MCERTS Certified Products: Continuous Emission Monitoring System

Overview

MCERTS Certified Products: Continuous Emission Monitoring System

MCERTS standards may not cover all possible stack conditions. Any potential user should ensure, in consultation with the manufacturer, that the CEMs is suitable for the process on which it will be installed. It is important to refer to the details on certificates issued as they may contain specific limitations on use. The certificate holders listed have submitted satisfactory test reports and successfully undergone a product manufacturing audit. Ranges can indicate the suitability of CEMs for a particular application. In general, CEMs with a lower certified range not only indicate suitability for applications with low emissions limit values, but typically perform at least as well for higher ranges too. Some manufacturers have had two ranges tested as further assurance of suitability for a wider spectrum of applications. If CEMs with higher monitoring ranges are to be used for applications with low emissions limit values, then the prospective user is advised to seek assurance that the systems also perform well at lower ranges.
Issue 488 updated 23/04/2024
table
Certificate holderModelCertified rangeStandardCertificate No.

ABB AG

Tel: +49 69 793040
UK Sales
Tel: +44 (0)1453 826661

AO2000 Series
Multigas Analysers
with SCC-K NO/NO2
converter

CO 0 to 75 mg/m3
0 to 4,000 mg/m3

NO 0 to 100 mg/m3
0 to 5,000 mg/m3

NOx 0 to 150 mg/m3
0 to 7,500 mg/m3

SO2 0 to 75 mg/m3
0 to 8,000 mg/m3

N2O 0 to 100 mg/m3
0 to 6,700 mg/m3

CO2 0 to 20 Vol.-%
O2 0 to 10 Vol.-%
0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
09/01/2023

ABB AG

Tel: +49 69 793040
UK Sales
Tel: +44 (0)1453 826661

EL3000 Series
Multigas Analysers
with SCC-K NO/NO2
converter

CO 0 to 150 mg/m3
0 to 4,000 mg/m3
NO 0 to 100 mg/m3
0 to 5,000 mg/m3
NOx 0 to 150 mg/m3
0 to 7,500 mg/m3
SO2 0 to 300 mg/m3
0 to 8,000 mg/m3
N2O 0 to 100 mg/m3
0 to 6,700 mg/m3
CO2 0 to 20 Vol.-%O2 0 to 10 Vol.-%
0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
09/01/2023

ABB AG

Tel: +49 697930 4666
UK Sales
Tel: +44 (0)1453 826661

ACF5000 measuring system

CO 0 to 75 mg/m3
0 to 300 mg/m3
0 to 4,000 mg/m3
NO 0 to 150 mg/m3
0 to 400 mg/m3
0 to 2,000 mg/m3
NO2 0 to 80 mg/m3
0 to 600 mg/m3
0 to 1,000 mg/m3
N2O 0 to 50 mg/m3
0 to 1,000 mg/m3
SO2 0 to 75 mg/m3
0 to 300 mg/m3
0 to 5,000 mg/m3
HCl 0 to 15 mg/m3
0 to 90 mg/m3
0 to 2,000 mg/m3
HF 0 to 3 mg/m3
0 to 6 mg/m3
0 to 300 mg/m3
NH3 0 to 5 mg/m3
0 to 15 mg/m3
0 to 230 mg/m3
H2O 0 to 40 Vol.-% CO2 0 to 30 Vol.-%H2CO 0 to 20 mg/m3CH4 0 to 7.5 mg/m3
0 to 200 mg/m3
Total C (FID) 0 to 15 mg/m3
0 to 30 mg/m3
0 to 300 mg/m3
0 to 500 mg/m3
O2 (ZrO2)0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
09/03/2023

ABB Automation
GmbH

Tel: +49 697930 4901
UK Sales
Tel: +44 (0)1453 826661

AO2000-Fidas24

TOC 0 to 15 mg/m3
0 to 50 mg/m3
0 to 150 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
23/12/2021

ABB Automation
GmbH

Tel: +49 697930 4901
UK Sales
Tel: +44 (0)1453 826661

AO2000-Limas21 UV

NO 0 to 25 mg/m3
0 to 200 mg/m3

NO2 0 to 50 mg/m3
0 to 500 mg/m3

SO2 0 to 75 mg/m3
0 to 300 mg/m3

O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
01/04/2021

ABB Automation
GmbH

Tel: +49 697930 4901
UK Sales
Tel: +44 (0)1453 826661

EL3000-Limas23

NO 0 to 33.5 mg/m3
0 to 200 mg/m3

NO2 0 to 125 mg/m3
0 to 500 mg/m3

SO2 0 to 75 mg/m3
0 to 300 mg/m3

O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
31/03/2021

ABB Automation
GmbH

Tel: +49 697930 4901
UK Sales
Tel: +44 (0)1453 826661

EL3000-Fidas24

TOC 0 to 15 mg/m3
0 to 50 mg/m3
0 to 150 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
23/12/2021

ABB Ltd

Tel. +44 (0)1453 826661

Endura AZ20 / AZ30
measuring system

O2 0 to 25 Vol.-%O2 0 to 5 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
19/11/2021

ABB Ltd

Tel. +44 (0)1453 826661

StackFlowMaster System

Velocity 2 to 25 m/s
2 to 35 m/s

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
EN 16911-2:2013
QAL1

Version issued:
24/03/2023

AMETEK Land

4650-PM

Particulate concentration
0 to 7.5 mg/m3
0 to 15 mg/m3
0 to 100 mg/m3
0 to 200 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/12/2020

AP2E 

Tel: +33 (0)4 42 61 29 40
Email: [email protected]

ProCeas LaserCEM

CO 0 to 75 mg/m3 NO 0 to 78 mg/m3
0 to 150 mg/m3
0 to 2008 mg/m3
NH30 to 15 mg/m3
0 to 45 mg/m3
0 to 76 mg/m3
H2O 0 to 30 Vol.-%
0 to 40 Vol.-%
O2 0 to 21 Vol.-%
SO2 0 to 75 mg/m3
0 to 2858 mg/m3
HCl 0 to 15 mg/m3
0 to 98 mg/m3

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
10/02/2019

Auburn Systems, LLC

Tel: (978) 777-2460.
Email: [email protected]

U3600-QAL1

Dust 0 to 1,000 pA
0 to 10,000 pA
0 to 100,000 pA

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
16/09/2022

Codel International Ltd

Tel: +44 1629 814351
Fax: +44 1629 814619

D-CEM2100 Dust Monitor

Dust 0 to 0.1 Ext.*
0 to 0.3 Ext.
0 to 1.0 Ext

(*0 to 0.1 Ext. ≡ 0 to15
mg/m3 dust at 5m optical
path length)

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN15267
QAL 1

Version issued:
09/11/2020

Codel International Ltd

Tel: +44 1629 814351
Fax: +44 1629 814619

V-CEM5100 Flow
Monitor

Velocity 3 to 50 m/s

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN15267
QAL 1

Version issued:
09/11/2020

Codel International Ltd

Tel: +44 1629 814351
Fax: +44 1629 814619

Codel GCEM 40

CO 0 to 500ppm
0 to 1,000ppm

NO 0 to 500ppm
0 to 1,000ppm

SO2 0 to 500ppm
0 to 1,000ppm

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
11/08/2021

Dr. Födisch
Umweltmesstechnik AG

Tel: +49 34205 755-0
Fax: +49 34205 75540
Email: [email protected]

MCA 04 Multi
Component Analyser

CO 0 to 75 mg/m3
0 to 300 mg/m3
NO 0 to 200 mg/m3
0 to 395 mg/m3
SO2 0 to 75 mg/m3
0 to 300 mg/m3
HCl 0 to 15 mg/m3
0 to 90 mg/m3
NH3 0 to 30 mg/m3
0 to 75 mg/m3
NO2 0 to 50 mg/m3
0 to 1,000 mg/m3
N2O 0 to 50 mg/m3
0 to 1,000 mg/m3
H2O 0 to 40 Vol.-%CO2 0 to 20 Vol.-%O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
27/06/2022

Dr. Födisch
Umweltmesstechnik AG

Tel: +49 34205 755-0
Fax: +49 34205 75540
Email: [email protected]

MCA 10 Multi
Component Analyser

CO 0 to 75 mg/m3
0 to 300 mg/m3
0 to 5,000 mg/m3

NO 0 to 80 mg/m3
0 to 200 mg/m3
0 to 400 mg/m3
0 to 3,000 mg/m3

NO2 0 to 50 mg/m3
0 to 500 mg/m3
N2O 0 to 50 mg/m3
0 to 3,000 mg/m3
SO2 0 to 75 mg/m3
0 to 300 mg/m3
0 to 2,500 mg/m3
HCl 0 to 15 mg/m3
0 to 90 mg/m3
0 to 5,000 mg/m3
NH3 0 to 10 mg/m3
0 to 50 mg/m3
0 to 500 mg/m3
CH4 0 to 50 mg/m3
0 to 500 mg/m3
HF 0 to 20 mg/m3TOC 0 to 15 mg/m3
0 to 30 mg/m3
CO2 0 to 25 Vol.-%
0 to 50 Vol.-%
O2 0 to 25 Vol.-%H2O 0 to 40 Vol.-%

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
07/09/2020

Dr. Födisch
Umweltmesstechnik AG

Tel: +49 34205 755-0
Fax: +49 34205 75540
Email: [email protected]

FMD 09 Flow Monitor

Velocity 2 to 30 m/s
2 to 60 m/s

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
27/06/2022

Dr. Födisch
Umweltmesstechnik AG

Tel: +49 34205 755-0
Fax: +49 34205 75540
Email: [email protected]

MGA 12 HR

CO 0 to 125 mg/m3
0 to 1000 mg/m3
NO 0 to 300 mg/m3
0 to 1000 mg/m3
SO2 0 to 200 mg/m3
0 to 1000 mg/m3
O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
02/10/2023

Dr. Födisch
Umweltmesstechnik AG

Tel: +49 34205 755-0
Fax: +49 34205 75540
Email: [email protected]

PFM20

Dust
Certification range 0 to 7.5 mg/m3

Suppl. ranges 0 to 15 mg/m3
0 to 30 mg/m3
0 to 250 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/12/2022

DURAG GmbH

Tel: +49 (0)40554218-0

D-FL 100 Flow
Monitor

Velocity 3 to 30 m/s
3 to 50 m/s

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
28/09/2021

DURAG GmbH

Tel: +49 (0)40554218-0

HM 1400 TRX2
Mercury Analyser

Mercury 0 to 15 µg/m3
0 to 45 µg/m3
0 to 75 µg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
20/01/2022

DURAG GmbH

Tel: +49 (0)40554218-0

D-R 820F extractive
dust monitor

Particulate Concentration
0 to 15 mg/m3
0 to 100 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
16/09/2022

DURAG GmbH

Tel: +49 (0)40554218-0

D-FL 220 Flow
Monitor

Velocity 3 to 30 m/s

MCERTS
Performance
Standard V4
dated January
2018
EN15267
QAL 1

Version issued:
12/07/2019

DURAG GmbH

Tel: +49 (0)40554218-0

D-R 320 particulate
analyser

Dust 0 to 7.5 mg/m3
0 to 500 SL
0 to 1,000 SL
0 to 4,000 SL
0 to 20,000 SL
0 to 100 SL

MCERTS
Performance
Standard V4
dated July
2018

Version issued:
19/07/2019

DURAG GmbH

Tel: +49 (0)40554218-0

D-R 290 Opacity and
Dust Concentration
Monitor with
measuring head D-R
290 M EC2

Dust (optical transmission)
0 to 15 mg/m3 ≡ 0 – 0.1 Abs.

0 – 0.2 Abs.
0 – 0.5 Abs.
0 – 1.6 Abs.
0 – 100% Opacity

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL1

Version issued:
15/09/2020

DURAG GmbH

Tel: +49 (0)40554218-0

D-R 808 Dust
Monitor

Dust 0 to 7.5 mg/m3
0 to 500 SL
0 to 1,000 SL
0 to 4,000 SL
0 to 20,000 SL
0 to 100 SL

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
28/04/2022

Emerson Asia Pacific Private Limited

Tel: +65 65078650
Email: [email protected]

ASCO™ P150Q Continuous Particulate Emission Monitor

Dust 0 to 1,000 pA
0 to 10,000 pA
0 to 100,000 pA

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
23/12/2022

Emerson Process
Management Ltd

Email:
[email protected]

X- Stream enhanced

CO 0 to 75 mg/m3
0 to 3,000 mg/m3

NOx* 0 to 150 mg/m3
0 to 2,000 mg/m3

SO2 0 to 150 mg/m3
0 to 2,500 mg/m3

CO2 0 to 25 Vol.-%
O2 0 to 25 Vol.-%
(paramagnetic)
O2 0 to 25 Vol.-%
(electrochemical)

*expressed as NO, corresponds to 0-230 mg/m3 NOx as NO2

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
25/07/2023

ENOTEC GmbH

Tel: +49 (0) 4171 6672 70
www.enotec.de
UK Sales
Tel: +44 (844) 247 0102

OXITEC 5000+

O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
11/05/2022

Envea

Tel: +33 (0)1392 23800

CBISS Ltd (UK agent)
Tel: +44 (0)151 666 8300
Fax: +44(0)151 666 8329
www.cbiss.com

MIR9000 Multi-gas
Analyser Type 2 SEC
Probe & MIR9000 CLD option
Type 2 SEC Probe
MDS (Module Dryer
System)

SO2 0 to 75 mg/m3
SO2 0 to 200 mg/m3
CO 0 to 75 mg/m3
CO 0 to 500 mg/m3
CO2 0 to 25 Vol.-%
HCl 0 to 15 mg/m3
HCl 0 to 100 mg/m3
NO 0 to 100 mg/m3
NO 0 to 500 mg/m3
N2O 0 to 20 mg/m3
N2O 0 to 200 mg/m3
O2 0 to 10 Vol.-%
O2 0 to 25 Vol.-%
CH4 0 to 10 mg/m3
CH4 0 to 200 mg/m3

NO/NOx(CLD) 0 to 20 mg/m3
NO/NOx(CLD) 0 to 2,000mg/m3
NO2 (CLD) 0 to 20 mg/m3
NO2(CLD) 0 to 2,000 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
11/01/2022

Envea

Tel: +33 (0)1392 23800

CBISS Ltd (UK agent)
Tel: +44 (0)151 666 8300
Fax: +44(0)151 666 8329
www.cbiss.com

MIR-IS Multi-gas
analyser Type 2 SEC Probe

SO2 0 to 75 mg/m3
SO2 0 to 200 mg/m3
CO 0 to 75 mg/m3
CO 0 to 500 mg/m3
CO2 0 to 25 Vol.-%
HCl 0 to 15 mg/m3
HCl 0 to 100 mg/m3
NO 0 to 100 mg/m3
NO 0 to 500 mg/m3
N2O 0 to 20 mg/m3
N2O 0 to 200 mg/m3
O2 0 to 10 Vol.-%
O2 0 to 25 Vol.-%
CH4 0 to 10 mg/m3
CH4 0 to 200 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
13/02/2024

Envea

Tel: +33 (0)1392 23800

CBISS Ltd (UK agent)
Tel: +44 (0)151 666 8300
Fax: +44(0)151 666 8329
www.cbiss.com

MIR-FT Multi-gas
analyser

CO 0 to 75 mg/m3
0 to 300 mg/m3

SO2 0 to 75 mg/m3
0 to 500 mg/m3

HCl 0 to 15 mg/m3
0 to 90 mg/m3

NO 0 to 200 mg/m3
0 to 600 mg/m3

NO2 0 to 200 mg/m3
N2O 0 to 100 mg/m3
NH3 0 to 15 mg/m3
CH4 0 to 15 mg/m3
0 to 50 mg/m3
0 to 150 mg/m3

CHOH 0 to 20 mg/m3
0 to 30 mg/m3
0 to 90 mg/m3

HF 0 to 3 mg/m3
0 to 10 mg/m3

CO2 0 to 25 Vol.-%
O2 0 to 25 Vol.-%
H2O 0 to 30 Vol.-%

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
29/04/2019

Envea

Tel: +44 (0)1480 468200

PCME QAL 991
Particulate Monitor
and Sensor
(Previously named
DT-991)

Particulates 0 to 7.5 mg/m3
0 to 15 mg/m3

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
23/09/2020

Envea

Tel: +33 (0)1392 23800

CBISS Ltd (UK agent)
Tel: +44 (0)151 666 8300
Fax: +44(0)151 666 8329
www.cbiss.com

Graphite 52M FID
Analyser

TOC 0 to 15 mg/m3
TOC 0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
20/09/2021

Envea

Tel: +44 (0)1480 468200

PCME QAL 181
Particulate Analyser
(previously LMS 181)
including PCME QAL
181 SEN Sensor

Particulates  
0 to 7.5 mg/m3
0 to 15 mg/m3
0 to 100 mg/m3
0 to 200 mg/m<3

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
02/10/2020

Envea

Tel: +44 (0)1480 468200

PCME STACKFLOW
400

Velocity 0 to 30 m/s

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
24/09/2020

Envea UK Ltd

Tel: +44 (0)1480 468200

PCME QAL 260

Dust 0 to 15 mg/m3
0 to 200 SLU
0 to 500 SLU

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
14/07/2021

Envea UK Ltd

Tel: +44 (0)1480 468200

PCME STACKFLOW
200

Gas Velocity 2 to 30 m/s
2 to 50 m/s

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
23/11/2021

Envea UK Ltd

Tel: +44 (0)1480 468200

PCME QAL 360

Dust 0 to 7.5 mg/m3
0 to 10 SLU
0 to 50 SLU
0 to 100 SLU
0 to 200 SLU

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
14/07/2021

Envea GmbH

Tel: +49 8131 505 720

SM-5

Mercury(Hg)
Certification range 0 to 5 µg/m3

Suppl. ranges 0 to 30 µg/m3
0 to 45 µg/m3
0 to 100 µg/m3
0 to 1000 µg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
30/11/2022

Fer Strumenti Srl

Tel: +39 0362 231203
www.fer-strumenti.com

ENOX II AMS CEMS

NO 0 to 200ppm
0 to 2,000ppm

NOx 0 to 200ppm
CO 0 to 156ppm
0 to 2,000ppm

CO2 0 to 15 Vol.-%
SO2 0 to 1,200ppm

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
28/05/2021

Fer Strumenti Srl

Tel: +39 0362 231203
www.fer-strumenti.com

E705 AMS CEMS

O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
21/10/2021

Fer Strumenti Srl

Tel: +39 0362 231203
www.fer-strumenti.com

AMS CO-NOx-O2
with Enox 5

CO Certification range 0 to 50 mg/m3
Supplementary range 0 to 300 mg/m3

NOx* Certification range 0 to 76.7 mg/m3
Supplementary range 0 to 613.3 mg/m3

O2 Certification range 1 to 22 vol.%

*expressed as NO2 , corresponds to 0-50 mg/m3 and 0-400 mg/m3 expressed as NO, respectively

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
24/09/2021

Fives Pillard

Tel: +33 491809021

Pillard LM3086 EPA and
Pillard LM3086 SE

Dust 0 to 0.2 Ext.*
*0 to 52mg-m3
for a 5m path
length

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
11/09/2023

Fuji Electric
Co Ltd

DRM Technic Ltd
Tel: +44 (0)1782 638491

ZRE and ZRE/ZFK7
for CO, NO, SO2 and
O2

CO 0 to 125 mg/m3
0 to 1,250 mg/m3

NO 0 to 268 mg/m3
0 to 2,680 mg/m3

SO2 0 to 571 mg/m3
0 to 5,710 mg/m3

O2 0 to 25 Vol.-%
0 to 10 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
06/02/2023

Gasmet Technologies OY

Tel: +358 (0)9 7590 0400
Fax: +358 (0)9 7590 0435
www.gasmet.fi

GASMET Multi-gas
analyser
CX4000 with Oxitec
500 E SME 5 Oxygen
analyser, DX4000 &
EN4000 Multi-gas
analyser

CO 0 to 75 mg/m3
0 to 300 mg/m3
0 to 1,500 mg/m3

NO 0 to 150 mg/m3
0 to 200 mg/m3
0 to 600 mg/m3
0 to 2,000 mg/m3

H2O 0 to 30 Vol.-%
0 to 40 Vol.-%

SO2 0 to 75 mg/m3
0 to 300 mg/m3
0 to 1,500 mg/m3

HCl 0 to 15 mg/m3
0 to 90 mg/m3

NH3 0 to 15 mg/m3
0 to 50 mg/m3

NO2 0 to 200 mg/m3
0 to 500 mg/m3

N2O 0 to 100 mg/m3
0 to 500 mg/m3

CO2 0 to 25 Vol.-%
O2 0 to 25 Vol.-%
HF 0 to 3 mg/m3
0 to 10 mg/m3

CH4 0 to 15 mg/m3
0 to 50 mg/m3
0 to 150 mg/m3

CHOH 0 to 20 mg/m3
0 to 30 mg/m3
0 to 90 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
03/07/2023

Gasmet Technologies OY
Tel: +358 (0)9 7590 0400
Fax: +358 (0)9 7590 0435
www.gasmet.fi

Gasmet Continuous
Mercury Monitoring
System (CMM)

Hg 0 to 5 µg/m3
0 to 10 µg/m3
0 to 45 µg/m3
0 to 100 µg/m3
0 to 1000 µg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
10/01/2023

Gasmet Technologies OY
Tel: +358 (0)9 7590 0400
Fax: +358 (0)9 7590 0435
www.gasmet.fi

CMM AutoQAL

Hg 0 to 5 µg/m3
0 to 10 µg/m3
0 to 45 µg/m3
0 to 100 µg/m3
0 to 1000 µg/m3

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
11/06/2020

HORIBA Europe GmbH

Horiba UK Ltd
Tel: +44 (0)1604 542500

ENDA-5000 Series
Stack Gas Analysis
System

CO 0 to 50 mg/m3
0 to 500 mg/m3

NOx 0 to 100 mg/m3
0 to 1,000 mg/m3

SO2 0 to 75 mg/m3
0 to 750 mg/m3

CO2 0 to 20 Vol.-%
O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
13/12/2022

HORIBA Europe GmbH

Horiba UK Ltd
Tel: +44 (0)1604 542500

PG 350E
Multi-component
Gas Analyser

CO 0 to 75 mg/m3
0 to 6,250 mg/m3

CO2 0 to 20 Vol.-%
NOx 0 to 205 mg/m3
0 to 2,050 mg/m3

O2 0 to 25 Vol.-%
0 to 10 Vol.-%

SO2 0 to 143 mg/m3
0 to 1,430 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
24/03/2023

Kurz Instruments Inc.

Tel: +1 831-646-5911

K-BAR 2000B
Measuring System

Velocity 0 to 30 m/s

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
14/12/2020

Land Instruments
International Ltd

Tel: +44 (0)1246 417691

FGA950E, FGA950,
FGA940E, FGA940,
FGA930E, FGA930,
FGA900E, & FGA900
Flue Gas analyser

NO 0 to 200mg/m3
0 to 1,500mg/m3

CO 0 to 150mg/m3
0 to 2,500mg/m3

O2 0 to 12 Vol.-%
0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
13/02/2024

Land Instruments
International Ltd

Tel: +44 (0)1246 417691

4500 MKIII
Dust Monitor

Dust 0 to 0.2 Ext
0 to 0.1 Ext
0 to 0.4 Ext.
0 to 1.2 Ext.

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
20/10/2020

McMenon Engineering
Services Ltd

Tel. +44 (0)1946 830611

EmissionFlowGenie

Velocity 2 to 25 m/s
2 to 35 m/s

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
EN 16911-2:2013
QAL1

Version issued:
03/03/2023

NEO Monitors AS

Tel: +47 67 97 47 00
www.neomonitors.com

LaserGas II Monitor

HCl 0 to 15 mg/m3
0 to 90 mg/m3

H2O 0 to 40 Vol.-%
0 to 30 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
16/09/2022

NEO Monitors AS

Tel: +47 67 97 47 00
www.neomonitors.com

LaserGas II Monitor

Certification range
HF 0 to 1 mg/m3
Suppl. ranges
HF 0 to 3 mg/m3
HF 0 to 5 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
25/03/2024

NEO Monitors AS

Tel: +47 67 97 47 00
www.neomonitors.com

LaserGas II Monitor

NH3 0 to 10 mg/m3
0 to 15 mg/m3

H2O 0 to 40 Vol.-%
0 to 30 Vol.-%
0 to 50 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
01/06/2022

Opsis AB

Tel: +46 (0)4672 2500
www.opsis.se
www.ET.co.uk

AR 602Z (UV)
AR 650 (IR)
Used either
independently or in
combination

CO 0 to 75 mg/m3
HCl 0 to 15 mg/m3
H2O 0 to 30 Vol.-%
HF 0 to 5 mg/m3
SO2 0 to 75 mg/m3
NO2 0 to 20 mg/m3
NH3 0 to 20 mg/m3
NO 0 to 150 mg/m3
Formaldehyde
0 to 20 mg/m3
Phenol 0 to 20 mg/m3
H2O 0 to 30 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
15/03/2021

Opsis AB

Tel: +46 (0)4672 2500
www.opsis.se
www.ET.co.uk

O2000 Oxygen
Analyser

O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
15/03/2021

Opsis AB

Tel: +46 (0)4672 2500
www.opsis.se
www.ET.co.uk

AR 602Z/Hg

Hg 0 to 45 µg/m3
0 to 100 µg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
16/09/2022

Opsis AB

Tel: +46 (0)4672 2500

Enviro Technology Services plc
(UK Sales)
Email: [email protected]
Tel: +44 (0) 1453 733200
Fax: +44 (0) 1453 733201

O2000N Oxygen Analyser

O2 0-25%vol

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
14/04/2022

Protea Ltd

Tel: +44 (0)1270 872 000

www.protea.ltd.uk
[email protected]

P2000 Series
Continuous Emission
Monitor with
Protea Control Unit

CO 0 to 150 ppm
0 to 3,500 ppm

SO2 0 to 150 ppm
0 to 1,500 ppm

NO2 0 to 200 ppm
0 to 5,000 ppm

NO 0 to 240 ppm
0 to 1,500 ppm

N2O 0 to 300 ppm
0 to 5,000 ppm

CO2 0 to 15 Vol.%
0 to 25 Vol.%

H2O 0 to 30 Vol.%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/12/2023

Protea Ltd

Tel: +44 (0)1270 872 000
www.protea.ltd.uk
[email protected]

atmosFIR

NO 0 to 80 mg/m3
NO 0 to 200 mg/m3
NO2 0 to 50 mg/m3
NO2 0 to 200 mg/m3
N2O 0 to 50 mg/m3
SO2 0 to 75 mg/m3
SO2 0 to 300 mg/m3
CO 0 to 75 mg/m3
CO 0 to 300 mg/m3
HCl 0 to 15 mg/m3
HF 0 to 3.0 mg/m3
NH3 0 to 10 mg/m3
CH4 0 to 15 mg/m3
CO2 0 to 20 Vol.-%
O2 0 to 21 Vol.-%
H2O 0 to 30 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
19/01/2024

Protea Ltd

Tel: +44 (0)1270 872 000

www.protea.ltd.uk
[email protected]

atmosFID TOC analyser

TOC 0 to 15 mg/m3
0 to 30 mg/m3
0 to 150 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
cl. 7.1 CEMS
Published 20 October 2020
EN 15267
QAL1

Version issued:
29/10/2020

Rosemount, Inc.

UK Sales:
Tel: +44(0)870 240 1978

Model 6888A
Oxygen Analyser

O2 0 to 25 Vol.-%

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
16/12/2019

Rosemount, Inc.

UK Sales:
Tel: +44(0)870 240 1978

Oxymitter 4000
Oxygen Analyser
(with operator
interface LOI)

O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
01/12/2021

S.K.I Schlegel & Kremer
Industrieautomation
GmbH

Tel: 0049 2166623170
www.ski-gmbh.com

AccuFlo QAL

Certification range
Exhaust gas velocity 2 to 20 m/s

Supplementary ranges
Exhaust gas velocity 2 to 40 m/s
2 to 60 m/s

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
08/12/2022

Servomex Group Ltd

Tel: +44 (0)1892 652181

Servomex 4900
Multigas Analyser

SO2 0 to 572 mg/m3
CO 0 to 75 mg/m3
0 to 100 mg/m3

NO 0 to 268 mg/m3
0 to 650 mg/m3

O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
03/03/2022
Please note, the
N2O certification is
only valid on
instruments sold
before 10/06/2009.
Please see
certificate

for reference.

Servomex Group Ltd
Tel: +44 (0)1892 652181

SERVOFLEX MiniMP
(5200MP) Portable
Analyser

O2 0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/12/2022

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

MCS 100 E HW
Multi-Component
Analyser

SO2 0 to 75 mg/m3
NO 0 to 200 mg/m3
CO 0 to 75 mg/m3
HCl 0 to 15 mg/m3
NH3 0 to 20 mg/m3
O2 0 to 21 Vol.-%
CO2 0 to 25 Vol.-%
H2O 0 to 40 Vol.-%

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
09/08/2019

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

MCS 100 E PD
Multi-Component
Analyser

SO2 0 to 10 mg/m3
NO 0 to 50 mg/m3
NO2 0 to 80 mg/m3
CO 0 to 50 mg/m3
HCl 0 to 10 mg/m3
O20 to 21 Vol.-%
CO2 0 to 25 Vol.-%

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
09/08/2019

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

GM35 In-situ Gas
Analyser
Model Cross-Duct & GM35 In-situ Gas Analyser,
Model Measuring
Probe GMP

Cross-Duct
CO0 to 75 mg/m3
CO20 to 15 Vol.-%
H2O0 to 25 Vol.-%

GMP
CO0 to 225 mg/m3
0 to 10,240 mg/m3
CO20 to 22.5 Vol.-%
H2O0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
07/02/2022

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

SIDOR Multi Gas
Analyser with
Modules OXOR-E &
OXOR-P

CO0 to 75 mg/m3
NO0 to 125 mg/m3
SO20 to 150 mg/m3
O20 to 25 Vol.-%
0 to 10 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
21/03/2022

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

DUSTHUNTER
SP100

Dust
Certification range
0 to 7.5 mg/m3

Supplementary ranges
0 to 10 mg/m3
0 to 15 mg/m3
0 to 50 mg/m3
0 to 100 mg/m3
0 to 200 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/04/2024

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

DUSTHUNTER
SB100

Dust 0 to 100 SE
0 to 15 SE
0 to 50 SE
0 to 200 SE

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/04/2024

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

DUSTHUNTER
T200

Dust 0 to 0.1 Ext.
0 to 0.05 Ext.
0 to 0.2 Ext.
0 to 0.5 Ext.
0 to 1.0 Ext.

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/04/2024

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

GM32 In-situ
Multi-Component
Analyser
(Cross Duct Version)

Measuring path length 1.86m
NO0 to 70 mg/m3
0 to 700 mg/m3

SO20 to 75mg/m3
0 to 1,000mg/m3

Measuring path length 1.00m
NO0 to 130.2 mg/m3
0 to 1,302 mg/m3

SO20 to 139.5 mg/m3
0 to 1,860 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/04/2024

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

DUSTHUNTER
C200

Dust 0 to 0.1 Ext
0 to 0.05 Ext.
0 to 0.2 Ext.
0 to 0.5 Ext.
0 to 1.0 Ext.
0 to 50 SE
0 to 5 SE
0 to 20 SE
0 to 100 SE
0 to 200 SE

MCERTS
Performance
Standard V3.4
dated July
2012
EN15267
QAL 1

Version issued:
16/08/2019

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

DUSTHUNTER
T100

Dust 0 to 0.1 Ext
0 to 0.05 Ext.
0 to 0.2 Ext.
0 to 0.5 Ext.
0 to 1.0 Ext.

MCERTS
Performance
Standard V3.4
dated July
2012
EN15267
QAL 1

Version issued:
16/08/2019

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

GM32 In-situ
Gas Analyser
(GMP measuring
probe Version)

Measuring path length 1.25m
NO0 to 70 mg/m3
0 to 700 mg/m3

SO20 to 75mg/m3
0 to 1,000mg/m3

Measuring path length 1.00m
NO0 to 87.5 mg/m3
0 to 875 mg/m3

SO20 to 93.8 mg/m3
0 to 1,250 mg/m3

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
27/01/2020

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

MAC GMS800

CO (UNOR)0 to 75mg/m3
CO (MULTOR)0 to 200mg/m3
NO (UNOR)0 to 100mg/m3
NO (MULTOR)0 to 250mg/m3
NO (DEFOR)0 to 50mg/m3
NO2 (DEFOR)0 to 50mg/m3
NOx (UNOR)0 to 100mg/m3
SO2 (UNOR)0 to 75mg/m3
SO2 (MULTOR)0 to 250mg/m3
SO2 (DEFOR)0 to 75mg/m3
CH4 (UNOR)0 to 50mg/m3
CH2 (MULTOR)0 to 286mg/m3
N2O (UNOR)0 to 50mg/m3
CO2 (UNOR)0 to 25 Vol.-%
CO2 (MULTOR)0 to 25 Vol.-%
O2 (OXOR-P)0 to 25 Vol.-%
O2 (OXOR-E)0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN15267
QAL 1

Version issued:
21/12/2020

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

MCS 100 FT

SO2 0 to 75 mg/m3 to 0 to 300 mg/m3
NO 0 to 200 mg/m3 to 0 to 400 mg/m3
CO 0 to 75 mg/m3 to 0 to 300 mg/m3
HCl 0 to 15 mg/m3 to 0 to 90 mg/m3
HF 0 to 3 mg/m3 to 0 to 90 mg/m3
TOC 0 to 15 mg/m3 to 0 to 50 mg/m3
NH3 0 to 10 mg/m3 to 0 to 50 mg/m3
H2O 0 to 40 Vol.-%
NO2 0 to 100 mg/m3
N2O 0 to 50 mg/m3
CH4 0 to 50 mg/m3
O2 0 to 21 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN15267
QAL 1

Version issued:
21/12/2020

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

GMS810 / 811 GMS840 –
FIDOR TOC analyser

TOC 0 to 15 mg/m3
0 to 50 mg/m3
0 to 150 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
04/02/2022

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

MERCEM300Z
Mercury Monitoring
System

Hg 0 to 10 µg/m³
0 to 45 µg/m³

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
12/01/2024

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

FWE200DH
Dust Monitor

Dust 0 to 7.5 mg/m3
0 to 15 mg/m3
0 to 20 SE
0 to 50 mg/m3
0 to 100 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/04/2024

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

ZIRKOR200

O20 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
21/03/2022

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

GM32 LowNOx GMP

SO2 0 to 75 mg/m3 x m
SO2 0 to 1,000 mg/m3 x m
SO2 0 to 2,500 mg/m3 x m

NO 0 to 70 mg/m3 x m
NO 0 to 700 mg/m3 x m
NO 0 to 1,302 mg/m3 x m

MCERTS
Performance
Standard V4
dated July
2018
EN15267
QAL 1

Version issued:
29/08/2019

SICK AG

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

MCS200HW/MCS200HW Ex

CO 0 to 75 mg/m3
0 to 10,000 mg/m3

NO 0 to 150 mg/m3
0 to 2,500 mg/m3

NO2 0 to 50 mg/m3
0 to 500 mg/m3

N2O 0 to 100 mg/m3
0 to 2000 mg/m3

SO2 0 to 75 mg/m3
0 to 2,500 mg/m3

HCl 0 to 15 mg/m3
0 to 3,000 mg/m3

NH3 0 to 10 mg/m3
0 to 500 mg/m3

CH4 0 to 50 mg/m3
0 to 500 mg/m3

CO20 to 25 Vol.-%
H2O 0 to 40 Vol.-%
O2 0 to 25 Vol.-%
TOC0 to 15 mg/m3
0 to 50 mg/m3
0 to 150 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
20/03/2024

SICK Engineering GmbH

International Sales:
Tel: 0049 76414690
Fax: 0049 76414691149

UK Sales:
Tel: 01727 831121
Fax: 01727 845644

FLOWSIC100 Gas
Flowmeter

Velocity 0 to 20 m/s
0 to 40 m/s

MCERTS
Performance
Standard V3.4
dated July
2008
EN15267
QAL 1

Version issued:
09/08/2019

Siemens AG

Siemens Process Analytics
Tel: +44 (0)1905 450500

OXYMAT 6
Oxygen analyser

O2 0 to 5 Vol.-%
0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/02/2024

Siemens AG

Siemens Process Analytics
Tel: +44 (0)1905 450500

ULTRAMAT 23
Multi-component gas
analyser

SO20 to 400 mg/m3
NO0 to 100 mg/m3
0 to 250 mg/m3
0 to 400 mg/m3
0 to 750 mg/m3

CO0 to 150 mg/m3
0 to 250 mg/m3

O20 to 10 Vol.-%
0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/02/2024

Siemens AG

Siemens Process Analytics
Tel: +44 (0)1905 450500

ULTRAMAT 6
Multi-component gas
analyser

SO2 0 to 75 mg/m3
NO 0 to 100 mg/m3
0 to 200 mg/m3

CO 0 to 50 mg/m3
0 to 75 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/02/2024

Siemens AG

Siemens Process Analytics
Tel: +44 (0)1905 450500

ULTRAMAT/OXYMAT
6
Multi-component gas
analyser

SO2 0 to 75 mg/m3
NO 0 to 100 mg/m3
0 to 200 mg/m3

CO 0 to 50 mg/m3
0 to 75 mg/m3

O2 0 to 5 Vol.-%
0 to 25 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/02/2024

Siemens AG

Siemens Process Analytics
Tel: +44 (0)1905 450500

LDS 6 Ammonia
Analyser

NH3 0 to 20 mg/m3
0 to 76 mg/m3
0 to 380 mg/m3

H2O 0 to 30 Vol.-%
0 to 40 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/11/2021

Siemens AG

Siemens Process Analytics
Tel: +44 (0)1905 450500

LDS 6 HCl Analyser

HCl 0 to 15 mg/m3
0 to 90 mg/m3

H2O 0 to 30 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/11/2021

Siemens AG

Tel: +44 (0)1905 450500

SIPROCESS UV600

NO 0 to 50 mg/m3
NO20 to 50 mg/m3
SO2 0 to 75 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN15267
QAL 1

Version issued:
18/01/2021

Siemens AG

Siemens Process Analytics
Tel: +44 (0)1905 450500

SET CEM CERT

CO 0 to 75 mg/m3
0 to 200 mg/m3
0 to 250 mg/m3
0 to 1,000 mg/m3
0 to 1,250 mg/m3

NOx 0 to 150 mg/m3
0 to 230 mg/m3
0 to 400 mg/m3
0 to 613 mg/m3

NO 0 to 50 mg/m3
0 to 100 mg/m3
0 to 600 mg/m3
0 to 1,000 mg/m3

NO2 0 to 50 mg/m3
0 to 1000 mg/m3

SO2 0 to 70 mg/m3
0 to 75 mg/m3
0 to 400 mg/m3
0 to 1,250 mg/m3

CO2 0 to 25 Vol.-%
0 to 30 Vol.-%

O2 0 to 25 Vol.-%
0 to 5 Vol.-%

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
19/03/2021

Siemens AG

Siemens Process Analytics
Tel: +44 (0)1905 450500

FIDAMAT 6

TOC 0 to 15 mg/m3
0 to 50 mg/m3
0 to 150 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
23/11/2022

Siemens AG

Siemens Process Analytics
Tel: +44 (0)1905 450500

FIDAMAT 6 Measuring System II

TOC 0 to 15 mg/m3
0 to 50 mg/m3
0 to 150 mg/m3
0 to 500 mg/m3
0 to 3000 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
22/12/2022

Sintrol Oy

Tel: +358 9 5617 360

S305QAL Dust Monitor

Certification range
Dust 0 to 7.5 mg/m3

Supplementary ranges
Dust 0 to 15 mg/m3
0 to 100 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
21/05/2021

SK-Elektronik GmbH

Tel: +49 2171 39550

UPAS-FID ES

TOC 0 to 15 mg/m3
0 to 30 mg/m3
0 to 100 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267-1, EN 15267-2, EN 15267-3
QAL1

Version issued:
23/11/2020

SK-Elektronik GmbH
(Formerly Meß &
Analysentechnik GbmH)

Tel: +49 2171 39550

Thermo-FID TOC
Analyser
(Model PT, FE, ES,
TG, MK & KA)

TOC 0 to 15 mg/m3
0 to 30 mg/m3
0 to 2,000 mg/m3

MCERTS
Performance
October 2020
EN15267
QAL 1

Version issued:
02/10/2020

Testa GmbH

Tel: 004989-1293005

www.testa-fid.de

iFiD Rack

TOC 0 to 15 mg/m3
0 to 30 mg/m3
0 to 150 mg/m3
0 to 500 mg/m3

Environment Agency Guidance
“MCERTS for stack emissions monitoring equipment at industrial installations”
– Continuous emissions monitoring systems (CEMS)
Published 20 October 2020
EN 15267
QAL1

Version issued:
09/06/2023