      • CSA COMMUNITIES
      • CSA Update Service

      • General Terms and Conditions
      • Privacy Policy
      • Accessibility
      © 2023 Canadian Standards Association. All rights reserved

      Free Login/Registration Required

      View Access for this document is only available for viewers in Canada.

      A free user account is required to view this document.

      Login or Register