Codes & Standards - Purchase
CAN/CSA-E730-2-7-94 (R2013)
Automatic Electrical Controls for Household and Similar Use - Part 2: Particular Requirements for Timers and Time Switches (Adopted IEC 730-2-7:1990, first edition) | Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 2: Règles particulières pour les minuteries et les minuteries cycliques (norme CEI 730-2-7:1990 adoptée, première édition)
SKU: 2410069
Published by CSA Group
Publication Year 1994
Reaffirmed in 2013
59 pages
Withdrawn
Product Details
Scope
This clause of Part 1 is replaced as follows:
1.1
In general, this standard applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications.
Throughout this standard the word timers means timers and time switches, unless the type is specifically mentioned.
Devices which only indicate time or passage of time are not included.
This Standard does not apply to multi-functional controls having an integrated timing function which is not capable of being tested as a separate timing device.
This Standard does not apply to time-delay switches (T.D.S.) within the scope of IEC 669-2-3.
1.1.1
This Standard applies to the inherent safety, to the operating values, operating sequences where such are associated with equipment protection, and to the testing of timers used in, on or in association with household and similar equipment.
This Standard is also applicable to timers for appliances within the scope of IEC 335.
1.1.2
This Standard applies to manual controls when such are electrically and/or mechanically integral with timers.
Manual switches not forming part of an automatic control shall comply with IEC 328.
1.2
This Standard applies to controls with a rated voltage not exceeding 660 V and a rated current not exceeding 63 A.
1.3
This Standard does not take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. If a response value is of significant purpose for the safety of the user or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer shall apply.
1.4
Requirements for electronics contained in Appendix H are under consideration.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Domaine d’application
L'article de la première partie est remplacé par:
1.1
D'une manière générale, la présente norme s'applique aux minuteries et aux minuteries cycliques à usage domestique et analogue qui peuvent utiliser l'électricité, le gaz, le pétrole, un combustible solide, l'énergie thermique solaire, etc., ou une combinaison de ces énergies, y compris des applications de chauffage, climatisation et usages analogues.
Partout où il est utilisé dans la présente norme le terme minuterie signifie minuterie et minuterie cyclique, sauf si le type de dispositif est clairement précisé.
Les dispositifs qui n'indiquent que le temps ou son écoulement n'entrent pas dans le domaine d'application de la présente norme.
La présente norme ne s'applique pas aux dispositifs de commande multi-fonctions qui ont une fonction de minuterie intégrée qui ne peut être essayée comme un composant de petites dimensions séparé.
La présente norme ne s'applique pas aux interrupteurs temporisés (appelés également minuteries) entrant dans le domaine d'application de la CEI 669-2-3.
1.1.1
La présente norme s'applique à la sécurité intrinsèque, aux valeurs et aux séquences de fonctionnement dans la mesure où elles interviennent dans la protection des matériels ainsi qu'a ux essais des minuteries utilisées dans ou avec du matériel à usage domestique et analogue.
La présente norme s'applique également aux minuteries pour les appareils entrant dans le domaine d'application de la CEI 335.
1.1.2
La présente norme s'applique aux dispositifs de commande manuelle s'ils sont intégrés électriquement et/ou mécaniquement aux minuteries.
Les interrupteurs manuels ne faisant pas partie d'un dispositif de commande automatique doivent être conformes à la CEI 328.
1.2
La présente norme s'applique aux dispositifs de commande dont la tension nominale ne dépasse pas 660 V et le courant nominal 63 A.
1.3
La présente norme ne prend pas en compte la valeur de réponse d'une action automatique d'un dispositif de commande lorsqu'elle est influencée par la méthode de montage du dispositif de commande dans le matériel. Dans le cas où une telle valeur de réponse est importante du point de vue de la sécurité de l'utilisateur ou de l'environnement, la valeur définie dans la norme appropriée du matériel domestique concerné ou déterminée par le fabricant doit s'appliquer.
1.4
Des prescriptions applicables aux composants électroniques figurant dans l'annexe H sont à l'étude.
This clause of Part 1 is replaced as follows:
1.1
In general, this standard applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications.
Throughout this standard the word timers means timers and time switches, unless the type is specifically mentioned.
Devices which only indicate time or passage of time are not included.
This Standard does not apply to multi-functional controls having an integrated timing function which is not capable of being tested as a separate timing device.
This Standard does not apply to time-delay switches (T.D.S.) within the scope of IEC 669-2-3.
1.1.1
This Standard applies to the inherent safety, to the operating values, operating sequences where such are associated with equipment protection, and to the testing of timers used in, on or in association with household and similar equipment.
This Standard is also applicable to timers for appliances within the scope of IEC 335.
1.1.2
This Standard applies to manual controls when such are electrically and/or mechanically integral with timers.
Manual switches not forming part of an automatic control shall comply with IEC 328.
1.2
This Standard applies to controls with a rated voltage not exceeding 660 V and a rated current not exceeding 63 A.
1.3
This Standard does not take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. If a response value is of significant purpose for the safety of the user or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer shall apply.
1.4
Requirements for electronics contained in Appendix H are under consideration.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Domaine d’application
L'article de la première partie est remplacé par:
1.1
D'une manière générale, la présente norme s'applique aux minuteries et aux minuteries cycliques à usage domestique et analogue qui peuvent utiliser l'électricité, le gaz, le pétrole, un combustible solide, l'énergie thermique solaire, etc., ou une combinaison de ces énergies, y compris des applications de chauffage, climatisation et usages analogues.
Partout où il est utilisé dans la présente norme le terme minuterie signifie minuterie et minuterie cyclique, sauf si le type de dispositif est clairement précisé.
Les dispositifs qui n'indiquent que le temps ou son écoulement n'entrent pas dans le domaine d'application de la présente norme.
La présente norme ne s'applique pas aux dispositifs de commande multi-fonctions qui ont une fonction de minuterie intégrée qui ne peut être essayée comme un composant de petites dimensions séparé.
La présente norme ne s'applique pas aux interrupteurs temporisés (appelés également minuteries) entrant dans le domaine d'application de la CEI 669-2-3.
1.1.1
La présente norme s'applique à la sécurité intrinsèque, aux valeurs et aux séquences de fonctionnement dans la mesure où elles interviennent dans la protection des matériels ainsi qu'a ux essais des minuteries utilisées dans ou avec du matériel à usage domestique et analogue.
La présente norme s'applique également aux minuteries pour les appareils entrant dans le domaine d'application de la CEI 335.
1.1.2
La présente norme s'applique aux dispositifs de commande manuelle s'ils sont intégrés électriquement et/ou mécaniquement aux minuteries.
Les interrupteurs manuels ne faisant pas partie d'un dispositif de commande automatique doivent être conformes à la CEI 328.
1.2
La présente norme s'applique aux dispositifs de commande dont la tension nominale ne dépasse pas 660 V et le courant nominal 63 A.
1.3
La présente norme ne prend pas en compte la valeur de réponse d'une action automatique d'un dispositif de commande lorsqu'elle est influencée par la méthode de montage du dispositif de commande dans le matériel. Dans le cas où une telle valeur de réponse est importante du point de vue de la sécurité de l'utilisateur ou de l'environnement, la valeur définie dans la norme appropriée du matériel domestique concerné ou déterminée par le fabricant doit s'appliquer.
1.4
Des prescriptions applicables aux composants électroniques figurant dans l'annexe H sont à l'étude.