Overview

ACL Manufacturing Inc. Announces Recall of Safety Valve Series ACL-SV-SSO-8-24

CSA-International has been advised of the following recall issued by ACL Manufacturing and this is being forwarded for your further information.

ACL Manufacturing Inc. is announcing the recall of a certain production run of their Series ACL-SV-SSO-8-24 valve to address the potential safety hazard where the valve may inadvertently remain open when it should close.

Investigation by ACL has determined that the actuator plunger component of the electric solenoid fails to operate reliably. ACL is not aware of any incidents of injury or property damage as a result of this potential safety hazard.

Approximately 161 units were produced between June 1, 2010 and October 26, 2010 and these will be repaired by replacing the plunger spring. All customers are being contacted directly by ACL who will make arrangements for their repair.

The recalled valves can be identified by the date code on their nameplate which is printed beneath the box identifying the model number as shown below. The recalled units are date coded from 6.1-2010 through 10.26-2010.

Safety Valve

Please contact ACL Manufacturing Inc. – Andrew Pearce or Chris Aldrich at (403) 638-5234 to arrange for the corrective action. Your immediate attention to this is required.

About CSA International

CSA International is a provider of product testing and certification services for electrical, mechanical, plumbing, gas and a variety of other products. Recognized in the U.S., Canada and around the world, CSA’s marks appear on billions of products worldwide. CSA International is a division of CSA Group, which also includes: CSA, a developer of standards and codes; and OnSpeX for consumer product evaluation services. CSA International can be found online at www.csa-international.org.

Contact

Anthony Toderian
Senior Media Relations Officer CSA Group
416-747-2620
[email protected]